Doc. Title
ST3940 User Manual
Concerning:
Rev.
Date (dd-mm-yy)
Page of Pages
Features and how to configure ST3940
1.06
0
18-6-19
35 of 54
by “=” .Max value = “999999999”
<Example>
[command]
ST600CMD;0123456789;02;SetDist=100
[response]
ST600CMD;Res;0123456789;309;SetDist
10-3. Command on how to initialize Message Number
This command is used if you want to initialize sequence number of the message.
Field
Mark
Value
Meaning
CMD_ID
“InitMsgNo”
Set message number to 0.
<Example>
[command]
ST600CMD;0123456789;02;InitMsgNo
[response]
ST600CMD;Res;0123456789;309;InitMsgNo
10-4. Command on how to initialize Circular Geo-fence
● This command is used for erasing all circular geo-fence setting data.
Field
Mark
Value
Meaning
CMD_ID
“InitCircleGeo”
Erase all circular geo-fence data.
<Example>
[command]
ST600CMD;0123456789;02;InitCircleGeo
[response]
ST600CMD;Res;0123456789;309;InitCircleGeo
10-5. Command on how to request data relating to Circular Geo-fence
This command is used if the device is required to report to the server with all of the geo-fence parameters that are pre-
set.