6
Sunstone Welders -
AC Welder User Manual
WELDER INTERFACE
1.
POWER ON
– The power on will light up anytime the welder is plugged-in to an appropriate VAC source .
2.
WELD GO
– The weld go will light up anytime the weld trigger is active and the unit is welding .
3.
SINGLE/REPEAT
– This controls the mode of operation for the welder . Selecting single will result in
one weld per trigger actuation . Repeat will allow the welder to make multiple welds, as long as the
trigger is engaged (foot pedal is depressed) .
4.
WELD ON/WELD OFF
– Selecting weld off will disable the welder from performing welds .
5.
WELD CYCLES
– This switch gives the ability to use the normal weld cycles or to cut the cycles in half .
The cycles are set using the cycle knobs on the bottom of the front panel . Using a half cycle gives
additional refinement when setting up the weld.
6.
REST
– This knob controls the rest time between pulses . Setting the knob to “0” will set the machine in
Seam Mode .
7.
WELD
– This knob controls the weld cycles, or how long the energy is released .
8.
POWER
– This knob controls the power as a percentage of total power, ranging from 40% - 100% .
9.
POWER RANGE
– This is available on the 5 .0kVA model . The 5 .0kVA model has 4 power ranges to
choose from . Power range 1 is for lower powered welds; power range 4 is for higher powered welds .