6.14 BOOSTER PUMP
Additional pump that fi lls the system at the start of every solar charge.
Settings range: S1-S8, VFS1-2, Active storage/ Default setting: none
Time the pump is switched on
This setting determines the length of time the pump is switched on at the start of a solar charge.
Settings range: 0-120 seconds / Default setting: 30 seconds
6.14.1 Filling Time
6.15 PARALLEL OPERATION R (X)
The relais is switched on at the same time as the set relay R1 or R2.
Settings range: On, Off
This menu determines how long after the start of R1 or R2 the parallel relay is switched on.
Settings range: 0-120 seconds / Default setting: 30 seconds
6.15.1 Delay
This menu determines how long after the switch off of R1 or R2 the parallel relay is switched off.
Settings range: 0-120 seconds / Default setting: 30 seconds
6.15.2 Followup Time
6.16 ALWAYS ON
Relay is always switched on.
6.17 HEATING CIRCUIT
Heat circuit pump is controlled with a fi xed hysteresis of (+/-1° for setpoint temperature). 30 seconds Switch on and Switch off delay is fi xed set
-
ting to prevent unnecessary switching of the pump. RC21 room controller can be used as room temperature sensor.
Settings range: On, Off
This menu determines how long after the start of R1 or R2 the parallel relay is switched on.
Settings range: 0-120 seconds / Default setting: 30 seconds
6.15.1 Delay