5.8
Communication Wiring Board
The communication board of the inverter includes two layers. The upper layer
communication board mainly includes RS485 communication interfaces while the lower
layer communication board mainly includes DI/DO interface and DRM interface.
5.9
RS485 Communication
5.9.1 Interface Description
As shown in the Figure below, the inverter is equipped with three RS485 communication
interfaces and one dip switch.
All three interfaces can be connected to a data acquisition device (Data Logger), to
achieve data exchange with PC or other monitoring devices.
The RS485-1 crimp and the RJ45 interface can be applied to applications where
multiple inverters communicate in a daisy-chain form.