SUNFAR C300 25
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code
Name
Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F2.7
External freq. set time
constant offiltering
0.01
~
1.00Sec 0.01
0.10
F2.8
Combination setting mode
Refer to the explanations about
(
0
~
19
)
1 0
F2.9
Analog output selection
(
AVO
)
The first part of LED (form right to left)
:
AO1output
0
:
Output freq.
1
:
Output current
2
:
Output voltage
3
:
Rotational speed Of applied motor
4
:
PID setting
5
:
PID feedback
The second and third and fourth part of
LED
:
Reserved
1 0000
F2.10
The lower limit of analog
output AVO
0.0
~
[F2.11] 0.1
0.0
V
F2.11
The upper limit of analog
output AVO
[F2.10]
~
12.0 0.1
10.0V
A
nalo
g
I/
O p
aram
e
te
r u
n
it
F2.12 Reserved
--
-- --
--
-- --
--