SUNFAR C300 101
C300 series of non-sensor current vector-control inverter manual
Slave responding
Sending Sequence
0
Header
9
Running data
1
Slave addr.
10
Running data
2
Slave addr.
11
Running data
3
Slave responding
12
Running data
4
State feedback
13
Check sum
5
State feedback
14
Check sum
6
0
15
Check sum
7
Data subentry
16
Check sum
8
Data subentry
17
Tail
Data subentry is state monitor parameters, shown as following table.
Monitor item
Data subentry
Returning data form slave
d-0 00
Output
frequent
d-1 01
Output
current
.
.
.
.
.
.
.
.
.
d-15 15
External
pulse
input
.
.
.
.
.
.
.
.
.
d-37
37
Temperature of module of last fault
(
3
)
Order
is read parameters of code.
Ⅲ
0 1 2
3 4 5
6 7 8
9 10
11
12
13
Master
Sending
Header
Subordi
nation
addr.
Subordi
nation
addr.
2
Operation
order
Operation
order
Data
type
Data
Addr.
Data
Addr.
Check
sum
Check
sum
Check
sum
Check
sum
Tail
Slave responding
Sending Sequence
0
Header
9
Parameter data
1
Slave addr.
10
Parameter data
2
Slave addr
11
Parameter data
3
Slave responding
12
Parameter data
4
State feedback
13
Check sum
5
State feedback
14
Check sum
6 Data
type
15
Check sum
¾
Refer to the explanation about state monitor parameter in the fourth chapter.