![Sundyne LMV-803Lr Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/sundyne/lmv-803lr/lmv-803lr_installation-operation-and-maintenance-manual_1395690025.webp)
Installation and Operation Manual
SA-07-11-87, Rev A
20
January 2019
Moving the LMV-803Lr
Moving (OH5 Configuration)
The following procedures apply to the direct drive (OH5) configuration of the LMv-803Lr. Where indicated,
separate instructions for the extended shaft motor and bearing box configurations are called out.
1.01 Remove the (6) seal housing nuts located
closest to the inlet and discharge as shown
below. Place two lifting brackets over each
of the studs (each bracket is unique, and
must go on the correct side). Correct
locations will have the brackets parallel to
the pump case flange faces. Bolt the lifting
brackets to the seal housing using the (6)
seal housing nuts finger tight. DO NOT
TORQUE THE LIFTING BRACKET NUTS
YET.
Note:
Lifting Brackets are included with the
OH5 (Direct Drive) units. Brackets
are not required with OH3 (Bearing
Box) configurations.
NOTE:
Motor / Bearing Box / Cartridge Seal
not shown for clarity.
1.02 Install the Lifting Hanger using (2)
bolts/nuts per side. Tighten each size.
With the Lifting Hanger securely bolted to
the Lifting Brackets, tighten the Lifting
Bracket nuts onto the pump case studs.
NOTE:
Motor / Bearing Box / Cartridge Seal
not shown for clarity.