Servicing CRUs That Do Not Require Server Power-Off
57
▼
Remove a Power Supply
1. Identify which power supply requires replacement.
A lit amber Service Required LED on a power supply indicates that a failure was
detected. You can also use the Oracle ILOM
show faulty
command at the Oracle
ILOM prompt (->) to identify a power supply failure.
Alternatively, to list all known faults in the server, log into the Oracle Solaris OS
and issue the fmadm faulty command, or log into the Oracle ILOM service
processor from the Oracle ILOM Fault Management Shell and issue the fmadm
faulty command.
Note –
The fans of a failed power supply might still be spinning when the system is
powered on. You can remove a power supply while the fans are still spinning.
2. Gain access to the rear of the server where the faulty power supply is located.
3. If the cable management arm (CMA) is installed, disconnect both CMA left-side
connectors and move the CMA out of the way.
For instructions for disconnecting the CMA left-side connectors, see the
Sun Server
X4-2 Installation Guide,
“Remove the Second-Generation Cable Management Arm”
on page 64
or
Sun Server X4-2 Installation Guide,
“Install the First-Generation Cable
Management Arm” on page 69
as applicable.
TABLE:
Server Power Supply Indicators
Legend
Status
Indicator
Name
Icon
Color
State Meaning
1
AC OK/DC
OK
Green
• OFF – No AC power is present.
• SLOW BLINK – Normal operating. Input
power is within specification. DC output
voltage is not enabled.
• STEADY ON – Normal operation. Input AC
power and DC output voltage are within
specification.
2
Service
Required
Amber
• OFF – Normal operation; no service required.
• STEADY ON – The power supply (PS) has
detected a PS fan failure, PS overtemperature,
PS over current, or PS over/under voltage.
Содержание Sun Server X4-2
Страница 1: ...Sun Server X4 2 Service Manual Part No E38041 07 May 2014...
Страница 14: ...xiv Sun Server X4 2 Service Manual May 2014...
Страница 34: ...20 Sun Server X4 2 Service Manual May 2014...
Страница 42: ...28 Sun Server X4 2 Service Manual May 2014 Returning the Server to Operation on page 143...
Страница 125: ...Servicing FRUs 111 FIGURE Removing a Processor Related Information Install a Processor on page 112...
Страница 166: ...152 Sun Server X4 2 Service Manual May 2014...
Страница 174: ...160 Sun Server X4 2 Service Manual May 2014...
Страница 210: ...196 Sun Server X4 2 Service Manual May 2014...
Страница 232: ...218 Sun Server X4 2 Service Manual May 2014...
Страница 270: ...256 Sun Server X4 2 Service Manual May 2014...
Страница 276: ...262 Sun Server X4 2 Service Manual May 2014...