146
Sun Server X4-2 Service Manual • May 2014
FIGURE:
Installing the Top Cover
5. Close the server fan door.
6. Remove the antistatic precautions.
See
“Remove Antistatic Measures” on page 146
.
Related Information
■
“Remove the Server Top Cover” on page 43
■
“Remove Antistatic Measures” on page 146
▼
Remove Antistatic Measures
1. Remove any antistatic straps or conductors from the server chassis.
2. Remove the antistatic wrist strap from yourself.
▼
Reinstall the Server Chassis Into the
Rack
If you removed the server chassis from the rack, perform these steps to reinstall it.
Caution –
Deploy any rack anti-tilt mechanisms before installing the server into the
rack.