b. Install the HDDs 4-7 cable connector into the top disk backplane [2].
c. Plug the HDDs 4-7 cable connector into the connector on the right side of the
HBA card (the connector that is closest to the power supplies) [3].
5. Install the PCIe riser with the internal HBA card into PCIe slot 3.
See
“Install a PCIe Riser Into PCIe Slots 3 and 4” on page 82
.
6. Install all of the server fan modules.
See
“Install a Fan Module” on page 54
.
7. Return the server to operation.
a. Install the server top cover.
See
“Install the Server Top Cover” on page 145
.
b. Close the server fan door.
c. Return the server to the normal rack position.
See
“Return the Server to the Normal Rack Position” on page 148
.
d. Reconnect the data cables to the server and reconnect the power cords to the
server power supplies.
See
“Reconnect Data Cables and Power Cords” on page 149
.
e. Power on the server.
See
“Power On the Server” on page 150
.
Verify that the Power/OK status indicator is steady on.
Related Information
■
“Remove Storage Drive SAS Cables” on page 139
Содержание Sun Server X4-2
Страница 1: ...Sun Server X4 2 Service Manual Part No E38041 07 May 2014...
Страница 14: ...xiv Sun Server X4 2 Service Manual May 2014...
Страница 34: ...20 Sun Server X4 2 Service Manual May 2014...
Страница 42: ...28 Sun Server X4 2 Service Manual May 2014 Returning the Server to Operation on page 143...
Страница 125: ...Servicing FRUs 111 FIGURE Removing a Processor Related Information Install a Processor on page 112...
Страница 166: ...152 Sun Server X4 2 Service Manual May 2014...
Страница 174: ...160 Sun Server X4 2 Service Manual May 2014...
Страница 210: ...196 Sun Server X4 2 Service Manual May 2014...
Страница 232: ...218 Sun Server X4 2 Service Manual May 2014...
Страница 270: ...256 Sun Server X4 2 Service Manual May 2014...
Страница 276: ...262 Sun Server X4 2 Service Manual May 2014...