12
Sun Blade 6048 Modular System Product Notes • April 2011
Power Supply Watt Meter Feature Not Available
for A231 Power Supplies (6614183)
For a chassis that has A231 power supplies installed, the ILOM power meter feature
is not currently available.
Power Consumption Is Invalid in ILOM if PSU
Side Is Under 25A (6438921)
This could result in missing information in the ILOM CLI and web interface. The
following readings will occur if the power supply current is < 25 Amps:
■
If any side of a installed power supply unit (PSU) is drawing < 25 Amps of
current, the
ch.dc_watts
and
ch.ac_watts
IPMI sensors will show "disabled"
when viewed with ipmitool.
■
The IPMI sensors
ps
x
.dc_watts
,
ps
x
.ac_watts
and
ps
x
.peff
will also show
"disabled"; where
x
is the PSU that has a side drawing < 25 Amps.
■
If any of the above conditions are true, such that chassis watts cannot be
calculated, actual power cannot be calculated.
You will get the following output when you type the
show
command in CLI:
show /CMM/powermgmt
actual_power = (none)
You can determine the amount of current a PSU side is drawing by reading the
psX.I12V_Z sensor; where x=0..1 (PSU) and
z
=0..1 (PSU side) for A206 PSUs and x=
0..1 (PSU) and
z
=0..3 (PSU side) for A231 PSU.
If using the CLI, you can determine the amount of current a PSU is drawing by
typing:
show /CH/PS
x
/Sy/I_12V
Where
x= 0..1
. (PSU) and with A206 model PSUs,
y = 0..1
(PSU side) and with A231
PSUs
y = 0..2
(PSU side).
Содержание Sun Blade 6048
Страница 1: ...Sun Blade 6048 Modular System Product Notes Part No E23072 01 April 2011...
Страница 12: ...4 Sun Blade 6048 Modular System Product Notes April 2011...
Страница 39: ...Chapter 3 ILOM Notes and Issues 31...
Страница 40: ...32 Sun Blade 6048 Modular System Product Notes April 2011...
Страница 42: ...34 Sun Blade 6048 Modular System Product Notes April 2011...