23
The following algorithm is also applied to the fan actions. Starting from number 1 in
the list, the first condition that is true determines the fan speeds:
1. If at least one blade is at a critical temperature level, then blast fans.
2. If at least one blade is at a hot temperature level, then fan speeds increase.
3. If at least one blade is at a cool temperature level, then fan speeds are lowered
4. If at least one blade is at normal level, then fans are held at current speed.
5. If none of the preceding conditions are true, the blades are powered off, so the
fans are turned off.
CMM
permitted_power
Error Message is Unclear
(6863970)
This issue was fixed in ILOM 3.0.10.
When the blade is already powered on, you should not be able to set its
permitted_power
to a value lower than what is currently already allocated to it.
The error message that appears on both the CLI and web interface when you
attempt to allocate a lower power value should be more descriptive of the reason
why the power level is not permitted.
start /CH
or
start /CH/NEM
x Does Not Warn That
Target Is Already Started (6867739)
This issue was fixed in ILOM 3.0.10.
When trying to start a target that has already been started, the following message
should appear:
start: Target already started
This message does not appear when
start /CH
or start
/CH/NEM
x is attempted
when the target has already been started.
Содержание Sun Blade 6048
Страница 1: ...Sun Blade 6048 Modular System Product Notes Part No E23072 01 April 2011...
Страница 12: ...4 Sun Blade 6048 Modular System Product Notes April 2011...
Страница 39: ...Chapter 3 ILOM Notes and Issues 31...
Страница 40: ...32 Sun Blade 6048 Modular System Product Notes April 2011...
Страница 42: ...34 Sun Blade 6048 Modular System Product Notes April 2011...