Chapter 3
ILOM Notes and Issues
27
ILOM CMM SP Does Not Display Current Status
Information (6516108)
This issue was fixed in ILOM 3.0.3.32.
The ILOM CMM service processor does not report current detailed power supply or
fan status information.When a PSU fan is removed, the CLI and IPMItool does not
report this change. To determine fan or power supply status information, you should
check the following objects:
■
/CH/PS
x
/V*
■
/CH/PS
x
/V_12V_MAIN
■
/CH/PS
x
/FAN_FAIL
/CH/LOCATE Does Not Turn Off When Set to ON
Using the ILOM CLI or ipmitool (6695802)
This issue was fixed in ILOM 3.0.3.32.
/CH/LOCATE does not turn off when set to ON/Fast_Blink using ipmitool or CLI.
However, when the chassis Locate LED button is pressed, it times out and goes off
after 30 minutes as expected.
Locate LED Does not Turn on During Chassis Lamp Test
(6713569, 6711416)
This issue was fixed in ILOM 3.0.3.32.
When running ILOM 2.0.3.3, if you press the locate button more than 5 seconds to
initiate the lamp LED test, the LED does not turn on and a “
transition to
degraded
” message appears in the SEL log.
SP Reports Incorrect FM, NEM, and Server Module
Removal and Insertion Events (6744044)
This issue was found in ILOM 2.0.3.10 and fixed in ILOM 3.0.3.32.
The SP reports fan module (FM), network express module (NEM), and server
module blade (BL) removal and insertion event logs repeatedly, though no insertion
or removal has taken place.
Содержание Sun Blade 6048
Страница 1: ...Sun Blade 6048 Modular System Product Notes Part No E23072 01 April 2011...
Страница 12: ...4 Sun Blade 6048 Modular System Product Notes April 2011...
Страница 39: ...Chapter 3 ILOM Notes and Issues 31...
Страница 40: ...32 Sun Blade 6048 Modular System Product Notes April 2011...
Страница 42: ...34 Sun Blade 6048 Modular System Product Notes April 2011...