(Continuation)
8. Netmask section - Accepts the netmask for the private SCI
sub-nets.
For
example,
a cluster with less than 15 hosts
per switch should select a netmask of 0xf0 while
a
cluster
with
15
hosts
or more but less than 31 hosts would choose
0xe0.
A sample template for this section -
Netmask = f0
USAGE
The root user can start
sm_config
from
the
command
line
using the -f option to provide an input file to it.
A cluster can have 3 topologies -
(i) Switched - All hosts are connected to
each
other
via
SCI switches.
Can have 2 or more hosts.
(ii) Non-switched - Two hosts connected
directly
via
SCI
cables (direct links).
Has exactly 2 hosts.
(iii) Hybrid - Contains switches and direct links. Can have
2 or more hosts.
NOTE - At this point, PDB does not
support
more
than
two
switches
in
a cluster (see (i) above), nor does it support
case (iii) from above.
NOTE - sm_config can be run on any host in the cluster,
but
it
should
not
be run on multiple hosts simultaneosly (eg.
via cconsole).
If this occurs, the results
are
unpredict-
able - in the worst case, the adapter flash memory might get
programmed with corrupt data.
NOTE
-
After
running
sm_config,
the
system
should
be
rebooted.
FILES
/opt/SUNWcluster/bin/sm_config
/etc/sma.config
/etc/sma.ip
SEE ALSO
sm_configd(1M)
DIAGNOSTICS
sm_config prints error and warning messages to stderr.
If a
fatal error occurs on any host or locally where sm_config is
running, then the process is aborted and no
/etc/sma.config
is
generated
till
the error is rectified.
Do not reboot
the machine till a successful run of sm_config has been com-
pleted.
RELEASE NOTES -
If nis+ is being used as the name service then
the
default
behaviour
is
to
look
up
the global nis+ map but if that
doesn’t exist, the local /etc/services file is not searched.
This
behaviour is different from the default nis behaviour.
In
this
scenario
inetd
will
be
unable
to
start
the
(continued)
46
Sun HPC 3.0 SCI Guide
♦
June 1999, Revision A
Содержание Sun HPC 3.0
Страница 6: ...vi Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 16: ...Figure 1 4 Supported Four Node SCI Interconnections 6 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 20: ...10 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 25: ...Figure 2 2 Examples of Three Node Switched SCI Connections Network Connection Procedure 15...
Страница 26: ...Figure 2 3 Examples of Four Node SCI Switched Connections 16 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 40: ...30 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 60: ...50 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 67: ...Continuation msgstr Not Available msgid SUNWcluster sma smactl 4008 fix msgstr Not Applicable SMA Messages 57...