General Switch Status LED
The switch status LED located on the rear panel indicates overall switch failures
(Table 6–2).
TABLE 6–2
SCI Switch Rear Panel LED
Situation
LED Status
Fatal switch errors:
fatal hardware error,
temperature too high,
fan(s) not operative,
power supply problem
Red
Switch operational
Green
The
get_ci_status
Command
You can use the results of the
get_ci_status
command to troubleshoot clusters
that have SCI switches. For example, for the configuration in Figure 6–2, if the
get_ci_statu
s command is used on interconn1, a typical output would be:
# /opt/SUNWsma/bin/get_ci_status
sma: sci #0: sbus_slot# 1; adapter_id 8 (0x08); ip_address 1; switch_id# 0; port_id# 0; Adapter Status - UP; Link Status
UP
sma: Switch_id# 0
sma: port_id# 1: host_name = interconn2; adapter_id = 72; active | operational
sma: port_id# 2: host_name = interconn3; adapter_id = 136; active | operational
sma: port_id# 3: host_name = interconn4; adapter_id = 200;inactive|inoperational
#
In this example, the line
sma: port_id# 3: host_name = interconn4; adapter_id = 200;inactive|inoperational
indicates that the path between SCI switch 0, port 3 and interconn4 is inactive and
not operational.
SCI Interface Troubleshooting
39
Содержание Sun HPC 3.0
Страница 6: ...vi Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 16: ...Figure 1 4 Supported Four Node SCI Interconnections 6 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 20: ...10 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 25: ...Figure 2 2 Examples of Three Node Switched SCI Connections Network Connection Procedure 15...
Страница 26: ...Figure 2 3 Examples of Four Node SCI Switched Connections 16 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 40: ...30 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 60: ...50 Sun HPC 3 0 SCI Guide June 1999 Revision A...
Страница 67: ...Continuation msgstr Not Available msgid SUNWcluster sma smactl 4008 fix msgstr Not Applicable SMA Messages 57...