Sun Microsystems, Inc.www.sun.com
Submit comments about this document at:
http://www.sun.com/hwdocs/feedback
Sun Fire
™
X2250 Server
Installation Guide
Part No. 820-4591-10, Rev. AMay 2008
Страница 1: ...Sun Microsystems Inc www sun com Submit comments about this document at http www sun com hwdocs feedback Sun Fire X2250 Server Installation Guide Part No 820 4591 10 Rev A May 2008...
Страница 2: ...150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc d tient les droits de propri t intellectuels relatifs la technologie incorpor e dans le produit qui...
Страница 3: ...Cables 4 To Connect the Cables 4 Powering On and Off the Server 5 To Apply Standby Power for Initial Service Processor Configuration 6 To Power On Main Power Mode 7 To Power Off Main Power Mode 7 Setu...
Страница 4: ...IP Addresses Using the BIOS Setup Utility 23 Setting Up Platform Operating System and Driver Software 24 Installing Other Operating Systems and Drivers 24 3 Configuring the Preinstalled Solaris 10 Ope...
Страница 5: ...ed Solaris Operating System Using UNIX Commands This document might not contain information about basic UNIX commands and procedures such as shutting down the system booting the system and configuring...
Страница 6: ...eaning Examples AaBbCc123 The names of commands files and directories on screen computer output Edit your login file Use ls a to list all files You have mail AaBbCc123 What you type when contrasted wi...
Страница 7: ...r 820 4590 PDF Print Sun Fire X2250 Server Installation Guide Detailed installation information for setting up the server 820 4591 PDF HTML Print option Sun Fire X2250 Server Operating System Installa...
Страница 8: ...PDF HTML Sun Fire X2250 Server Safety and Compliance Manual Hardware safety and compliance information for the server 820 4595 PDF Important Safety Information for Sun Hardware Systems Multilingual h...
Страница 9: ...ble or liable for any content advertising products or other materials that are available on or through such sites or resources Sun will not be responsible or liable for any actual or alleged damage or...
Страница 10: ...x Sun Fire X2250 Server Installation Guide May 2008...
Страница 11: ...e Rails on page 3 Connecting the Cables on page 4 Powering On and Off the Server on page 5 Setup Troubleshooting and Support on page 8 Safety and Compliance Information Refer to the following document...
Страница 12: ...em Install additional components Install additional components Yes No See Package Contents Inventory on page 3 To install additional components see the Sun Fire X2250 Server Service Manual or the comp...
Страница 13: ...o a four post rack using the orderable slide rail and cable management arm options Detailed instructions can also be found online in the Sun Fire X2250 Server Service Manual 820 4593 at the following...
Страница 14: ...URE 1 2 and TABLE 1 1 for the locations of the connectors To Connect the Cables Connect the server and external devices as follows 1 Connect a serial null modem cable to the serial port The default se...
Страница 15: ...rocessor Procedures for powering on to main power mode and for shutting down from main power mode are also included in this section for your reference TABLE 1 1 Back Panel Label Connector Slot Label C...
Страница 16: ...nisms 1 Connect a grounded AC power cord to the AC power connector on the back panel of the server and to a grounded AC power outlet In standby power mode the Power OK LED on the front panel flashes i...
Страница 17: ...tton lights and remains lit Note The first time the server powers on the power on self test POST can take up to a minute to complete To Power Off Main Power Mode To power off the server from main powe...
Страница 18: ...all outlet have power Test by plugging in another device CD or DVD does not eject from the media tray when you press the Eject button Move the mouse or press any key on the keyboard The drive might be...
Страница 19: ...in low power mode but the Power OK LED does not blink The Power OK LED only blinks when all server components are in low power mode A tape drive might be connected to your server Because tape drives...
Страница 20: ...r Peripherals attached to the system Email address and phone number for you and a secondary contact Street address where the system is located Superuser password Summary of the problem and the work be...
Страница 21: ...sun com handbook_pub SunServiceSM support phone numbers 1 800 872 4786 1 800 USA 4Sun select Option 1 International telephone numbers for SunService support http www sun com service contacting solutio...
Страница 22: ...12 Sun Fire X2250 Server Installation Guide May 2008...
Страница 23: ...Manager software This chapter contains these topics Introduction to the Integrated Lights Out Manager on page 14 Connecting to the ILOM Service Processor on page 16 Setting Up Platform Operating Syste...
Страница 24: ...mware is operating system independent These firmware applications provide the following system management interfaces into your server A web based graphical interface A Secure Shell SSH command line in...
Страница 25: ...P through a remote Secure Shell SSH you must install a Secure Shell communications application on the remote client system server workstation or laptop Many Secure Shell communications applications ar...
Страница 26: ...u can perform initial configuration of ILOM Note This procedure assumes that you have already completed the hardware setup and have applied standby power to your server as described in Chapter 1 1 Ver...
Страница 27: ...Once you have successfully logged in the SP displays its default command prompt You can now run CLI commands to configure ILOM for the server s user accounts network settings access lists alerts and o...
Страница 28: ...assumes that you have already completed the hardware setup and have applied standby power for your server as described in Chapter 1 1 Verify that your DHCP server is configured to accept new media ac...
Страница 29: ...administrator to locate the correct path to the log file c Identify the IP address in the log file that corresponds to the MAC address of your ILOM SP Typically DHCP log file entries are individual li...
Страница 30: ...d enter it as shown in FIGURE 2 3 The first web page prompts you for the default username root and the default password changeme FIGURE 2 3 Opening a Session With a Web Interface 5 After you have ente...
Страница 31: ...ss of the ILOM SP from one of the following locations CLI command The SP has a serial port to which you can attach a terminal device If you log in to the SP and enter the CLI command show SP network t...
Страница 32: ...H connection to the ILOM CLI type the appropriate connection command in the SSH application For example to connect to the SP with the DHCP assigned IP address of 129 144 82 20 you would type the follo...
Страница 33: ...AN Configuration screen select IP Address 6 From the IP Address screen select IP Address Mode 7 On the IP Address Mode screen select Static 8 Type the static IP address in the IP Address field Click E...
Страница 34: ...manually install and configure a supported Solaris Windows or Linux OS on your server Refer to the Sun Installation Assistant for Windows and Linux User s Guide for information on using the Sun Instal...
Страница 35: ...in configuring the preinstalled OS you need to do the following 1 Perform initial configuration of the server s Integrated Lights Out Manager ILOM service processor SP and determine the server s netwo...
Страница 36: ...t you are using from the list of available terminal types Network connection Is the system connected to a network Networked Non networked DHCP Can the system use Dynamic Host Configuration Protocol DH...
Страница 37: ...DNS Provide IP addresses for the DNS server You must enter at least one IP address but you can enter up to three addresses You can also enter a list of domains to search when a DNS query is made Searc...
Страница 38: ...rogram detect an IP address However the system must be on a subnet that has a router that advertises itself by using the ICMP router discovery protocol If you are using the command line interface the...
Страница 39: ...is the default boot loader The boot loader is the first software program that runs after you power on a system From the GRUB menu you have the option of displaying the installation process to a VGA co...
Страница 40: ...to do this are described here To Connect to the Server Using the Service Processor s IP Address on page 31 If you use this method you first need to determine the service processor s IP address and the...
Страница 41: ...ssing the F2 key while the system is performing the power on self test POST c When the main BIOS screen is displayed select Advanced d When the Advanced screen is displayed select IPMI 2 0 Configurati...
Страница 42: ...on as you are prompted The screens that are displayed will vary depending on the method that you chose for assigning network information to the server DHCP or static IP address After you have entered...
Страница 43: ...orksheet on page 26 to help you enter the system and network information as you are prompted The screens that are displayed will vary depending on the method that you chose for assigning network infor...
Страница 44: ...See the Sun Fire X2250 Server Operating System Installation Guide 820 4592 for specific instructions on Solaris 10 OS installation Solaris 10 OS Training Sun provides flexible training options that a...