16
Sun Fire X2250 Server Installation Guide • May 2008
Connecting to the ILOM Service
Processor
There are two methods for connecting to the ILOM SP to perform initial setup and
configuration. Use the procedure that you prefer:
■
“To Connect to ILOM Using a Serial Connection” on page 16
■
“Connecting to ILOM Using an Ethernet Connection” on page 18
▼
To Connect to ILOM Using a Serial Connection
Use this procedure to establish a serial connection to the ILOM SP so that you can
perform initial configuration of ILOM.
Note –
This procedure assumes that you have already completed the hardware
setup and have applied standby power to your server, as described in
Chapter 1
.
1. Verify that your terminal, laptop, or terminal server is operational.
2. Configure that terminal device or the terminal emulation software running on a
laptop or PC to the following settings:
■
8N1: eight data bits, no parity, one stop bit
■
9600 baud
■
Disable hardware flow control (CTS/RTS)
■
Disable software flow control (XON/XOFF)
3. Connect a serial cable from the RJ-45 SER MGT port on the server’s back panel
to a terminal device.
See
FIGURE 1-2
for the location of this port.