Chapter 4
Maintaining the Sun Fire X2100 Server
4-39
4.5.12
CPUs
The following procedure describes how to replace a CPU. The Sun Fire X2100 Server
supports both single- and dual-CPU configurations.
Note –
The CPU is not a Customer Replaceable Unit (CRU) and should be replaced
only by trained field service technicians.
4.5.12.1
Removing a Heatsink and CPU
Follow these steps to remove a heatsink and CPU:
1. Power off the system and remove the cover as described in
Section 4.3, “Powering
Off the Server and Removing the Cover” on page 4-3
.
2. Remove the air baffle.
a. Remove the screw attaching the air baffle to the motherboard.
a. Lift the baffle straight up, just far enough to clear the guide screws on the side
of the heatsink.
b. Pull the baffle straight back to disengage it from the chassis.
FIGURE 4-30
Removing the Air Baffle
3. Unfasten the two screws securing the heatsink to the board (see
FIGURE 4-31
).