background image

28

Sun Fire 280R Server Setup and Rackmounting Guide • January 2001

Restore the Rack Enclosure

See the instructions provided with your rack enclosure to complete these steps.

1. Route and manage the AC cable and other cables within the rack enclosure.

2. Retract the enclosure’s anti-tip legs, if applicable.

3. Replace the side panels, if applicable.

4. Replace the front and back doors, if applicable.

Power On the System

You need the system key to perform this procedure.

Caution –

Never move the system when the system power is on. Movement can

cause catastrophic disk drive failure. Always power off the system before moving it.

Caution –

Before you power on the system, make sure that the cover is properly

installed.

1. Turn on power to any peripheral and external storage devices.

2. Turn on power to the monitor or terminal, if applicable.

Содержание SUN FIRE 280R

Страница 1: ...nc 901 San Antonio Road Palo Alto CA 94303 4900 U S A 650 960 1300 Send comments about this document to docfeedback sun com Sun Fire 280R Server Setup and Rackmounting Guide Part No 806 4805 10 Januar...

Страница 2: ...osystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 Etats Unis Tous droits r serv s Ce produit ou document est distribu avec des licences qui en restreignent l utilisation la copie la distributi...

Страница 3: ...Installation Options 5 Before You Begin the Installation 6 Tools Required 6 Safety Precautions 7 Assembled Slide Layout 8 Prepare the Rack Enclosure 9 Install the Slide Assemblies Into the Rack Enclo...

Страница 4: ...e January 2001 Set Up a tip Connection 23 Connect an ASCII Terminal 24 Install a Graphics Console 25 Restore the Rack Enclosure 28 Power On the System 28 Install the Operating System 31 Install Online...

Страница 5: ...d The chapters in this book are organized as follows Chapter 1 describes the boxed server and its rackmounting hardware kit contents so that you can verify what was shipped to you Chapter 2 provides s...

Страница 6: ...rder them visit the Sun Documentation Center on Fatbrain com at the public Universal Resource Locator URL http www fatbrain com documentation sun Accessing Sun Documentation Online The docs sun comSM...

Страница 7: ...e are interested in improving our documentation and welcome your comments and suggestions You can email your comments to us at docfeedback sun com Please include the part number 806 4805 10 of your do...

Страница 8: ...viii Sun Fire 280R Server Setup and Rackmounting Guide January 2001...

Страница 9: ...most internal options installed Peripherals that are not factory installed are shipped separately With the exception of internal disk drives in the Sun Fire 280R server all component part installation...

Страница 10: ...Server Setup and Rackmounting Guide January 2001 Verify the Kit Contents The shipping carton contains the following parts Sun Fire 280R server Accessory box Slide assembly box Accessory box Server Sli...

Страница 11: ...ry and slide assembly boxes contain one assembled Sun rackmounting slide kit and the following parts Note The slide assemblies innermost glides are already installed on the outside of the server enclo...

Страница 12: ...er Owner s Guide The accessory box includes a plastic bag of hardware containing screws nuts and washers that are shown below in actual size You need 8 of the 10 32 x 3 4 screws to attach the slide as...

Страница 13: ...1 Install the System Into the Rack Enclosure on page 13 The Sun Fire 280R Server Rackmounting Overview included with your documentation set illustrates the rackmounting steps in a convenient graphical...

Страница 14: ...sure requirements described in Appendix A of this guide to ensure that you meet the enclosure requirements Read the safety precautions that follow the Tools Required section For faster installation an...

Страница 15: ...ht a maximum of 75 lb 34 kg Caution The system is heavy In the following procedures two persons are required to move the system in the procedure Two persons are also required to align and install the...

Страница 16: ...280R Server Setup and Rackmounting Guide January 2001 Assembled Slide Layout Below is a view of the assembled slide assembly The rack installation is detailed in the following pages for the two slide...

Страница 17: ...stry standard rack enclosures 5 Using a felt tip marker and the Rack Buddy locate and mark the rack rail holes to use to attach each slide assembly The Rack Buddy template can help you locate the rack...

Страница 18: ...Buddy until the lower retainer opening is centered on the hole in the rail e Looking through the three middle holes on the Rack Buddy locate and mark the two rack rail holes that are most visible thr...

Страница 19: ...Install additional servers from the base up in the rack enclosure 1 If necessary adjust the back mounting bracket forward or backward on the slide assembly to accommodate the depth of the rack Use the...

Страница 20: ...e back rail of the rack count the rack rail holes to ensure that you are matching the holes used on the front rail Do not tighten the screws as far as they will go yet but tighten them so that the ass...

Страница 21: ...ward until the dimple holds the runner in the forward position in each inner rail Caution Ensure that each ball bearing slide is secured at the front of each inner slide assembly before inserting any...

Страница 22: ...h the rack with the back of the server facing the front of the rack enclosure 3 Align the crimped ends of the innermost glides on the server with the slide bracket assemblies in the rack enclosure 4 H...

Страница 23: ...the enclosure press the flat spring catch mounted on each innermost glide and slide the server all the way into the rack Tip Slide the server in and out slowly and carefully to ensure that the slide...

Страница 24: ...pletely tighten all of the slide assembly rackmounting screws a Make sure that the slide assemblies are level front to back and left to right b Tighten the eight 10 32 screws that secure the slide ass...

Страница 25: ...nstalling the System Into the Rack Enclosure 17 7 Secure the server to the rails Using the decorative panel retaining screws secure the top and bottom of the system to the rails Decorative panel Retai...

Страница 26: ...18 Sun Fire 280R Server Setup and Rackmounting Guide January 2001...

Страница 27: ...manuals for the rest of the information Complete the following tasks to finish setting up your system Connect the Power Cord on page 20 Connect the Twisted Pair Ethernet TPE Cable on page 22 Install a...

Страница 28: ...he system Connect the second AC power cord to the power inlet labeled AC 2 if necessary 3 Attach a strain relief to each AC power cord Use the strain relief to prevent accidental or inadvertent remova...

Страница 29: ...power cord to the power sequencer in the rack enclosure or to an AC outlet See the instructions provided with your rack enclosure for information about the power sequencer The outlet must connect the...

Страница 30: ...ted Pair Ethernet TPE Cable Connect the twisted pair Ethernet TPE cable to the standard Ethernet port on the back of your system 1 Connect the TPE cable to the RJ 45 connector on the server s back pan...

Страница 31: ...igure the system using one of the following procedures Establish a tip connection from another Sun system Connect an ASCII terminal to serial port A Install a graphics card monitor and keyboard on you...

Страница 32: ...ect the terminal s data cable to serial port A on the server s back panel 2 Connect the terminal s power cord to a grounded AC power outlet 3 Set the terminal to receive At 9600 baud An 8 bit signal w...

Страница 33: ...hese components are not shipped with your system See the Sun Fire 280R Server Owner s Guide for more information 1 Install the graphics card into a vacant PCI slot For the procedure see the Sun Fire 2...

Страница 34: ...26 Sun Fire 280R Server Setup and Rackmounting Guide January 2001 4 Connect the keyboard USB cable to a USB port on the back panel...

Страница 35: ...Chapter 3 Setting Up the System 27 5 Connect the mouse USB cable to a USB port on the back panel...

Страница 36: ...the side panels if applicable 4 Replace the front and back doors if applicable Power On the System You need the system key to perform this procedure Caution Never move the system when the system powe...

Страница 37: ...witch if necessary 4 Press the front panel Power button once Note The system may take anywhere from 30 seconds to two minutes before video is displayed on the graphics console or the OK prompt appears...

Страница 38: ...Locked position The Locked position prevents accidentally powering off the system and locks the front doors Note If you need to power off the system see the Sun Fire 280R Server Owner s Guide for more...

Страница 39: ...tation accompanying your Solaris software and see the Sun Fire 280R Server Owner s Guide for installation information Install Online Documentation The documentation kit contains a CD ROM compatible di...

Страница 40: ...32 Sun Fire 280R Server Setup and Rackmounting Guide January 2001...

Страница 41: ...the rackmounting hardware and the weight of any other installed devices Vertical Space Requirements Each server requires four rack units 7 inches 17 78 cm of vertical space for rack installation A 72...

Страница 42: ...crease access to the system Otherwise see the instructions provided with the rack enclosure EMI Requirements Electromagnetic interference EMI shielding requirements are met by the system chassis and m...

Отзывы: