14
Sun StorEdge N8600 Filer Storage Upgrade Guide • September 2001
3. Give the array a name. For instance, name the array “disk4.”
Note –
<
n
>
= the system-generated command count for each individual session.
4. Set the IP Address using the
set ip
command.
This enables the basic Ethernet connectivity to the arrays. For example:
5. Set the gateway address using the
set gateway
command.
This enables you to access an array outside of the subnet. For example:
6. Set the netmask using the
set netmask
command.
The netmask specifies the mask used to implement IP subnetting. For example:
This establishes connectivity for the array.
7. Reboot the MCU array by typing the following:
You can now terminate the Tip session.
8. Repeat
through
, using a different name for the MCU of each partner
group that you are configuring.
This completes the management Ethernet LAN configuration. Additional procedures
are performed through the Ethernet LAN and not the Tip terminal’s serial
connection.
:/:<
n
> set hostname disk4
disk4:/:<
n
> set ip 129.150.47.86
disk4:/:<
n
> set gateway 129.150.47.1
disk4:/:<
n
> set netmask 255.255.255.0
disk4:/:<
n
> reset
Reset the system, are you sure? [N]: Y