Sun StorEdge N8600 Filer Storage Upgrade Guide
15
Adding the Server’s IP Address
You configured the MCU of each partner group for the Ethernet management LAN
through the Tip terminal. Now, through the Ethernet management LAN, you must
configure both the MCU and the alternate MCU of each partner group that you
installed.
This is an outline of the steps in this procedure:
■
Set the password of the array.
■
Open an FTP session to the array.
■
Use FTP to bring the array’s
/etc/syslog.conf
file to your server for editing.
■
Edit the
/etc/syslog.conf
file.
■
Use FTP to return the array’s
/etc/syslog.conf
file after editing it.
▼
To Transfer the
syslog.conf
File to the Server
1. Open a Telnet session with the partner group at the IP address you just set.
2. Set the array’s root password, if you haven’t already, using the
passwd
command
(as an example:
disk7
with IP address
192.148.226.11
).
3. Enable an FTP session to the MCU array:
# telnet 192.148.226.11
disk7:/:<
n
> passwd
OLD password:
[old] password
NEW password:
[new] password
NEW password (confirm):
[new] password
disk7:/:<
n
> exit
#
# ftp 192.148.226.11
Connected to 192.148.226.11.
220 server-name FTP server (SunOS 5.8) ready.
disk7(192.148.226.11:root):