background image

Please

Recycle

Copyright 2001 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303-4900 U.S.A. All rights reserved.

This product or document is distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or
document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party
software, including font technology, is copyrighted and licensed from Sun suppliers.

Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in
the U.S. and other countries, exclusively licensed through X/Open Company, Ltd.

Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, Solaris, Sun StorEdge, and Sun Enterprise are trademarks, registered
trademarks, or service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are
trademarks or registered trademarks of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are
based upon an architecture developed by Sun Microsystems, Inc. The Energy Star logo is a registered trademark of EPA.

The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges
the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun
holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN
LOOK GUIs and otherwise comply with Sun’s written license agreements.

Federal Acquisitions: Commercial Software—Government Users Subject to Standard License Terms and Conditions.

DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.

Copyright 2001 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303-4900 Etats-Unis. Tous droits réservés.

Ce produit ou document est distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la décompilation. Aucune
partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l’autorisation préalable et
écrite de Sun et de ses bailleurs de licence, s’il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de
caractères, est protégé par un copyright et licencié par des fournisseurs de Sun.

Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque
déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.

Sun, Sun Microsystems, le logo Sun, AnswerBook2, docs.sun.com, Solaris, Sun StorEdge, et Sun Enterprise sont des marques de fabrique ou des
marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays. Toutes les marques SPARC sont
utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d’autres
pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc.

L’interface d’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun
reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d’utilisation visuelle ou graphique
pour l’industrie de l’informatique. Sun détient une licence non exclusive de Xerox sur l’interface d’utilisation graphique Xerox, cette licence
couvrant également les licenciés de Sun qui mettent en place l’interface d’utilisation graphique OPEN LOOK et qui en outre se conforment aux
licences écrites de Sun.

LA DOCUMENTATION EST FOURNIE “EN L’ETAT” ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT
TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A
L’ABSENCE DE CONTREFAÇON.

Содержание StorEdge N8600 Filer

Страница 1: ...Inc 901 San Antonio Road Palo Alto CA 94303 4900 U S A 650 960 1300 Send comments about this document to docfeedback sun com Sun StorEdge N8600 Filer Storage Upgrade Guide Part No 816 1912 10 September 2001 Revision 01 ...

Страница 2: ...Copyright 2001 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 Etats Unis Tous droits réservés Ce produit ou document est distribué avec des licences qui en restreignent l utilisation la copie la distribution et la décompilation Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation préalable et écrite d...

Страница 3: ...he Expansion Cabinet 5 To Install the Expansion Cabinet 5 To Install the FC 100 Hubs 5 Installing a Sun StorEdge T3 Array Partner Group 6 Installing the Rackmount Kit 6 To Install the Rackmount Kit 6 Installing the Arrays 7 To Install the Arrays 7 Connecting the Arrays 8 To Interconnect the New Partner Group 8 To Connect the Data Network Fiber Optic Cable 9 To Connect the Management LAN Ethernet C...

Страница 4: ... the Partner Group 13 Adding the Partner Group s IP Settings 13 To Add the IP Settings 13 Adding the Server s IP Address 15 To Transfer the syslog conf File to the Server 15 To Edit the etc syslog conf File 17 To Transfer the syslog conf File Back to the Array 17 Finishing and Verifying the Installation 19 To Create Logical Volumes 19 To Verify the Installation 19 ...

Страница 5: ...l not be able to create shares with the GUI See Finishing and Verifying the Installation on page 19 for more information The filer incorporates an internal Ethernet local area network LAN that only connects the server with the Sun StorEdge T3 arrays contained within the filer This internal network is secure and cannot be directly accessed from outside the filer The filer can be attached to another...

Страница 6: ...Sun Microsystems Inc For a list of documents and how to order them visit the Sun Documentation Center on Fatbrain com at http www fatbrain com documentation sun Document TItle Part Number Sun StorEdge T3 Array Cabinet Installation Guide 806 7979 Sun StorEdge T3 Array Administrator s Guide 806 1063 Sun StorEdge T3 Array Release Notes 806 1497 Sun Enterprise 6500 5500 4500 Systems Reference Manual 8...

Страница 7: ...es Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can email your comments to Sun at docfeedback sun com Please include the part number 8xx xxxx xx of your document in the subject line of your email ...

Страница 8: ...which contains two FC AL host bus adapters which connect to the partner group s FC AL hubs The failure of any host bus adapter or I O module poses no threat to availability because the FC AL hubs are connected in such a way that no rack is connected to only one I O module See FIGURE 3 for one possible wiring scheme The only requirement to maintain redundancy at the I O modules is to have each of t...

Страница 9: ... StorEdge Expansion Cabinet Installation and Service Manual to install the expansion cabinet Note The expansion cabinet has two stabilizer legs that must be installed to maintain the cabinet s stability during the installation of the arrays which are heavy Be sure to install these stabilizer legs and be sure to use them as instructed To Install the FC 100 Hubs Follow the instructions in the Rackmo...

Страница 10: ...his procedure for each partner group that you are adding to the Sun StorEdge N8600 Filer Caution A single Sun StorEdge T3 array with its support plate can weigh over 85 pounds 187 kilograms Never try to install it by yourself Be sure to extend the stabilizer legs of the expansion cabinet have another person assist you and follow all instructions carefully Follow the instructions in the Sun StorEdg...

Страница 11: ...he cabling configuration makes one of them the MCU and the other the alternate MCU By convention the lower of the two is called the MCU and the cabling diagrams in this procedure will make it so You can install either one on top but the cabling procedures will make the bottom one the MCU Note There is no need to power off the filer in order to install additional partner groups Perform this procedu...

Страница 12: ...rtner group that you are adding to the Sun StorEdge N8600 Filer Use the interconnect cables to interconnect the array partner group as shown in FIGURE 1 This wiring configuration causes the lower array to become the MCU and the upper array to become the alternate MCU FIGURE 1 Connecting the Interconnect Cables Alternate MCU array MCU array Interconnect cards ...

Страница 13: ... of the fiber optic cable to the next available port of the MCU FC AL hub as shown in FIGURE 3 3 Connect a fiber optic cable to the alternate MCU array of a partner group Use a Media Interface Adapter MIA to connect the fiber optic cable as shown in FIGURE 2 4 Connect the other end of the fiber optic cable to the next available port of the alternate MCU FC AL hub as shown in FIGURE 3 10BASE T Ethe...

Страница 14: ... Upgrade Guide September 2001 FIGURE 3 Data Network Interconnect for Sun StorEdge N8600 Filer Rack 1 Rack 2 Rack 3 MCU FC AL hub Alternate MCU FC AL hub I O module 1 I O module 2 I O module 3 Sun Enterprise E4500 server Alternate MCU MCU ...

Страница 15: ...nly if you are adding an expansion rack 1 Connect a standard 10 100BASE T Ethernet cable to port 12 of the Ethernet hub of the expansion rack that you are adding 2 Connect the other end of the Ethernet cable to any available port on the hub of the next expansion rack in line toward the rack that contains the server See FIGURE 4 3 Set the MDI MDIX switch of the Ethernet hub of the added expansion r...

Страница 16: ... 4 Management Network Interconnect for Sun StorEdge N8600 Filer Powering On the Arrays Power up the arrays by pressing the two power switches on the back of each array Wait powering on takes several minutes Management LAN 10 100BASE T Ethernet Company wide LAN gigabit Ethernet Company wide LAN 10 100BASE T Ethernet MDI MDIX switch Ethernet hub Sun Enterprise 4500 server ...

Страница 17: ...ocedure for the MCU of each partner group installed but not for its alternate MCU To Add the IP Settings The partner groups are connected to a local area network LAN as shown in FIGURE 4 To set up the connectivity for a partner group perform the following steps 1 Connect a terminal to the COM Port see FIGURE 2 on the back of the MCU array A Tip kit was supplied with your Sun StorEdge N8600 filer t...

Страница 18: ... set netmask command The netmask specifies the mask used to implement IP subnetting For example This establishes connectivity for the array 7 Reboot the MCU array by typing the following You can now terminate the Tip session 8 Repeat Step 1 through Step 7 using a different name for the MCU of each partner group that you are configuring This completes the management Ethernet LAN configuration Addit...

Страница 19: ...file to your server for editing Edit the etc syslog conf file Use FTP to return the array s etc syslog conf file after editing it To Transfer the syslog conf File to the Server 1 Open a Telnet session with the partner group at the IP address you just set 2 Set the array s root password if you haven t already using the passwd command as an example disk7 with IP address 192 148 226 11 3 Enable an FT...

Страница 20: ...ectory on the array to your working directory using the get command 9 Exit the FTP session using the bye command disk7 192 148 226 11 root root 331 Password required for root Password password 230 User root logged in ftp ftp cd etc 250 CWD command successful ftp ftp lcd tmp Local directory now tmp ftp ftp get syslog conf 200 PORT command successful 150 ASCII data connection for syslog conf 192 148...

Страница 21: ...o separate field entries when editing the syslog conf file If tabs are not used any edits will not be recognized by the array 3 Save the syslog conf file and exit the editor This change enables the array to send Info Notice Warning and Error messages to the server To Transfer the syslog conf File Back to the Array 1 Start an FTP session from the server to the array For example 2 Log on to the arra...

Страница 22: ...cess the array by either a Telnet session or a serial connection 9 Reboot the array by typing the following 10 Repeat Adding the Server s IP Address on page 15 for each MCU and for each alternate MCU array of all partner groups that you installed ftp cd etc 250 CWD command successful ftp ftp lcd tmp Local directory now tmp ftp ftp put syslog conf 200 PORT command successful 150 ASCII data connecti...

Страница 23: ...ray Administrator s Guide 806 1063 To Verify the Installation 1 Start the Filer Administration Tool Refer to To Start the Filer Administration Tool in the Sun StorEdge N8400 and N8600 Filer Administrator s Guide 2 Create a new share Refer to To Add a New Share in the Sun StorEdge N8400 and N8600 Filer Administrator s Guide 3 Mount the newly created share from another host using both the NFS and CI...

Страница 24: ...20 Sun StorEdge N8600 Filer Storage Upgrade Guide September 2001 ...

Отзывы: