Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000
FIGURE 3-25
Connecting the LED Cable to the Main Logic Board
3.8.4
Reassembling the MultiPack-FC
1. Install the drive cage and the main logic board assembly.
Push the assembly all the way back into the chassis so that it meets the chassis I/O
connectors area.
2. Tighten the drive cage and the main logic board assembly screws in this order:
■
Two screws by the drive cage
■
Two screws by the I/O connectors
■
Two screws on the bottom of the chassis
3. Install the daughter board into the main logic board (FIGURE 3-26).
4. Install the daughter board clip onto the daughter board. Tighten the screws on the
clip to the drive cage (FIGURE 3-26).
Blue strand
J0902
Содержание StorEdge MultiPack-FC
Страница 5: ...Regulatory Compliance Statements v...
Страница 6: ...vi Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 14: ...xiv Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 16: ...xvi Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 20: ...xx Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 24: ...xxiv Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 34: ...1 10 Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 50: ...2 16 Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 55: ...Chapter 3 Service 3 5 FIGURE 3 3 Removing the Power Supply FIGURE 3 4 Drive Cage With Backplane...
Страница 61: ...Chapter 3 Service 3 11 FIGURE 3 9 Opening the Drive Bracket FIGURE 3 10 Removing a Drive...
Страница 71: ...Chapter 3 Service 3 21 FIGURE 3 19 Drive Cage and Chassis Bottom Screws...
Страница 80: ...3 30 Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...