Chapter 3
Service
3-9
2. Use the
luxadm remove_device
command to remove the disk from the Fibre
Channel Arbitrated Loop (FC-AL).
This command is interactive and will prompt you to physically remove the drive.
For example:
Note –
Do not press Return until Step 3 and Step 4 have been completed.
Note –
If the
luxadm remove_device
command fails to remove the drive, use of
the
luxadm remove_device -F
option may be required. Be sure you have
stopped all input/output to the drive before using the
-F
option. Refer to the
luxadm
Man Page for more information.
3. Open the drive access panel (FIGURE 3-8).
# luxadm remove_device /dev/rdsk/c3t8d0s2
WARNING!!! Please ensure that no filesystems are mounted on these
device(s).
All data on these devices should have been backed up.
The list of devices which will be removed is:
1: Device /dev/rdsk/c3t8d0s2
Please enter ‘q’ to Quit or <Return> to Continue:
stopping: /dev/rdsk/c3t8d0s0....Done
offlining: /dev/rdsk/c3t8d0s0....Done
Hit <Return> after removing the device(s).
Содержание StorEdge MultiPack-FC
Страница 5: ...Regulatory Compliance Statements v...
Страница 6: ...vi Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 14: ...xiv Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 16: ...xvi Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 20: ...xx Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 24: ...xxiv Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 34: ...1 10 Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 50: ...2 16 Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...
Страница 55: ...Chapter 3 Service 3 5 FIGURE 3 3 Removing the Power Supply FIGURE 3 4 Drive Cage With Backplane...
Страница 61: ...Chapter 3 Service 3 11 FIGURE 3 9 Opening the Drive Bracket FIGURE 3 10 Removing a Drive...
Страница 71: ...Chapter 3 Service 3 21 FIGURE 3 19 Drive Cage and Chassis Bottom Screws...
Страница 80: ...3 30 Sun StorEdge MultiPack FC Installation Operation and Service Manual August 2000...