Operational Requirements
The operational requirements for the Universal Storage Platform VM include:
■
LAN connection (or RJ-11 analog phone line) for Hi-Track
®
The Hi-Track maintenance support tool monitors the operation of the Universal Storage
Platform VM, collects hardware status and error data, and transmits this data via LAN (or
modem) to the Hitachi Data Systems Support Center. In the event of a component failure,
Hi-Track reports the failure to the Support Center, with no action required on the part of the user.
Hi-Track enables most problems to be identified and fixed prior to actual failure, and the
advanced redundancy features enable the storage system to remain operational even if one or
more components fail.
■
LAN for Storage Navigator
Hitachi Storage Navigator communicates directly with the Universal Storage Platform VM via
LAN to obtain system configuration and status information and send user-requested commands
to the storage system. Storage Navigator serves as the integrated interface for all Resource
Manager components.
■
Cable length for front-end directors
Table 2-11 lists the cable length requirements for the front-end directors (FEDs) in the Universal
Storage Platform VM.
■
External storage
If you plan to attach external storage to the Universal Storage Platform VM, be sure to include
the appropriate power and space requirements in your planning.
Table 2- 11
FED Cable Length Requirements
Cable
Maximum Cable Length (Data Transfer Rate)
ESCON
3 km
FICON Short Wave
50/125µm multimode
62.5/125µm multimode
500 m (100 MB/s), 300 m (200 MB/s), 150 m (400 MB/s)
300 m (100 MB/s), 150 m (200 MB/s), 75 m (400 MB/s)
FICON Long Wave
10 km
Fibre Channel Short Wave
50/125µm multimode
62.5/125µm multimode
500 m (100 MB/s), 300 m (200 MB/s), 150 m (400 MB/s)
300 m (100 MB/s), 150 m (200 MB/s), 75 m (400 MB/s)
Fibre Channel Long Wave
10 km
Units and Unit Conversions
Just the Facts
October 2007
172
Sun Confidential – For Internal Use and Authorized Partner Use Only
Содержание StorageTek 9985V
Страница 174: ...Just the Facts October 2007 174 Sun Confidential For Internal Use and Authorized Partner Use Only ...
Страница 175: ...I Just the Facts October 2007 175 Sun Confidential For Internal Use and Authorized Partner Use Only ...
Страница 176: ...Just the Facts October 2007 176 Sun Confidential For Internal Use and Authorized Partner Use Only ...