Sun Fire V210 and V240 Servers Administration Guide • April 2003
prtconf
The
prtconf
command displays the Solaris device tree. This tree includes all the
devices probed by OpenBoot firmware, as well as additional devices, like individual
disks, that only the operating environment software “knows” about. The output of
prtconf
also includes the total amount of system memory.
CODE EXAMPLE 6-6
shows
an excerpt of
prtconf
output (truncated to save space).
CODE EXAMPLE 6-6
prtconf
Command Output (truncated)
The
prtconf
command’s
-p
option produces output similar to the OpenBoot
show-devs
command. This output lists only those devices compiled by the system
firmware.
# prtconf
System Configuration: Sun Microsystems sun4u
Memory size: 1024 Megabytes
System Peripherals (Software Nodes):
SUNW,Sun-Fire-V240
packages (driver not attached)
SUNW,builtin-drivers (driver not attached)
deblocker (driver not attached)
disk-label (driver not attached)
terminal-emulator (driver not attached)
dropins (driver not attached)
kbd-translator (driver not attached)
obp-tftp (driver not attached)
SUNW,i2c-ram-device (driver not attached)
SUNW,fru-device (driver not attached)
ufs-file-system (driver not attached)
chosen (driver not attached)
openprom (driver not attached)
client-services (driver not attached)
options, instance #0
aliases (driver not attached)
memory (driver not attached)
virtual-memory (driver not attached)
SUNW,UltraSPARC-IIIi (driver not attached)
memory-controller, instance #0
SUNW,UltraSPARC-IIIi (driver not attached)
memory-controller, instance #1 ...
Содержание Fire V240
Страница 8: ...Figures viii FIGURE 6 5 watch net all Diagnostic Output Message 80 80...
Страница 34: ...20 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Страница 50: ...36 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Страница 60: ...46 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Страница 66: ...52 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Страница 102: ...88 Sun Fire V210 and V240 Servers Administration Guide April 2003...