Chapter 1
Introduction
17
Power Supply Unit (PSU)
The Sun Fire V210 server has one PSU and two associated status indicators. A
summary of the function of the indicators is given in
TABLE 1-10
.
The Sun Fire V240 server has dual redundant PSUs. This server has an additional
LED indicator which tells you when a power supply unit is ready to be removed
with the server running. (The Sun Fire V210 server has a single PSU and does not
support this function.)
A summary of the function of this indicator is given in
TABLE 1-11
.
Caution –
As long as an AC power cord remains connected to the server,
potentially dangerous voltages could be present within the server.
TABLE 1-10
Power Supply Unit Indicators
LED Colour
LED State
Component Status
Green
On
Power is present and PSU is active.
Off
Either power is not present, or the PSU has shut down
due to an internal protection event.
Amber
On
The PSU has shut down due to an internal protection
event and requires service attention.
Off
The PSU is operating normally.
TABLE 1-11
Power Supply Unit Ready To Remove Indicator (Sun Fire V240 only)
LED Colour
LED State
Component Status
Blue
On
PSU is ready to be removed.
Off
The PSU is not ready for removal.
Содержание Fire V240
Страница 8: ...Figures viii FIGURE 6 5 watch net all Diagnostic Output Message 80 80...
Страница 34: ...20 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Страница 50: ...36 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Страница 60: ...46 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Страница 66: ...52 Sun Fire V210 and V240 Servers Administration Guide April 2003...
Страница 102: ...88 Sun Fire V210 and V240 Servers Administration Guide April 2003...