8
Sun Enterprise Tape Library 7/3500 Field Service Manual • July 1997
Actuator Driver PWA (A2)
The actuator driver PWA drives the library robotic mechanisms by using low-level
signal commands. This PWA provides the following functions:
■
Shunt over-voltage protection (OVP) regulator
■
X-axis motor interface
■
Y-axis motor interface
■
Extension motor interface
■
Tape drive handle motor interface
■
Load port lockout solenoid interface
Shunt OVP
The shunt OVP regulator on the actuator driver board serves two functions:
■
Over-voltage protection of the motor power supply
■
Rapid discharge of +48 VDC and +24 VDC in the event of a fault condition
The OVP regulator “shunts” to ground any regenerated current that create a voltage
fluctuation above 51.5 VDC. Therefore, the +48 VDC supply line is regulated to
below +51.5 VDC. A fault condition results in the rapid discharge of the motor bus.
For example, a fault condition occurs when the door is opened, the STOP switch is
pressed, the microprocessor watchdog times out, or when the +5V or +12V is out of
regulation. A fault condition immediately shuts down all actuators and rapidly
discharges the motor bus voltages within 100 milliseconds.
X-Axis Motor Interface
The x-axis motor interface on the actuator driver PWA receives open-loop low-level
step, direction, and current commands from the robotics controller. This PWA
amplifies and synthesizes the command signal to provide a high current two-phase
microstepping drive signal to the x-axis stepper motor.
Y-Axis Motor Interface
The y-axis motor interface on the actuator driver PWA receives open-loop low-level
step, direction, and current commands from the robotics controller. The PWA
amplifies and synthesizes the command signal to provide a high current two-phase
microstepping drive signal to the y-axis stepper motor.
Содержание Enterprise Tape Library 7/3500
Страница 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Страница 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Страница 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Страница 52: ...22 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 FIGURE 1 11 Fan Locations TJ00016a ...
Страница 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Страница 116: ...86 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 FIGURE 3 3 Tape Drive Interface PWA TA00109b ...
Страница 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Страница 167: ...Chapter 4 FRU Removal and Replacement 137 FIGURE 4 20 Tape Drive Distribution PWA Tape drive distribution PWA TJ00081A ...
Страница 177: ...Chapter 4 FRU Removal and Replacement 147 FIGURE 4 24 Robotics Controller PWA TJ00036a Robotics controller PWA ...
Страница 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Страница 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Страница 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Страница 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...