plate to casing gasket (351A). Lubricate gasket to hold it in place.
21. Slide suction side plate into place aligning the four (4) studs (356E) with the holes in
the casing. “O” ring lubricant or ant seize lubricant may be used to assist installation.
Tighten side plate nuts (357A).
22. Slide reassembled power unit into casing. Tighten adapter to casing bolts (370)
evenly to be sure stuffing box cover pulls into casing evenly. Check with feeler
gauge points at 90º apart to assure even spacing around adapter.
23. Install pedestal to bearing frame bolts (529). Install shims as needed and tighten
bolts.
24. Adjust the impeller clearance according to the instructions in Appendix A.
25. If the pump is a packed box, refer to
3. Installation, Stuffing Box
26. If the pump has a mechanical seal, refer to
3. Installation, Stuffing Box
on page 7.