5 OPERATION
5.1 LUBRICATION
Pumps are shipped from the manufacture
WITHOUT
oil. Oil must be installed before
operation
Ball bearings are very sensitive to both over and under lubrication, both being
detrimental to bearing performance. Either case is detrimental to bearing performance.
Use a thermometer to determine overheating. Excessive overheating will reduce
bearing life.
The relationship between temperature and pumpage temperature is an indication of
performance.
Table 2
indicates the relationship between these temperatures.
Table 2
Degrees Fahrenheit
Pumping liquid temperature
60
°
200
°
300
°
Approximate normal line bearing temperature
115
°
140
°
160
°
The information shown in
Table 2
is based on a room temperature of 70
°
F. Maximum
bearing temperature is 175
°
F. The temperatures shown above have a tolerance of plus
15
°
F. It is necessary to flush water on the shaft for liquid temperatures above 250
°
F.
This can be done either through a flushing gland or the stuffing box seal cage.
5.1.1 Oil Lubrication
Use only high quality turbine oil with rust and oxidation inhibitors. Service temperatures
determine oil viscosity. See
Table 3
.
Use a 300 SSU viscosity at 100
°
F for applications where pumping temperatures are
below 200
°
F. At pumping temperatures above 350
°
F, use 470 SSU at 100
°
F with
optional cooler.
Table 3
Bearing Temperature
ISO Grade
Viscosity at 100 Degrees F
Up to 150
°
F
46
215 SSU
150
°
F to 200
°
F
68
300 SSU
Above 200
°
F
100
470 SSU
Содержание 2175 L
Страница 1: ......
Страница 2: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ii SUMMIT PUMP MODEL 2175...
Страница 6: ......
Страница 40: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL 34 SUMMIT PUMP MODEL 2175 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 41: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL SUMMIT PUMP MODEL 2175 35 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 42: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL 36 SUMMIT PUMP MODEL 2175 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 44: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL SUMMIT PUMP MODEL 2175...