SummaSign Pro T-series Cutters
User’ s Manual
Operation
2-18
2.4.17. FLEX-CUT
FLEX-CUT can be set to OFF, to Mode 1 or Mode 2. When the cutter is set to
mode 1 or mode 2, it will alternately cut one length with full pressure, and one
length with reduced pressure. The feature FLEX-CUT offers the advantage that it
cuts completely through the material, yet allowing the material to stay
together by means of the small media bridges.
MODE 1 is the quickest mode, but it is less precise because the pressure
changes during the cutting. MODE 2 is a lot slower, but at the same time it is
much more precise, as the cutter stops at every change of pressure. Pressing
the
1
key will activate the configuration menu, which allows you to set the
cutting pressure and the cut length.
1.
CUT LENGTH
This parameter determines the length that is cut with full pressure. By pressing
the
1
key, the FLEX-CUT test pattern will be cut.
2.
FLEX-CUT LENGTH
This parameter determines the length that will be cut with reduced pressure or
without pressure. By pressing the
1
key, the FLEX-CUT pattern will be cut.
3.
FLEX PRESSURE
This parameter determines the pressure of the FLEX-CUT LENGTH. By pressing the
1
key, the FLEX-CUT test pattern is cut.
2.4.18. RECUT OFFSET
The recut offset submenu is used to set or modify the distances between the
drawings when making multiple recuts.
The default recut offset value is 0 mm.
The distance can be set between o and 255 mm.
On the LCD, the active recut offset value is marked with an *.