background image

31 

 

Cleaning

 

To keep excellent splice quality, regular cleaning and inspection are required. 
Especially cleaning should be performed before and after each use. We recommend 
your splicer to be checked through our maintenance service once a year.

 

Turn off the TYPE-66 before maintenance work. Failure to do so 
may cause electric shock.

 

Clean each part with a cotton swab. Please bear in mind that daily cleaning can 
maintain splicer performance. Clean components before and after use.

 

Names of components 

3. Maintenance

 

Mirror 

Bare fiber pad 

Mirror 
protection 
glass 

Warning 

V-groove 

LED 

Electrode for 
high voltage side

LED 

Electrode 

cover plate 

thumb-screw 

& electrode 

cover plate 

Electrode for 

Objective lens 

(below electrode) 

Objective lens 

(below electrode)

Electrode cover   
plate thumb-screw & 
electrode cover plate

low voltage side

Содержание TYPE-66M12

Страница 1: ...OME0724004H Mass Fusion Splicer TYPE 66M12 Guide to operation Sumitomo Type 66M12 Specs Provided by www AAATesters com...

Страница 2: ...bol indicates actions that are prohibited This symbol indicates actions that must be taken The meaning of Warning and Caution This symbol indicates explanations about extremely dangerous matters If us...

Страница 3: ...ys use the connection method as defined in this manual Failure to do so may cause a fire or electric shock 11 Only use a voltage within the indicated power voltage Failure to do so may cause a fire or...

Страница 4: ...store the battery together with any personal jewelry hairpins or other Metallic objects Doing so can cause an electrical short circuit Also excessive current flow may cause abnormal chemical reaction...

Страница 5: ...airpins or other metallic objects Doing so can cause an electrical short circuit Also excessive current flow may cause abnormal chemical reaction in battery heat generation bursting and fire 3 Do not...

Страница 6: ...European Union member states The crossed out wheelie bin symbol found on our products indicates that it should not be disposed of together with household waste To prevent possible harm to human healt...

Страница 7: ...r or disclose the whole or part of the writings to the public or unidentified parties and transfer disclose or display the electrical format of the writings through online media 2 make copy of the wri...

Страница 8: ...Notification of North American patents on the TYPE 66 U S Patents 4 812 010 5 777 867 6 287 020 6 437 299 6 518 551 6 519 405 CANADA Patents 2 183 840 2 321 400...

Страница 9: ...tery charging 13 DC operation car battery 14 Battery refreshing 14 Precautions for battery module 14 Operating procedures 16 Turning on the TYPE 66 16 Initial screen 17 Fiber type and protection sleev...

Страница 10: ...intenance settings 45 5 Other convenient functions 46 Back monitor type 46 Dual heat shrink oven 46 Detachable attachable bare fiber pads 47 Auto start 47 Splice data storage function 48 Tripod fixing...

Страница 11: ...25 m Fiber count 1 2 4 5 6 8 10 12 Cleave length 10mm The TYPE 66 key features are Dual heat shrink oven For more information see page 46 2 heat shrink ovens are equipped with the fusion splicer The o...

Страница 12: ...ooling tray 1 pc 7 Spare electrodes ER 10 1 pair 8 Operation manual 1 OME0724004 1 pc 9 Quick reference guide 1 OME0724004 2 1 pc 10 Carrying case CC 66 1 pc The above package is an example The packag...

Страница 13: ...d up to 12 fiber ribbon Jacket remover JR M03 Applicable fiber Single fiber Applicable coating diameter 250 m 900 m Hot Jacket remover JR 6 Applicable fiber single fiber and up to 12 fiber ribbon Repl...

Страница 14: ...me and usage and are replaceable by a customer Therefore they will not be covered under warranty Monitor Monitors are considered a component that degrades and is deteriorated with time and usage Sumit...

Страница 15: ...o heat and shrink fiber protection sleeves 2 heat shrink ovens front and rear are equipped Power module bay Power supply or battery module is installed Input output panel DC output terminal for hot ja...

Страница 16: ...page and display key guidance Power key LED Used to turn on and off the splicer LED illuminates while the splicer is on SET key Starts a splicing operation RESET key Used to cancel a splicing operatio...

Страница 17: ...mirrors from any dust or dirt Fiber holder stage A fiber holder is placed on the stage 2 3 Fiber guide A small green light is illuminated for easy fiber placement 4 Electrodes Arc is generated between...

Страница 18: ...tion sleeve 2 Heat shrink oven clamps Hold fiber straight Input output panel 3 1 2 Video output terminal Used for an external monitor 3 DC output terminal Used to supply DC power to a hot jacket remov...

Страница 19: ...ce with the fusion splicer For further information on each step please see the page described below Turning on the TYPE 66 Page 16 Initial screen Page 17 Starting the automatic splice Page 25 9 Mainte...

Страница 20: ...y module PS 66 into the module bay Installation Insert the power supply module PS 66 into the module bay and slide forward until it locks into space Removal 1 While pressing the release button located...

Страница 21: ...Using an unused battery module 1 splice cycle shall be completed in 90 seconds in room temperature without using a heated jacket remover If the power is turned on after the battery module is installe...

Страница 22: ...button The LED will light up for a few seconds to indicate the battery status in one of four levels Indicator Battery level The battery level is also displayed by the battery level indicator on the m...

Страница 23: ...ule can be charged while installed in the splicer but the power cannot be turned on When charging is complete remove the battery module from the splicer and re install it 3 Charge the battery module w...

Страница 24: ...y turned off Connect the PS 66 power supply module to the BU 66 battery module for charging Battery Refresh PAGE MOVE SELECT Refresh time depends on the amount of charge remaining in the battery modul...

Страница 25: ...ng to use the battery module for a long period charge the battery module once every 6 months To extend battery life refresh the battery module once a month When should the battery be replaced If you a...

Страница 26: ...on monitors The monitor viewing angle can be adjusted Power cord 1 Prepare the power supply referring to page10 15 2 Adjust the monitor for optimum viewing angles 3 Press the power key for more than...

Страница 27: ...MITOMO ELECTRIC INDUSTRIES LTD Initialize is complete Ready screen Ready SM 12c 40mm 12c Y Press the POWER key for more than 1 second until the TEMP BATT indicator LEDs illuminate 2 Place an optical f...

Страница 28: ...he convex portion of the fiber holder 6 The fiber coating is removed Take out the fiber holder from the JR 6 9 Repeat the stripping and cleaning processes for the other fiber 8 Lightly brush the ends...

Страница 29: ...g clamp lid and the top clamp lever The blade carriage should be in the forward position Blade carriage 1 2 2 1 Place the fiber holder in the FC 6M Touch the edge of the fiber holder against the FC 6M...

Страница 30: ...ends insert each fiber immediately after preparation 3 Glass fiber fragments are extremely sharp Handle with care 4 2 Lift the fiber holder 4 3 Lift the off cut and dispose of it properly Be careful n...

Страница 31: ...ing the pin of the fiber holder stage into the hole of the fiber holder Do not touch the fiber end face against any surface Inserting fibers into the splicer 0 Open the hood 3 Ensure that the fibers a...

Страница 32: ...t 1 Strip the coatings clean cleave and insert the fibers Hereinafter called prepare the fiber After initialization check to see if the displayed fiber type and protection sleeve type are correct if n...

Страница 33: ...er again and repeat the test until ARC OK is displayed Press the FIBER key The arc test result with fiber images will be displayed Arc Test Ready SM 12c 40mm 12c Y Arc SM 12c 40mm 12c Y Arc OK FIBER L...

Страница 34: ...arc test Prepare the fiber again Start splicing Fiber preparation 1 Be sure to slip the fiber protection sleeve over one of the fibers to be spliced before stripping and cleaving the fibers The fiber...

Страница 35: ...ck 0000 Y Y X Arc Count is displayed on the screen Y X Open Hood Ave 0 01dB 3 5 1 2 4 6 7 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 9 8 11 10 12 Open Hood is displayed Proof test is...

Страница 36: ...8 10 PAGE MEMO BACK Offset CutL CutR Gap 1 2 2 0 1 0 5 0 2 35 1 Irregular R 010 L 013 3 0 7 0 6 0 5 35 6 4 0 3 0 8 0 7 39 6 9 0 9 0 7 0 5 35 1 10 0 1 0 5 0 3 35 1 11 0 6 0 7 0 2 36 9 12 0 8 0 3 0 4 3...

Страница 37: ...spliced fiber to be broken resulting in loss of the long term reliability of the fiber Y X Ave 0 01dB Estimation Loss 3 5 1 2 4 6 7 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 9 8 11...

Страница 38: ...6 7 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 0 01 9 8 11 10 0 01 12 Evaluating splice quality If the spliced fiber is as follows or estimated losses are high re do the entire splice White line Bul...

Страница 39: ...open together 1 Open the hood and the lid of the one fiber holder Slide the protection sleeve to the center of the splice Rear Front Rear Front 4 Press the HEAT key to start the shrinking process The...

Страница 40: ...t Handle with care Never touch the surface of the heating plate during the heating operation Doing so may cause personal injury and damage to the heat shrink oven Caution Evaluating protection sleeve...

Страница 41: ...ause electric shock Clean each part with a cotton swab Please bear in mind that daily cleaning can maintain splicer performance Clean components before and after use Names of components 3 Maintenance...

Страница 42: ...clean them with a cotton swab moistened with alcohol Do not use a canned air for cleaning Chemical reaction may deteriorate the 32 lens resulting in a loss of splicing capability 1 Prepare a cotton s...

Страница 43: ...ly too much force when cleaning Cleaning microscopes objective lenses If an unclear fiber image is still displayed or LED error occurs again after cleaning LEDs or a mirror protection glass clean the...

Страница 44: ...n accumulate in the heat shrink oven easily Clean the heating plate regularly with a dry cotton swab Clean the heating plate with a dry cotton swab Caution Remove moisture or alcohol on the heat shrin...

Страница 45: ...bscrews 3 Lift the electrode cover plate as shown in the left figure 4 Remove the old electrode 5 Install a new electrode When handling the electrodes avoid touching the electrode tips with anything C...

Страница 46: ...ble arcing performance Caution Replacing monitor protection panel The damaged or contaminated monitor protection panel can be replaced 1 Unscrew the 4 screws to remove the monitor protection panel 2 F...

Страница 47: ...ansport the machine in its case Observe the following instructions Clean the TYPE 66 and all accessories before storing them Be sure to remove the battery from the TYPE 66 and store it in a given plac...

Страница 48: ...with care Caution Close the carrying case completely and latch it before transportation Pay attention to storage temperature and dew condensation when storing the splicer The battery module is self d...

Страница 49: ...the details of heater conditions refer to page 40 If you would like to change heater condition parameters refer to page 42 In this screen monitor brightness can be adjusted if the Brightness control k...

Страница 50: ...U T G 651 DSM 1c Can be used for splicing dispersion shifted single fiber ITU T G 653 Can be used for splicing dispersion shifted 2 fiber ribbon ITU T G 653 DSM 2c Can be used for splicing dispersion...

Страница 51: ...40 dot BACK MOVE SELECT PAGE OFF Heating Duration A 22 sec 230 C Heat up Temp B 200 C Heating Duration B 05 sec Finish Temp 150 C BACK MOVE SELECT PAGE Press the key to display key Fusion Time 3 3 Pre...

Страница 52: ...perature it maintains the temperature of both ends for this duration Finish Temp This is the finish temperature to take out the sleeve The flashing indication on the keypad stops at this temperature a...

Страница 53: ...ight for v groove ON Date dd mm yy hh mm 12 02 07 17 00 PAGE 1 Use the MOVE keys to select the function you would like to change 2 Use the SELECT key to change the settings 3 Press the PAGE key to go...

Страница 54: ...function switches the temperature units Heater Auto Start This function starts the heating process when the fiber is placed into the heat shrink oven Light for V groove This function sets the V groove...

Страница 55: ...BACK 1 2 Conditioning Arc Reset Arc Count Maintenance when electrodes changed Maintenance 2 2 Restore Data Self Inspection Battery Refresh MOVE SELECT PAGE BACK Ready SM 12c 40mm 12c Y Maintenance Pag...

Страница 56: ...See also page 43 44 Back 46 Dual heat shrink oven 2 heat shrink ovens are equipped with the TYPE 66 The ovens run individually and splicing operation can be improved more effectively Both ovens also...

Страница 57: ...ned the bare fiber pad is removed from the hood 3 You can check if the fiber is placed seated in the V groove properly by the pad 4 When the hood is closed the hood catches the bare fiber pad The hood...

Страница 58: ...would like to view Description of data Offset Inspected offset of diameter axis CutL Inspected cleave angle of left fiber CutR Inspected cleave angle of right fiber Gap Inspected arc gap Offset CutL...

Страница 59: ...the splicer to a tripod to prevent it from dropping Screw hole for M8 screw Screw hole for 1 4 20UNC screw In a high location fix the TYPE 66 to a tripod with the M8 screw or 1 4 20UNC screw on the b...

Страница 60: ...ks If the fibers are breaking when the proof test is performed re do an arc test If the arc power level is too weak the splice may be poor resulting in fiber breaking If the fibers are breaking in spi...

Страница 61: ...d by drop fall or any other faulty treatment such as to be explained in precautions on this manual 3 Damage or malfunction caused by actions that are beyond Sumitomo s control including for example fi...

Страница 62: ...R Measure Turn off the power and turn it on again If the error still persists contact our maintenance service center Cut Error Angle Description L R LR The cleave angle exceeds the allowable level Mea...

Страница 63: ...Description L R LR The fiber is not placed in the V groove properly Measure Place the fiber in the V groove again Fiber Count Error Description L R LR The number of the fiber being spliced is differen...

Страница 64: ...ption Splice Error The spliced portion has a problem Splice Thin Thin Thick 1 The irregularity of the fiber end is high Neck 2 The Overlap value is low Bubble 3 The arc power is strong Thick 1 The irr...

Страница 65: ...rox 45 seconds FPS 6 12 fiber ribbon Approx 75 seconds Splice heat cycles per fully charged battery 4 Approx 80 BU 66S Approx 160 BU 66L Loss Estimation Provided Splice data storage 2 000 splices Func...

Страница 66: ...ng on the temperature and the remaining battery capacity 4 With a new battery 1 splice cycle time splice protection completes in 90 seconds in room temperature A hot jacket remover is not used Splice...

Страница 67: ...57...

Страница 68: ...omo Electric Consulting Sumitomo Electric Lightwave Corp Shanghai Co Ltd 78 Alexander Drive P O Box 13445 Research Triangle park New Delhi India Tel 86 21 6278 5978 NC27709 U S A Sumitomo Electric Ind...

Отзывы: