Clean the wear indicator sensor
Warning: Let the device cool down before you clean the wear indicator
sensor. The device can be hot.
Note:
• Clean the wear indicator sensor to prevent that the device shows incorrect
measurements when you change the oil or when you connect the device to
a different gear unit or hydraulic system.
• Collect the metal particles in a clean container for analysis.
Procedure
1. Drain the oil from the device. Refer to section
on page
26.
2. Remove the wear indicator sensor from the manifold.
3. Use a lint-free cloth to remove all metal particles from the wear indicator sensor.
4. Install the sensor. Refer to section
Install the wear indicator sensor
on page 22.