background image

6

Table 4  Recommended lubricants

Mineral Oil

Synthetic Oil

Brand

BP

CASTROL

CHEVRON

SHELL

TEXACO

TOTAL

ENERGOL

ALPHA

GEAR

COMPOUNS

SPARTAN

MOBIL-

OMALA

MEROPA

CARTER

TRIBOL

ISO VG320
AGMA 6EP

GR-XP-320

SP320

EP320

EP320

GEAR 632

320

OPTIGEAR

BM320

WM 320

EP320

1100/320

EXXON MOBIL

MOBIL GEAR

SHC XMP

320

MOBIL GEAR

SHC 320

ISO VG320

AGMA 6S

EXXONMOBIL

6-4) Oil quantity

An estimated quantity of oil for standard specifications is shown in Table 5. The oil quantity shown in Table 5 and the
catalog is not exact. Use a dipstick or visible oil gauge to check the oil level.

6-5) Oil supply

Supply oil through the filling port atop the main unit. Check the
oil level with a visual oil gauge. (Fig. 4) Exercise care when
supplying oil to ensure that loose nuts, bolts, washers, dust,
water, and other foreign substances will not enter the unit.
If oil level is lower than the specified range, lubrication will be
insufficient. In case the oil level is higher, deterioration of oil is
accelerated due to oil temperature rise.

6-6) Waste oil

Remove the drain plug under the main unit to drain waste oil while it is still warm. 
(i. e. Soon after operation of the unit has ceased. But not immediately after.)

The oil level shall be
within this range.

Fig. 4

Size

Units

liters

gal(US)

SFC060

SFC065

SFC070

SFC075

Oil Quantity

55

70

90

115

14.5

18.5

23.8

30.4

Table 5  Approx. quantity of oil

7. Backstop

Use of a backstop (optional) is to prevent reverse rotation of the cooling fan.
Backstop is located internally. Backstop is lubricated by the internal gear oil.

Brand

Содержание PARAMAX SFC Series

Страница 1: ...y trained technicians Carefully read the maintenance manual before use Oil is removed from PARAMAX DRIVE FOR AIR COOLED CONDENSERS before shipment Supply oil according to the maintenance manual before...

Страница 2: ...garding safety and proper use DANGER CAUTION The unit should be operated only within its design and performance specifications otherwise injury or damage to a system may occur Keep hands and all forei...

Страница 3: ...tor Serial number Fig 1 Rating plate CAUTION Unpack the unit after verifying that it is positioned right side up otherwise injury may result Verify that the unit received is in fact the one ordered Wh...

Страница 4: ...or damage to the equipment and or lifting device may result Before hoisting check the weight with the rating plate crate performance specifications catalog etc Never hoist a PARAMAX DRIVE FOR AIR COOL...

Страница 5: ...n lbs 12390 21510 Install PARAMAX DRIVE FOR AIR COOLED CONDENSERS on a sufficiently rigid base Use installation bolts corresponding to JIS strength class 8 8 or its equivalent The torque of installati...

Страница 6: ...Shaft Shaft end thread Fig 3 Fig 2 6 Lubrication 6 1 Shipping condition 6 2 Method of lubrication 6 3 Selection of lubricant Refer to Table 3 to select mineral oil or synthetic oil Table 4 shows recom...

Страница 7: ...h a visual oil gauge Fig 4 Exercise care when supplying oil to ensure that loose nuts bolts washers dust water and other foreign substances will not enter the unit If oil level is lower than the speci...

Страница 8: ...plug during operation otherwise splashing lubricant may cause burns When reversing the direction of rotation first bring the unit to a complete stop then commence reverse rotation otherwise the system...

Страница 9: ...al operation is still not possible contact the nearest agent distributor or service office 1 Change oil 500 hours or 6 months whichever comes first after initial start up 2 In case of the oil temperat...

Страница 10: ...hop Place the key in position Repair at a specialized workshop Adjust the protective device Change the connection The output shaft turns when there is no load Excessive temperature rise Oil leakage Ab...

Страница 11: ...on shaft Helical gear Helical pinion shaft Key Oil pump Key Key Key Key Tolerance ring Tapered roller bearing Tapered roller bearing Spherical roller bearing Spherical roller bearing Tapered roller be...

Страница 12: ...11 Fig 6 Locations of oil filler and drain plug Oil Filler Oil Gauge Drain Plug Magunetic Plug Air Breather Oil Pump Cooling Fan 13 Locations of oil filler and drain plug...

Страница 13: ...God or any other reasons beyond the control of the Seller 8 waste exhaustion normal wear and tear or deterioration on the parts of the Products such as bearing oil seal 9 any other troubles problems...

Страница 14: ...GM2202E 1 0 2004 2...

Отзывы: