Sumitomo Drive Technologies PARAMAX SFC Series Скачать руководство пользователя страница 2

1

Matters described in                               may lead to serious danger depending on the situation. Be sure to observe
important matters described herein.

DANGER

Transport, installation, plumbing, operation, maintenance, and inspections should be handled by properly
trained technicians ; otherwise, injury or damage to the machine may result.
Do not disassemble PARAMAX Drives FOR AIR COOLED CONDENSERS during operation. Even if it is at 

disassemble any parts other than the oil inlet/outlet when the input/output shafts of the PARAMAX 

DRIVE  FOR  AIR COOLED CONDENSERS  is connected to a motor or other mating machines; otherwise falling 
or operation out of control due to disengagement of gears, as well as death, injury, or damage to the machine may 
result.

Carefully read this maintenance manual and all accompanying documents before use (installation, operation,
maintenance, inspection, etc.). Thoroughly understand the machine, information about safety, and all precautions for
correct operation. 
Maintain this manual for future reference.
Pay particular attention to the "DANGER" and "CAUTION" warnings regarding safety and proper use.

DANGER

CAUTION

The unit should be operated only within its design and performance specifications ; otherwise, injury or
damage to a system may occur.
Keep hands and all foreign objects from the internal moving parts of the unit ;  otherwise, injury or damage to
a system may occur.
Damaged units should be taken off - line and not put back in operation until properly repaired.
Any modifications or alterations of any kind, to the unit, will void the warranty and all subsequent claims.
Do not remove the rating plate.

CAUTION

CAUTION

CONTENTS

Safety and other precautions.......................1

1. Inspection upon delivery ............................ 2

2. Storage....................................................... 3

3. Transport .....................................................3

4. Installation .................................................. 3

5. Coupling with other machines .................... 4

6. Lubrication.................................................. 5

7. Backstop..................................................... 6

8. Operation ................................................... 7

9. Daily inspection and maintenance ............. 8

10. Troubleshooting ......................................... 9

11. Disassembly/reassembly and disposal ...... 9

12. Construction drawing ............................... 10

13. Locations of oil filler and drain plug ...........11

14. Warranty................................................... 12

Oil has been removed from PARAMAX DRIVE FOR 

AIR COOLED CONDENSERS

  before shipment from our 

factory, so supply recommended oil before use.

: Improper handling may result in physical damage, serious personal injury and/or

death.

: Improper handling may result in physical damage and/or personal injury.

(Safety and other precautions)

  rest, do not

Содержание PARAMAX SFC Series

Страница 1: ...y trained technicians Carefully read the maintenance manual before use Oil is removed from PARAMAX DRIVE FOR AIR COOLED CONDENSERS before shipment Supply oil according to the maintenance manual before...

Страница 2: ...garding safety and proper use DANGER CAUTION The unit should be operated only within its design and performance specifications otherwise injury or damage to a system may occur Keep hands and all forei...

Страница 3: ...tor Serial number Fig 1 Rating plate CAUTION Unpack the unit after verifying that it is positioned right side up otherwise injury may result Verify that the unit received is in fact the one ordered Wh...

Страница 4: ...or damage to the equipment and or lifting device may result Before hoisting check the weight with the rating plate crate performance specifications catalog etc Never hoist a PARAMAX DRIVE FOR AIR COOL...

Страница 5: ...n lbs 12390 21510 Install PARAMAX DRIVE FOR AIR COOLED CONDENSERS on a sufficiently rigid base Use installation bolts corresponding to JIS strength class 8 8 or its equivalent The torque of installati...

Страница 6: ...Shaft Shaft end thread Fig 3 Fig 2 6 Lubrication 6 1 Shipping condition 6 2 Method of lubrication 6 3 Selection of lubricant Refer to Table 3 to select mineral oil or synthetic oil Table 4 shows recom...

Страница 7: ...h a visual oil gauge Fig 4 Exercise care when supplying oil to ensure that loose nuts bolts washers dust water and other foreign substances will not enter the unit If oil level is lower than the speci...

Страница 8: ...plug during operation otherwise splashing lubricant may cause burns When reversing the direction of rotation first bring the unit to a complete stop then commence reverse rotation otherwise the system...

Страница 9: ...al operation is still not possible contact the nearest agent distributor or service office 1 Change oil 500 hours or 6 months whichever comes first after initial start up 2 In case of the oil temperat...

Страница 10: ...hop Place the key in position Repair at a specialized workshop Adjust the protective device Change the connection The output shaft turns when there is no load Excessive temperature rise Oil leakage Ab...

Страница 11: ...on shaft Helical gear Helical pinion shaft Key Oil pump Key Key Key Key Tolerance ring Tapered roller bearing Tapered roller bearing Spherical roller bearing Spherical roller bearing Tapered roller be...

Страница 12: ...11 Fig 6 Locations of oil filler and drain plug Oil Filler Oil Gauge Drain Plug Magunetic Plug Air Breather Oil Pump Cooling Fan 13 Locations of oil filler and drain plug...

Страница 13: ...God or any other reasons beyond the control of the Seller 8 waste exhaustion normal wear and tear or deterioration on the parts of the Products such as bearing oil seal 9 any other troubles problems...

Страница 14: ...GM2202E 1 0 2004 2...

Отзывы: