SPP id: Version 14 > / 140901 / Replaces 140530 / en /
N32198
/ 3 / Page 2 (27)
Series
2.15
INSTRUCTIONS
September 2014
Page
ISO
G
COPYRIGHT © SULZER PUMPS FINLAND OY
ORIGINAL INSTRUCTION
USER'S MANUAL – AHLSTAR
Corrective maintenance
1 General
N O T E
Refer to the sectional drawings when reading through these instructions.
1.1 Safety instructions and environmental aspects to be noted before corrective
maintenance
W A R N I N G
When pumping hazardous liquids, secure that there is no trapped liquid remaining in pump parts.
Pumps which convey hazardous media must be carefully decontaminated before any repairs. Skin and
eye protection are required during decontamination. Precautions are needed for personal or
environmental safety.
Some of the disassembled parts and assemblies are heavy, unstable and due to design requirements
they contain sharp edges (e.g. impeller, sideplate, casing cover). Use proper hoistings and supports to
prevent personal injury.
W A R N I N G
Hazardous substances must be kept away from the environment. These substances should be
collected and sent for proper handling. All recyclable components should be taken to a proper
recycling system.
1.2 Necessary equipment / tools
Normally available working tools
Hoisting accessories. Note the safety requirements!
Wrenches for hexagonal screws, sizes (mm): 13, 14, 16, 18, 19, 22, 24, 30, 36
Allen wrenches for socket head screws, sizes (mm): 2,5, 4, 5, 6, 8, 10, 14
Torque wrenches for moments (Nm): 30, 50, 130, 250, 420, 800
- for hexagonal, sizes (mm): 18, 24, 30, 36
- for socket head, sizes (mm): 8, 10, 14, 17, 19, 22, 27
Hooked wrenches, sizes (SKF): HN8, HN10, HN12, HN14, HN18, HN22, HN26
Extractors
Bearing
heater
Dial
indicators
Cleaning agents & equipment
Lubricating agents & equipment