USER'S MANUAL – AHLSTAR
Preventive maintenance
COPYRIGHT © SULZER PUMPS FINLAND OY
ORIGINAL INSTRUCTION
If the environment temperature is below 0 °C, oil splash lubrication shouldn’t be used.
First oil filling (Oil splash lubrication)
Remove the venting device (672.31) and add oil so that the level reaches the middle of the sight glass
(642.31).
Loose the socket head screw (914.31) and remove the constant level oiler (638.31). Fill it with oil and put it
back.
First oil filling (Oil bath lubrication)
Without using the constant level oiler
Fig. 5
Unscrew the venting device (672.31) and add oil up to the middle of the sight glass (642.31), Fig. 5. When pump is
running oil level in the sight glass can be little variable. With lower speed oil level can go little bit lower and higher
speed go little up (air is mixing into oil. Screw the venting device (672.31) back in place. See the oil volumes in Table
8.
With using the constant level oiler
Fig. 6
Install the constant level oiler (638.31) in the bearing unit. Adjust the constant level oiler (638.31) to the correct
height (0 mm) and tighten the locking screw. Unscrew the venting device (672.31), add oil up to the middle of the
sight glass (642.31) and screw the venting device (672.31) back in place. Undo the glass cup of the constant level
oiler (638.31) and fill it with oil, and place the glass cup of the constant level oiler (638.31) back in place.
0
638.21
642.31
672.31
642.31