SPP id: Version 14 > / 131130 / Replaces 130131 / en /
N31571
/ 4 / Page 18 (19)
Series
2.15
INSTRUCTIONS
November 2013
Page
ISO
G
COPYRIGHT © SULZER PUMPS FINLAND OY
ORIGINAL INSTRUCTION
USER'S MANUAL – AHLSTAR
Installation at the site
Fig. 18,
Baseplate for pump and motor, Rectangular (STD)
Pump mounting sizes 5J, 5K, 5L, 63, 64, 65, 66, 67, 68, 74, 75, 77, 78, 79, 7A, 7B, 7C,
7D
5.3 Steel baseplate installed with mechanical feet
Fasten each machine base (963.61) into the fixing holes in the baseplate and install the washers (554.66) under the
hexagonal nuts. There are 3, 4, 5 or 6 fixing holes. Use the studs in the machine bases to adjust the baseplate to the
correct height and horizontally, and tighten the hexagonal nuts.
Fig. 19
L1 + min. 110, when
L1
≤
2000
L1 + min. 140, when
L1 > 2000
B2 + min. 110, when
L1
≤
2000
B2 + min. 140, when
L1 > 2000
5 mm