TSR32 USER MANUAL R00
SECTION 4
36
4.8
MOTOR ROTATION
DIRECTION CHECK
Motor rotation check must be done at compressor
start-up after the wiring has been installed. The
compressor can be damaged if it runs in the wrong
direction for more than a few seconds. Motor rotation
can be viewed through the opening in the drive
adapter housing. Pull out the EMERGENCY STOP
button and press once, quickly and in succession,
the
(START) and
(STOP) pads. This
action will bump start the motor. When looking from
the motor end opposite the compressor unit, the
shaft should turn clockwise. If reverse rotation
occurs, disconnect the power to the starter and
exchange any two of the three power input leads,
then re-check rotation. A "Direction of Rotation"
nameplate is located on the motor/compressor
adapter to show proper motor/compressor rotation.
Fan motor rotation should also be checked. It should
rotate counter-clockwise when viewing the fan motor
from the backside of the motor.
Содержание TSR20
Страница 10: ...NOTES 10...
Страница 12: ...TSR32 USER MANUAL R00 SECTION 2 12 Figure 2 1 Sullair TSR 32 Rotary Screw Air Compressor Air Cooled VSD...
Страница 13: ...SECTION 2 TSR32 USER MANUAL R00 13 Figure 2 2 Sullair TSR 32 Rotary Screw Air Compressor Air Cooled Fixed Speed...
Страница 17: ...SECTION 2 TSR32 USER MANUAL R00 17...
Страница 20: ...TSR32 USER MANUAL R00 SECTION 2 20 Figure 2 6 TSR 32 Piping and Instrumentation VSD 02250177 348 R01...
Страница 22: ...TSR32 USER MANUAL R00 SECTION 2 22 Figure 2 7 TSR 32 Piping and Instrumentation Fixed Speed 02250177 349 R01...
Страница 24: ...NOTES 24...
Страница 27: ...NOTES 27...
Страница 28: ...TSR32 USER MANUAL R00 SECTION 3 28 02250175 423 R01...
Страница 29: ...SECTION 3 TSR32 USER MANUAL R00 29 02250177 017 R01...
Страница 30: ...TSR32 USER MANUAL R00 SECTION 3 30 Figure 3 4 Wiring 02250177 397 R00...
Страница 31: ...SECTION 3 TSR32 USER MANUAL R00 31 02250177 398 R00...
Страница 32: ...NOTES 32...
Страница 46: ...NOTES 46...
Страница 47: ...NOTES 47...