TSR32 USER MANUAL R00
SECTION 6
44
Compressor Shuts Down With
Air Demand Present
Loss of control voltage
Check incoming power
Low incoming voltage
Check control fuses and wiring. Consult power
will provide indication of most maintenance
problems if control power has not been lost.
Shutdowns will occur upon a faulty condition or
a bad sensor condition.
Excessive operating pressure
Check maximum P2 pressure setting.
HIGH PRESS P1 display; Max P1 pressure
may be set too low. Consult factory for
recalibration.
Defective solenoid valve; solenoid valve
should cause Sullicon Control lever to move to
unload stop when the unload pressure setting
P2A is exceeded. Repair if defective.
Defective blowdown valve; blowdown valve
should exhaust sump pressure to 30 psig (2.1
bar) for integrated coolers; 50 psig (3.4 bar) for
remote coolers when maximum operating
pressure is reached. Repair if defective.
Open or shorted P1, P2, P3 or P4 sensor
message; replace sensor indicated.
Operating lever of inlet butterfly valve is loose
on valve shaft. Reposition the valve plate and
tighten lever set screw.
HIGH TEMP T1 or T3 Message
Displayed
Cooling air flow restricted; clean cooler and
check for proper ventilation.
Ambient temperature is too high; provide
sufficient ventilation.
Low fluid level; add fluid.
Clogged fluid filter; change the fluid filter
element as indicated by Supervisor
Thermal valve not functioning properly; replace
element.
Open or shorted T1 or T2 sensor; check for a
short or open circuit to probe and correct
wiring.
Low fluid pressure (LOW
PRESSURE P3 DISPLAY)
Check fluid level.
Check for clogged fluid filter.
Cooling fan motor (FAN OL
display)
Check the cooling fan motor.
Table 6-1: Troubleshooting Guide
SYMPTOM
PROBABLE CAUSE
REMEDY
Содержание TSR20
Страница 10: ...NOTES 10...
Страница 12: ...TSR32 USER MANUAL R00 SECTION 2 12 Figure 2 1 Sullair TSR 32 Rotary Screw Air Compressor Air Cooled VSD...
Страница 13: ...SECTION 2 TSR32 USER MANUAL R00 13 Figure 2 2 Sullair TSR 32 Rotary Screw Air Compressor Air Cooled Fixed Speed...
Страница 17: ...SECTION 2 TSR32 USER MANUAL R00 17...
Страница 20: ...TSR32 USER MANUAL R00 SECTION 2 20 Figure 2 6 TSR 32 Piping and Instrumentation VSD 02250177 348 R01...
Страница 22: ...TSR32 USER MANUAL R00 SECTION 2 22 Figure 2 7 TSR 32 Piping and Instrumentation Fixed Speed 02250177 349 R01...
Страница 24: ...NOTES 24...
Страница 27: ...NOTES 27...
Страница 28: ...TSR32 USER MANUAL R00 SECTION 3 28 02250175 423 R01...
Страница 29: ...SECTION 3 TSR32 USER MANUAL R00 29 02250177 017 R01...
Страница 30: ...TSR32 USER MANUAL R00 SECTION 3 30 Figure 3 4 Wiring 02250177 397 R00...
Страница 31: ...SECTION 3 TSR32 USER MANUAL R00 31 02250177 398 R00...
Страница 32: ...NOTES 32...
Страница 46: ...NOTES 46...
Страница 47: ...NOTES 47...