Compressor Shuts Down With 
Air Demand Present

Loss of control voltage

Check incoming power

Low incoming voltage

Check control fuses and wiring. Consult power 

will provide indication of most maintenance 
problems if control power has not been lost. 
Shutdowns will occur upon a faulty condition or 
a bad sensor condition.

Excessive operating pressure

Check maximum P2 pressure setting.

HIGH PRESS P1 display; Max P1 pressure 
may be set too low. Consult factory for 
recalibration.

Defective solenoid valve; solenoid valve 
should cause Sullicon Control lever to move to 
unload stop when the unload pressure setting 
P2A is exceeded. Repair if defective.

Defective blowdown valve; blowdown valve 
should exhaust sump pressure to 30 psig (2.1 
bar) for integrated coolers; 50 psig (3.4 bar) for 
remote coolers when maximum operating 
pressure is reached. Repair if defective.

Open or shorted P1, P2, P3 or P4 sensor 
message; replace sensor indicated.

Operating lever of inlet butterfly valve is loose 
on valve shaft. Reposition the valve plate and 
tighten lever set screw.

HIGH TEMP T1 or T3 Message 
Displayed

Cooling air flow restricted; clean cooler and 
check for proper ventilation.

Ambient temperature is too high; provide 
sufficient ventilation.

Low fluid level; add fluid.

Clogged fluid filter; change the fluid filter 
element as indicated by Supervisor 

Thermal valve not functioning properly; replace 
element.

Open or shorted T1 or T2 sensor; check for a 
short or open circuit to probe and correct 
wiring.

Low fluid pressure (LOW 
PRESSURE P3 DISPLAY)

Check fluid level.

Check for clogged fluid filter.

Cooling fan motor (FAN OL 
display)

Check the cooling fan motor.

Table 6-1: Troubleshooting Guide

SYMPTOM

PROBABLE CAUSE

REMEDY

Содержание TSR20

Страница 1: ...Y NOTICE PART NUMBER KEEP FOR FUTURE REFERENCE USER MANUAL SULLAIR CORPORATION The information in this manual is current as of its publication date and applies to compressor serial number and all subs...

Страница 2: ...City Indiana Instruction includes training on the function and installation of Sullair service parts troubleshooting common faults and malfunctions and actual equipment operation These seminars are r...

Страница 3: ...ING 9 1 10 ENTRAPMENT 11 2 1 INTRODUCTION 11 2 2 COMPRESSOR COMPONENT DESCRIPTION 15 2 3 COMPRESSOR COOLING AND AL DESCRIPTION 15 2 4 COMPRESSOR DISCHARGE SYST 15 2 5 VSD CONTROL SYSTEM 18 2 6 FIXED S...

Страница 4: ...4 4 6 FLUID LEVEL CHECK 35 4 7 ELECTRICAL PREPARATION 36 4 8 MOTOR ROTATION DIRECTION CHECK 37 5 1 ROUTINE OPERATION SETUP 39 6 1 GENERAL 39 6 2 MAINTENANCE AFTER INITIAL 50 HOURS OF OPERATION 39 6 3...

Страница 5: ...rein are applicable to most compressors and the concepts behind these statements are generally applicable to all compressors 1 2 PERSONAL PROTECTIVE EQUIPMENT A Prior to installing or operating the co...

Страница 6: ...including air line anti icer system antifreeze compound or fluid film to accumulate on under or around acoustical mate rial or on any external surfaces of the air com pressor Wipe down using an aqueo...

Страница 7: ...codes or regula tions B DO NOT use air line anti icer systems in air lines supplying respirators or other breathing air utili zation equipment and DO NOT discharge air from these systems into unventi...

Страница 8: ...otating machinery and prior to handling any ungrounded conductors 1 9 LIFTING A If the compressor is provided with a lifting bail then lift by the bail provided If no bail is provided then lift by sli...

Страница 9: ...a cles at floor level and transport and corner at minimum practical speeds N Make sure pallet mounted compressors are firmly bolted or otherwise secured to the pallet prior to attempting to forklift o...

Страница 10: ...NOTES 10...

Страница 11: ...directly with the air as the rotors turn which compresses the air The fluid flow has three basic functions 1 As a coolant it controls the air temperature rise normally associated with the heat of comp...

Страница 12: ...TSR32 USER MANUAL R00 SECTION 2 12 Figure 2 1 Sullair TSR 32 Rotary Screw Air Compressor Air Cooled VSD...

Страница 13: ...SECTION 2 TSR32 USER MANUAL R00 13 Figure 2 2 Sullair TSR 32 Rotary Screw Air Compressor Air Cooled Fixed Speed...

Страница 14: ...TO FLUID COOLER CC FROM FLUID COOLER DD TO UNIT INJECTION BLOCK EE TO AFTERCOOLER FF FROM AFTERCOOLER GG AIR SUPPLY OUTLET HH MOISTURE DRAIN OUTLET 1 FLUID FILTER 2 FLUID STOP VALVE 3 MINIMUM PRESSUR...

Страница 15: ...amount of fluid remaining in the compressed air collects on the surface of the separator elements as the air flows through the separators Two return lines or scavenge tube lead from the bottom of the...

Страница 16: ...solenoid valve opens feeding air pressure to the spiral valve actuator This in turn expands the diaphragm and engages the pinion mounted on the spiral valve shaft assembly resulting in a rotary motio...

Страница 17: ...SECTION 2 TSR32 USER MANUAL R00 17...

Страница 18: ...tor for the spiral valve gradually opens apply ing air pressure to the spiral valve actuator Air pressure at the actuator expands the diaphragm The rack in turn engages with the pinion mounted on the...

Страница 19: ...be disabled in the Supervisor modulation is disabled the unload pressure must be reset to the rated load pressure of the machine For example an L model rated for 100 psig full load operation and 110 p...

Страница 20: ...TSR32 USER MANUAL R00 SECTION 2 20 Figure 2 6 TSR 32 Piping and Instrumentation VSD 02250177 348 R01...

Страница 21: ...ELEMENT SECONDARY SEPARATOR 22 250034 123 1 ELEMENT PRIMARY SEPARATOR 23 02250117 009 2 GAUGE PRESSURE PLEASE NOTE WHEN ORDERING PARTS INDICATE SERIAL NUMBER OF COMPRESSOR 28 02250097 611 2 GLASS FLUI...

Страница 22: ...TSR32 USER MANUAL R00 SECTION 2 22 Figure 2 7 TSR 32 Piping and Instrumentation Fixed Speed 02250177 349 R01...

Страница 23: ...4 129 1 ELEMENT SECONDARY SEPARATOR 22 250034 123 1 ELEMENT PRIMARY SEPARATOR 23 02250117 009 2 GAUGE PRESSURE PLEASE NOTE WHEN ORDERING PARTS INDICATE SERIAL NUMBER OF COMPRESSOR 28 02250097 611 2 GL...

Страница 24: ...NOTES 24...

Страница 25: ...0 MOTOR TEFC HZ VOLTAGE 460 60 DRIVE AMP RATING 385A WEIGHT lbs 19 900 LENGTH in 220 WIDTH in 84 HEIGHT in 104 COMPRESSOR TSR 32 Type Rotary Screw Standard Operating Pressure 100 psig 7 bar 125 psig 9...

Страница 26: ...oam ing filter plugging or orifice line obstruc tion CAUTION Do not mix different types of lubricants Mixing lubricants can cause malfunctions or compressor damage will void the com 1 Fluid Fill Port...

Страница 27: ...NOTES 27...

Страница 28: ...TSR32 USER MANUAL R00 SECTION 3 28 02250175 423 R01...

Страница 29: ...SECTION 3 TSR32 USER MANUAL R00 29 02250177 017 R01...

Страница 30: ...TSR32 USER MANUAL R00 SECTION 3 30 Figure 3 4 Wiring 02250177 397 R00...

Страница 31: ...SECTION 3 TSR32 USER MANUAL R00 31 02250177 398 R00...

Страница 32: ...NOTES 32...

Страница 33: ...mponents faces absorb sound and reduce ambient noise levels Hard surfaces reflect noise and have little effect on ambient noise lev els 4 2 VENTILATION AND COOLING AIR COOLED COMPRESSORS clearance aro...

Страница 34: ...iver Compressors have built in aftercoolers and are equipped with a condensate drain located next to the air outlet connection A drain line should be installed to remove the condensate which builds up...

Страница 35: ...from a suitable electrical power source is critical because voltage drops can adversely effect the performance of the compressor Refer to Table 4 2 Motor Wiring Basic Data Parallel feeder cable connec...

Страница 36: ...once quickly and in succession the START and STOP pads This action will bump start the motor When looking from the motor end opposite the compressor unit the shaft should turn clockwise If reverse ro...

Страница 37: ...6 8 Troubleshooting Introduction on page 43 under EXCESSIVE COMPRESSOR FLUID CONSUMPTION for a probable cause and corrective action After a routine start observe the controller display for the proper...

Страница 38: ...0XH 175 PSIG TSR32_300L 100 PSIG TSR32_300H 125 PSIG TSR32_300HH 150 PSIG TSR32_300XH 175 PSIG Cooling Air Press Trans 250PSI P1 Max Maximum discharge pressure KT Fluid No Water Switch No Oil Switch N...

Страница 39: ...d Piping System 2 Replace the fluid filter element 6 4 FLUID MAINTENANCE Drain the receiver tank and change the compressor fluid using instructions shown in the Lubrication Guide 6 5 FILTER MAINTENANC...

Страница 40: ...ELEMENT REPLACEMENT Element replacement is performed by reversing the removal instructions Make sure that the element is fully seated into the housing 6 7 SEPARATOR MAINTENANCE Replace the separator...

Страница 41: ...ssor 11 Check the return line strainer before re start ing the compressor If needed either clean or replace the strainer FLUID RETURN SIGHT GLASS MAINTENANCE Refer to Figure 6 4 The fluid return sight...

Страница 42: ...406480 or order repair kit 250031 271 Figure 6 4 Fluid Return Sight Glass 1 Tube Connectors 2 Filter Assembly I 3 Sight Glass Orifice Block 4 Secondary Element orifice 03 5 Primary Element orifice 09...

Страница 43: ...ng element from the coupling jaws 5 Install the new element by wrapping it around the jaws engaging the cogs on the element into the jaws 6 Reinstall the outer sleeve and secure by tightening the two...

Страница 44: ...ar for integrated coolers 50 psig 3 4 bar for remote coolers when maximum operating pressure is reached Repair if defective Open or shorted P1 P2 P3 or P4 sensor message replace sensor indicated Opera...

Страница 45: ...place if necessary kit available Ruptured Sullicon control diaphragm Replace Plugged control line filter Clean or repair if necessary Excessive Fluid Consumption Clogged return line strainer or orific...