SECTION 6
TSR32 USER MANUAL R00
43
C
ONTROL
L
INE
F
ILTER
The regulators and solenoid valves, which control the
compressor, are protected by a control line filter.
Remove the bowl and verify condition of element and
drain-float. Replace if needed, do not clean element,
with element/seal kit (02250153-288) and/or float
assembly/seal kit (02250153-280).
S
HAFT
C
OUPLING
M
AINTENANCE
The compressor unit and motor are rigidly connected
through the mounting adapter housing. This
arrangement
makes
coupling
alignment
unnecessary. The coupling is a jaw type in shear. If
the
elastomeric
(rubber)
element
requires
replacement due to wear or damage, order a
replacement element and perform the following
steps:
1. Remove the protective grill from the adapter
housing.
2. Loosen the retaining screw located on the
outer sleeve. Slide the sleeve to one side,
exposing the coupling element.
3. Unwrap the coupling element from the
coupling jaws.
5. Install the new element by wrapping it
around the jaws, engaging the cogs on the
element into the jaws.
6. Reinstall the outer sleeve and secure by
tightening the two screws to 45 in·lbs (5 Nm).
7. Reinstall the protective grill.
INTRODUCTION
The information in the Troubleshooting Guide
describe symptoms and usual causes for the listed
discrepancies. However,
DO NOT
assume that these
are the only malfunctions or fault conditions that may
occur.
NOTE
For additional troubleshooting guidelines,
ual.
Table 6-1: Troubleshooting Guide
SYMPTOM
PROBABLE CAUSE
REMEDY
Compressor will not start
Main disconnect switch open
Close switch.
Line fuse blown
Replace fuse.
Control Transformer Fuse Blown
Reset. Should trouble persist, check whether
motor starter contacts are functioning properly.
Motor Starter Overloads Tripped
Check voltage. Should voltage check low,
consult power company.
module if no display or erratic
display.
Replace
Low incoming line voltage
Check voltage. Should voltage check low,
consult power company.
module if no display or erratic display.
Содержание TSR20
Страница 10: ...NOTES 10...
Страница 12: ...TSR32 USER MANUAL R00 SECTION 2 12 Figure 2 1 Sullair TSR 32 Rotary Screw Air Compressor Air Cooled VSD...
Страница 13: ...SECTION 2 TSR32 USER MANUAL R00 13 Figure 2 2 Sullair TSR 32 Rotary Screw Air Compressor Air Cooled Fixed Speed...
Страница 17: ...SECTION 2 TSR32 USER MANUAL R00 17...
Страница 20: ...TSR32 USER MANUAL R00 SECTION 2 20 Figure 2 6 TSR 32 Piping and Instrumentation VSD 02250177 348 R01...
Страница 22: ...TSR32 USER MANUAL R00 SECTION 2 22 Figure 2 7 TSR 32 Piping and Instrumentation Fixed Speed 02250177 349 R01...
Страница 24: ...NOTES 24...
Страница 27: ...NOTES 27...
Страница 28: ...TSR32 USER MANUAL R00 SECTION 3 28 02250175 423 R01...
Страница 29: ...SECTION 3 TSR32 USER MANUAL R00 29 02250177 017 R01...
Страница 30: ...TSR32 USER MANUAL R00 SECTION 3 30 Figure 3 4 Wiring 02250177 397 R00...
Страница 31: ...SECTION 3 TSR32 USER MANUAL R00 31 02250177 398 R00...
Страница 32: ...NOTES 32...
Страница 46: ...NOTES 46...
Страница 47: ...NOTES 47...