4: Installation

SN55, SN55S, SN55V, SN75, SN75S, SN75V User Manual

02250247-571 R04

59

Subject to EAR, ECCN EAR99 and related export control restrictions.

trap. A drain line should be installed on the condensate
drain.

4.5

Coupling alignment check

No coupling alignment is required.

4.6

Fluid level check

The air compressor is shipped with the proper amount of
fluid installed. However, it is necessary to check the fluid
level at the time of installation and during continued oper-
ation of the compressor. The fluid level is to be checked
when the compressor is in the 

SHUT DOWN

 mode (fluid

level may not be visible when operating), and by looking
at the sight glass on the separator/sump tank. To be able
to see the fluid level it may be necessary to start the
machine and build the separator/sump tank pressure up
to 10/20 psi and then shut down. Wait a few minutes to
check oil level. If no fluid level is seen in the sight glass
add fluid to the center of the glass. Do not overfill in any
case. When a complete fluid change is performed, fill the
separator/sump tank to the maximum allowable fluid
level, which is center of the sight glass.

4.7

Electrical preparation

Interior electrical wiring is performed at the factory.
Required customer wiring should be done by a qualified
electrician in compliance with OSHA, National Electric
Code and/or any applicable local electrical code concern-
ing isolation switches, fused disconnects, etc. Sullair pro-
vides a wiring diagram for use by the installer. An
electrical check should be made to help assure that the
first start-up will be trouble-free. The compressor and
drive should be properly grounded/earthed in accordance
with Local and National Code requirements.

Installation of this compressor must be in accordance
with recognized electrical codes and any local Health and
Safety Codes.

Feeder cables should be sized by the customer/electrical
contractor to ensure that the circuit is balanced and not
overloaded by other electrical equipment. The length of
wiring from a suitable electrical feed point is critical as

voltage drops may impair the performance of the com-
pressor. Cable sizes may vary considerably so the mains
terminals will accept up to 50 mm2 (1 awg) (37/4 Sk &
50/60 H) and up to 90 mm2 (3/0 awg) (55/75 k & 75/
100 H) cable.

Feeder cable connections to incoming terminals L1-L2-
L3 should be tight and clean.

The applied voltage must be compatible with the motor
and compressor data plate ratings.

A starter hole is provided for incoming power connection.
If it is necessary to make a hole in the control box in a dif-
ferent location, care should be taken to not allow metal
shavings to enter the starter and other electrical compo-
nents within the box. If another hole is used, the original
hole must be blocked off.

1. Check incoming voltage. Be sure that the incom-

ing voltage is the same voltage that the compres-
sor was wired for.

2. Check motor starter and overload heater sizes.
3. Check all electrical connections for tightness.
4. Check the electrical controls by disconnecting

the three (3) motor leads from the starter. Ener-
gize the control circuits by pushing the Start but-
ton and check all protective devices to be sure
that they will de-energize the starter coil when
tripped.

5. Reconnect the three (3) motor leads and jog the

motor for a direction of rotation check, as
explained in 

Section 4.8: Motor rotation direction

check

 on page 59.

4.8

Motor rotation direction check

Motor rotation check must be made at compressor start-
up. The compressor can be damaged if it runs in the
wrong direction for more than a few seconds. Motor rota-
tion can be viewed through the opening in the drive
adapter housing. After the electrical wiring has been
done, it is necessary to check the direction of the motor
rotation. Pull out the 

EMERGENCY STOP

 button and

press once, quickly and in succession, the Start and Stop
buttons. This action will bump start the motor for a very
short time. When looking at the motor from the end oppo-

 NOTE

For low-volume systems that do not require an 
auxiliary separator/sump, compressor response 
time may need to be adjusted. Consult the Sul-
lair Service Department for assistance.

 DANGER

Lethal shock hazard inside. Disconnect all 
power at source before opening or servicing.

Содержание SN55

Страница 1: ...03 27 2020 Copyright 2020 Sullair LLC All rights reserved WARRANTY NOTICE Failure to follow the instructions and procedures in this manual or misuse of this equipment will void its warranty Subject to...

Страница 2: ...ing on the function and installation of Sullair service parts troubleshooting common faults and malfunctions and actual equipment operation These courses are recommended for distributor service person...

Страница 3: ...pressor unit functional description 14 2 4 Compressor cooling and lubrication system functional description 17 2 5 Compressor discharge system functional description 17 2 6 Control system functional d...

Страница 4: ...ndations 56 4 2 5 1 Scale 56 4 2 5 2 Corrosion 56 4 2 5 3 Biological and organic fouling slime 56 4 2 6 Seawater cooled units 56 4 3 Outdoor installation sheltered 57 4 4 Service air piping 57 4 4 1 P...

Страница 5: ...tions 4 6 7 Separator maintenance 72 6 7 1 Separator element replacement 72 6 8 Oil return sight glass maintenance 73 6 9 Pressure regulator adjustment 73 6 10 Water condensate drain maintenance 74 6...

Страница 6: ...Table of Contents SN55 SN55S SN55V SN75 SN75S SN75V User Manual Notes 02250247 571 R04 5 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 7: ...plicable to most compressors and the concepts behind these state ments are generally applicable to all compressors 1 2 Personal protective equipment A Prior to installing or operating the compressor o...

Страница 8: ...rial or on any external surfaces of the air compressor Wipe down using an aqueous industrial cleaner or steam clean as required If necessary remove acoustical mate rial clean all surfaces and then rep...

Страница 9: ...in this compressor are typical of the industry Care should be taken to avoid accidental ingestion and or skin contact In the event of ingestion seek medical treatment promptly Wash with soap and water...

Страница 10: ...ep all personnel out from under and away from the compressor whenever it is suspended H Lift compressor no higher than necessary I Keep lift operator in constant attendance whenever compressor is susp...

Страница 11: ...ce using the proper energy isolating devices and tags Place lockout hasp and padlock or tag at the point of power disconnect where lockout is required by each person performing work Each person shall...

Страница 12: ...published service manuals Failure to observe this precau tion could result in death or severe injury WARNING Line terminals L1 L2 L3 motor terminals U V W and the DC link brake resistor terminals are...

Страница 13: ...to the util ity line power as severe damage to the VSD may occur NOTE Interior electrical wiring is performed at the fac tory Required customer wiring is minimal but should be done by a qualified elec...

Страница 14: ...1 Safety SN55 SN55S SN55V SN75 SN75S SN75V User Manual Notes 02250247 571 R04 13 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 15: ...ed from the fluid Another similar heat exchanger cools the compressed air Both air cooled and water cooled versions have easily accessible items such as the fluid filter air oil separator and control...

Страница 16: ...lated export control restrictions Figure 2 1 Overall component layout air cooled model 1 Compressor unit 8 Moisture separator 2 Motor 9 Fluid filter 3 Cooler fan motor 10 Fluid fill 4 Electrical enclo...

Страница 17: ...control restrictions 16 Figure 2 2 Overall component layout water cooled model 1 Compressor unit 8 Moisture separator 2 Motor 9 Fluid filter 3 Oil cooler 10 Fluid fill 4 Electrical enclosure 11 Fluid...

Страница 18: ...nal baffle system The direction of movement is changed and its velocity significantly reduced thus causing large droplets of fluid to form and fall to the bottom of the separator sump tank The fractio...

Страница 19: ...Description 02250247 571 R04 Subject to EAR ECCN EAR99 and related export control restrictions 18 Figure 2 3 Air cooled cooling lubrication and discharge system 1 Compressor unit 4 Moisture separator...

Страница 20: ...al 02250247 571 R04 19 Subject to EAR ECCN EAR99 and related export control restrictions Figure 2 4 Water cooled cooling lubrication and discharge system 1 Compressor unit 4 Moisture separator 2 Separ...

Страница 21: ...e at the actuator expands the dia phragm The rack in turn engages with the pinion mounted on the spiral valve shaft assembly This results in a rotary motion As the spiral valve rotates it starts openi...

Страница 22: ...and related export control restrictions Automatic operation For applications with varied periods of time when there are no air requirements the controller s AUTOMATIC mode allows the compressor to sh...

Страница 23: ...bject to EAR ECCN EAR99 and related export control restrictions 22 Figure 2 5 Standard pneumatic control system 1 Air inlet 5 Air outlet 2 Minimum pressure check valve 6 Pressure regulator 3 Blowdown...

Страница 24: ...response to the operation of the pressure regulator Refer to Full load mode 50 to 100 psig 3 4 to 6 9 bar on page 20 The inlet valve also acts as a check valve thus preventing reverse rotation when th...

Страница 25: ...imum pressure valve opens allowing compressed air to flow into to the service line From this point on the controller monitors the line pressure which controls the VSD The pressure regulator and soleno...

Страница 26: ...2 Description SN55 SN55S SN55V SN75 SN75S SN75V User Manual Notes 02250247 571 R04 25 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 27: ...55 87 6 2225 43 4 1103 68 5 1740 3455 1570 5510S 75 55 87 6 2225 43 4 1103 68 5 1740 3455 1570 5512S 75 55 87 6 2225 43 4 1103 68 5 1740 3455 1570 SN75 series 7507 100 75 87 6 2225 43 4 1103 68 5 1740...

Страница 28: ...SN55V models 5507V through 5512V TEFC 460 60 72 87 6 2225 43 4 1103 68 5 1740 3411 1550 575 60 62 87 6 2225 43 4 1103 68 5 1740 3411 1550 VSD series SN75V models 7507V through 7512V TEFC 460 60 88 87...

Страница 29: ...chscreen Controller 7 touchscreen 1 Special compressors are available for operation in higher ambient temperature Motor Standard models Size 75 100 hp 55 75 kW Type C flanged totally enclosed fan cool...

Страница 30: ...gging When ambient conditions exceed those noted or if condi tions warrant use of extended life lubricants contact Sul lair for recommendation 3 6 Application guide Sullair encourages the user to part...

Страница 31: ...Separator change Sullube 7 2 gal 27 3 L E G C I D PristineFG 7 2 gal 27 3 L H E G C B D B 4 000 hours or more frequently if conditions so require C When measured pressure loss exceeds 20 psig 1 3 bar...

Страница 32: ...3 Specifications SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 31 Subject to EAR ECCN EAR99 and related export control restrictions 3 8 Identification air cooled 02250242 484 R02...

Страница 33: ...EE CIRCULATION OF AIR 2 A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED THE COMPRESSOR FRAME MUST BE LEVELLED A...

Страница 34: ...3 Specifications SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 33 Subject to EAR ECCN EAR99 and related export control restrictions 3 9 Identification water cooled 02250242 503 R02...

Страница 35: ...REE CIRCULATION OF AIR 2 A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED THE COMPRESSOR FRAME MUST BE LEVELLED...

Страница 36: ...fications SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 35 Subject to EAR ECCN EAR99 and related export control restrictions 3 10 Piping instrumentation air cooled SN55 SN75 02250218...

Страница 37: ...VALVE COMBO 1 22 STRAINER VTYPE 1 23 VALVE SOLENOID 2 24 VALVE PRESSURE REG 1 25 TANK SEPARATOR 1 26 FILTER PNEUMATIC 1 27 VALVE CHECK 1 28 VALVE BALL STNR COMBO 1 29 DRAIN 1 30 VENTILATOR 1 31 GAUGE...

Страница 38: ...ications SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 37 Subject to EAR ECCN EAR99 and related export control restrictions 3 11 Piping instrumentation water cooled SN55 SN75 02250218...

Страница 39: ...3 VALVE SOLENOID 3WNO 2 24 VALVE PRESSURE REG 1 25 TANK SEPARATOR 1 26 FILTER PNEUMATIC 1 27 VALVE CHECK 2 28 HEAT EXCHANGER 1 29 SWITCH PRESS 1 30 VALVE WATER REG 1 31 VALVE SOLENOID 2WNC 1 32 VALVE...

Страница 40: ...ications SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 39 Subject to EAR ECCN EAR99 and related export control restrictions 3 12 Piping instrumentation air cooled SN55S SN75S 02250243...

Страница 41: ...1 21 VALVE SOLENOID 3WNO 2 22 VALVE BLOWDOWN 1 23 REGULATOR 1 24 TANK SEPARATOR 1 25 FILTER PNEUMATIC 1 26 VALVE CHECK 2 27 VALVE BALL STNR COMBO 1 28 DRAIN ZERO LOSS 1 29 VALVE SPRIAL 1 Drawing note...

Страница 42: ...cations SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 41 Subject to EAR ECCN EAR99 and related export control restrictions 3 13 Piping instrumentation water cooled SN55S SN75S 0225024...

Страница 43: ...1 23 TANK SEPARATOR 1 24 FILTER PNEUMATIC 1 25 VALVE CHECK 2 26 VALVE THERMAL 1 27 SWITCH PRESS 1 28 VALVE WATER REGULATOR 1 29 VALVE SOLINOID 2WNC 1 30 VALVE BALL STRAINER COMBO 1 31 DRAIN ZERO LOSS...

Страница 44: ...ications SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 43 Subject to EAR ECCN EAR99 and related export control restrictions 3 14 Piping instrumentation air cooled SN55V SN75V 02250243...

Страница 45: ...OR WATER 1 19 ELEMENT SEPARATOR 1 20 VALVE DRAIN 1 21 VALVE SOLINOID 3WNO 1 22 TANK SEPARATOR 1 23 FILTER PNEUMATIC 1 24 VALVE CHECK 2 25 VALVE BALL STRAINER COMBO 1 26 DRAIN ZERO LOSS 1 27 VALVE THER...

Страница 46: ...cations SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 45 Subject to EAR ECCN EAR99 and related export control restrictions 3 15 Piping instrumentation water cooled SN55V SN75V 0225024...

Страница 47: ...ALVE DRAIN 1 21 VALVE SOLENOID 3WNO 1 22 TANK SEPARATOR 1 23 FILTER PNEUMATIC 1 24 VALVE CHECK 2 25 VALVE THERMAL 1 26 SWITCH PRESS 1 27 VALVE WATER REG 1 28 VALVE SOLENOID 2WNC 1 29 VALVE BALL STRAIN...

Страница 48: ...3 Specifications SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 47 Subject to EAR ECCN EAR99 and related export control restrictions 3 16 Wiring diagram wye delta 02250242 364 R04 sh1...

Страница 49: ...SN55 SN55S SN55V SN75 SN75S SN75V User Manual 3 Specifications 02250247 571 R04 Subject to EAR ECCN EAR99 and related export control restrictions 48 3 16 Wiring diagram wye delta 02250242 364 R04 sh2...

Страница 50: ...EE TRANSFORMER CONNECTION TABLE FOR PROPER VOLTAGE CONNECTION TRANSFORMER FUSING ON CLIPS LOCATED ON TRANSFORMER X1 XF INTERNALLY JUMPERED SEE TRANSFORMER FUSE CHART FOR SIZING 5 REFER TO SEQUENCING P...

Страница 51: ...SN55 SN55S SN55V SN75 SN75S SN75V User Manual 3 Specifications Notes 02250247 571 R04 Subject to EAR ECCN EAR99 and related export control restrictions 50...

Страница 52: ...cations SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 51 Subject to EAR ECCN EAR99 and related export control restrictions 3 17 Wiring diagram VSD air cooled parallel wye 02250243 116...

Страница 53: ...S SN55V SN75 SN75S SN75V User Manual 3 Specifications 02250247 571 R04 Subject to EAR ECCN EAR99 and related export control restrictions 52 3 17 Wiring diagram VSD air cooled parallel wye 02250243 116...

Страница 54: ...CTION TABLE FOR PROPER VOLTAGE CONNECTION TRANSFORMER FUSING ON CLIPS LOCATED ON TRANSFORMER X1 XF INTERNALLY JUMPERED SEE TRANSFORMER FUSE CHART FOR SIZING 5 REFER TO SEQUENCING PROTOCOL MANUAL 6 SEP...

Страница 55: ...equate space must be provided for the compressor and its components Air cooled compressors require a minimum of 4 feet 1 25 meters around the perimeter of the compressor The location should be free fr...

Страница 56: ...utilizing this heat If ductwork is added the high static fan option is required Do not install a water cooled or an air cooled after cooled compressor where it will be exposed to tempera tures less t...

Страница 57: ...levels of dissolved oxygen and low pH levels assist in the creation of corrosive scale A thin coating of lime scale is often beneficial in helping to prevent corrosion from form ing 4 2 5 3 Biologica...

Страница 58: ...extreme such that direct rain or snow may fall on the unit it should be in a fully enclosed room or building If installed under a shelter air cooled machines must be positioned in a way that prevents...

Страница 59: ...era ture below the dew point For most ambient conditions considerable water vapor is condensed To remove the condensation each compressor with built in aftercooler is supplied with a combination conde...

Страница 60: ...e electrical feed point is critical as voltage drops may impair the performance of the com pressor Cable sizes may vary considerably so the mains terminals will accept up to 50 mm2 1 awg 37 4 Sk 50 60...

Страница 61: ...the STS monitor to display the P1 separator sump tank pressure Pull out the EMERGENCY STOP button and press once quickly and in succession the Start and Stop buttons This action will bump start the mo...

Страница 62: ...4 Installation SN55 SN55S SN55V SN75 SN75S SN75V User Manual Notes 02250247 571 R04 61 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 63: ...ontroller 5 1 Controller layout Figure 5 1 Controller layout and button functions Key Description Function 1 Start button Push to start the compressor Can also be used to reset maintenance and warning...

Страница 64: ...ght may blink rapidly if a machine start is immi nent Maintenance or Warning Indicator Amber Lights when recommended maintenance or service warning is issued In most cases the machine will continue to...

Страница 65: ...and run times starts and cycles and message related to the current status state and mode The gauge area below shows discharge tem perature discharge pressure and sump pres sure as analog gauges You ca...

Страница 66: ...maintenance information Login in as an administrator And perform other administrative functions To view the complete menu hierarchy see Section 5 5 on page 67 You can reach the main menu by pressing t...

Страница 67: ...nd Celsius C as the unit of measure for temperature Language The user can choose between English Spanish French Portuguese Russian and Chinese for the display language Note The display language change...

Страница 68: ...r SN55 SN55S SN55V SN75 SN75S SN75V User Manual 02250247 571 R04 67 Subject to EAR ECCN EAR99 and related export control restrictions 5 5 Menu hierarchy Figure 5 5 Sullair touch screen controller menu...

Страница 69: ...ts of an antenna installed on the outside of the compressor s enclosure and an M70 modem installed inside the compressor s control cabinet The LED lights on the modem indicate the current status of th...

Страница 70: ...5 Controller SN55 SN55S SN55V SN75 SN75S SN75V User Manual Notes 02250247 571 R04 69 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 71: ...warmed up it is recommended that a general check on the overall compressor be made to assure that the compressor is running properly 6 3 Maintenance after initial 50 hours of operation After the init...

Страница 72: ...Refer to Figure 6 2 Air filter maintenance should be per formed when the maintenance gauge shows red with the compressor running full load or once a year whichever comes first If the filter needs to...

Страница 73: ...of the cover plate and the separator sump tank flange Do not let any scraps fall into the separator sump tank 6 Inspect the separator sump tank for rust dirt etc 7 Insert a new separator element into...

Страница 74: ...assembly and replace with new assembly 4 Inspect and clean the orifice inside the sight glass blocks The orifice must be removed with an allen wrench 5 Coat lubricate the O rings with silicone grease...

Страница 75: ...ng the coupling element 3 Unwrap the coupling element from the coupling jaws 4 Install the new element by wrapping it around the jaws engaging the cogs on the element into the jaws 5 Reinstall the out...

Страница 76: ...ure to 85 F 29 4 C or less Water cooled only Cooling water flow insufficient Check water lines and valves water cooled only Cooler plugged Clean tubes If plugging persists install water conditioner wa...

Страница 77: ...el too high Drain and change Check that the compressor temperature has not dropped below 170 F 76 7 C Pressure relief valve opens repeatedly Defective pressure relief valve Replace Plugged separator C...

Страница 78: ...6 Maintenance SN55 SN55S SN55V SN75 SN75S SN75V User Manual Notes 02250247 571 R04 77 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 79: ...Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 80: ...ons are subject to change without prior notice Subject to EAR ECCN EAR99 and related export control restrictions Sullair LLC 1 Sullair Way Michigan City IN 46360 USA www sullair com 1 800 SULLAIR USA...

Отзывы: