background image

Section 7

ILLUSTRATIONS AND PARTS LIST

57

7.11 ELECTRO---PNEUMATIC CONTROL SYSTEM

key

part

number

description

number

quantity

1

frame, control box support

02250103---086

1

2

box, control

02250104---633

1

3

block, terminal and track

041493

9

4

panduit

047322

1

5

track, snap mounting

250024---522

1

6

control, temperature dual

250039---911

1

7

pin, socket for 120V plug---in relay

045497

1

8

relay, control 120V 10A 3PDT

045496

1

9

fuse, non 5

241957

1

10

fuseholder

041147

1

11

transducer, pressure

02250078---933

4

12

nipple, chase --- conduit 1/2”

847815---050

2

13

locknut, conduit 1/2”

847200---050

11

14

switch, vacuum 22” wc

02250078---249

1

15

switch, emergency stop

02250085---504

1

16

block, control --- normally closed

250027---125

1

17

light, power energized

250000---105

1

18

decal, power energized

249554---049

1

19

control, supervisor micro cntrlr

02250071---231

1

20

cord, grip

250023---496

3

21

bulkhead pipe 1/8”

841500---002

4

22

nipple, pipe 1/4” x close

822204---000

12

23

tee, pipe 1/4”

804415---010

5

24

elbow, pipe 90

_

x 1/4”

801515---010

2

25

connector, tube---m 1/4” x 1/4”

810204---025

9

26

filter, control line air 1/4”

(I)

02250112---032

2

27

elbow, tube---m 1/4” x 1/4”

810504---025

5

28

tubing, steel 1/4”

841015---004

62 ft.

29

angle, pressure switch

230452

1

30

switch, water pressure (w/c only)

043428

1

31

valve, solenoid 1/4” 3---way 115V

(II)

250038---668

1

32

tee, tube 1/4”

810904---025

1

33

valve, shuttle

408893

2

(Continued on page 59)

(I)

For maintenance on control air filter no. 02250112---032, order element/seal kit no. 02250112---031, and

float assembly/seal kit no. 02250115---960.

(II)

For maintenance on solenoid valve no. 250038---668, order repair kit no. 250038---673 (valve), and repair kit

no. 250031---738 (coil).

PLEASE NOTE: WHEN ORDERING PARTS, INDICATE SERIAL NUMBER OF COMPRESSOR

Содержание LS-25S-257KW

Страница 1: ...INDUSTRIAL ROTARY SCREW LS 25S 257KW EQUIPMENT NO OPERATOR S MANUAL AND Part Number 02250127 759 eSullair Corporation AIR COMPRESSOR SUPERVISOR II PARTS LIST 1 MC QB001 0 MC QB001 2 MC QB001 ...

Страница 2: ...at Sullair s corporate headquarters in Michigan City Indiana Instruction includes discussion of the function and installation of Sullair service parts troubleshooting of the most common problems and actual equipment operation The seminars are recommended for maintenance and service personnel For detailed course outlines schedule and cost information contact Sullair Corporate Training Department 1 ...

Страница 3: ...ND LUBRICATION SYSTEM FUNCTIONAL DESCRIPTION 7 2 5 COMPRESSOR DISCHARGE SYSTEM FUNCTIONAL DESCRIPTION 8 2 6 CONTROL SYSTEM FUNCTIONAL DESCRIPTION 11 2 7 AIR INLET SYSTEM FUNCTIONAL DESCRIPTION 11 2 8 SUPERVISOR II PANEL BASIC INSTRUCTION 11 2 9 KEYPAD 13 2 10 STATUS DISPLAYS 14 2 11 LAMP INDICATORS Section 3 SPECIFICATIONS 15 3 1A IDENTIFICATION LS25S 16 3 1B LS25S COOLER PACK 17 3 2 LUBRICATION G...

Страница 4: ...LY OPERATION 29 6 3 MAINTENANCE AFTER INITIAL 50 HOURS OF OPERATION 29 6 4 MAINTENANCE EVER 1000 HOURS 29 6 5 FLUID CHANGE 29 6 6 SEPARATOR MAINTENANCE 29 6 7 PARTS REPLACEMENT AND ADJUSTMENT PROCEDURES 29 MAIN FILTER MAINTENANCE 30 AIR FILTER MAINTENANCE 31 SEPARATOR ELEMENTS REPLACEMENT 32 DIFFERENTIAL PRESSURE REGULATOR ADJUSTMENT 32 PRESSURE REGULATOR MAINTENANCE 32 DRIVE COUPLING INSTALLATION...

Страница 5: ...4 7 6 FLUID COOLING SYSTEM AIR COOLED REMOTE COOLER 46 7 7 FLUID COOLING SYSTEM AIR COOLED REMOTE LOW NOISE 48 7 8 COMPRESSOR DISCHARGE SYSTEM 52 7 9 SULLICON CONTROL 54 7 10 COMPRESSOR ACTUATOR 56 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM 60 7 12 ENCLOSURE 64 7 13 UNIT TUBING 66 7 14 DECAL GROUP 72 7 15 DECAL LOCATIONS 74 7 16 PIPING AND INSTRUMENTATION 76 7 17 WIRING DIAGRAM ...

Страница 6: ...hut off throttle valve either at the compressor or at any other point along the air line when an air hose exceeding 1 2 13mm inside diameter is to be connected to the shut off throttle valve to reduce pressure in case of hose failure per all applicable Federal State and Local codes standards and regulations B When the hose is to be used to supply a manifold install an additional appropriate flow l...

Страница 7: ... rags trash leaves litter or other com bustibles out of and away from the compressor J DO NOT operate the compressor without proper flow of cooling air or water or with inadequate flow of lubricant or with degraded lubricant K DO NOT attempt to operate the compressor in any classification of hazardous environment unless the compressor has been specially designed and manufactured for that duty 1 5 ...

Страница 8: ...ded with open electrical enclosures If necessary to do so then disconnect lock out and tag all power at source so others will not inadvertently restore power E Disconnect lock out and tag all power at source prior to attempting repairs or adjustments to rotating machinery and prior to handling any ungrounded conductors F Dry test all shutdown circuits prior to starting the compressor after install...

Страница 9: ...rge enough to hold a person and if it is necessary to enter it to per form service adjustments inform other personnel before doing so or else secure and tag the access door in the open position to avoid the possibility of others closing and possibly latching the door with personnel inside B Make sure all personnel are out of compressor before closing and latching enclosure doors ...

Страница 10: ...arly shown The complete package includes compressor electric motor compressor inlet system compressor discharge system compressor cooling and lu brication system capacity control system and Supervisor II Control System all mounted on a structural steel frame On air cooled models the cooling package is re mote mounted and shipped as a separate unit The separate motor driven fan cooling package forc...

Страница 11: ...Section 2 DESCRIPTION 6 Figure 2 2 Compressor Piping and Instrument Diagram ...

Страница 12: ...p valve is held open by air pressure from the compressor unit allowing a free flow of fluid from the receiver sump back to the compressor unit On shutdown the compressor unit pressure is re duced causing the fluid stop valve to close and iso late the compressor unit from the cooling system 2 5 COMPRESSOR DISCHARGE SYSTEM FUNC TIONAL DESCRIPTION Refer to Figure 2 2 The compressor unit dis charges t...

Страница 13: ...valve as well as the inlet butterfly valve remain in the full load po sition as long as the compressor is running at 100 psig 6 9 bar or below MODULATION 100 to 110 PSIG 6 9 TO 7 6 BAR As air demand drops below the rated capacity of the compressor the line pressure will rise above 100 psig 6 9 bar As a result the differential pres sure regulator for the spiral valve gradually opens applying air pr...

Страница 14: ...Section 2 DESCRIPTION 9 Figure 2 3A Control System Diagram Start Full Load ...

Страница 15: ...Section 2 DESCRIPTION 10 Figure 2 3B Control System Diagram Modulation Unload ...

Страница 16: ...alve The vacuum switch located on the compressor Supervisor Control System indicates the condition of the air filter When the message AIR FILTER MAINT RQD is displayed maintenance is re quired The butterfly type air inlet valve directly controls the amount of air intake to the compressor in re sponse to the operation of the Sullicon Control see Section 2 6 Control System Functional Descrip tion 2 ...

Страница 17: ...machine is running S Display Used to display pressures temperatures and other status information See section on STATUS DISPLAYS DSP S Logo Used for various functions de scribed in later sections S Program Used to enter the parameter change mode where control parameters may be displayed and changed See PA RAMETER SETUP PRG S Up arrow Used in status displays to change displays and in parameter setup...

Страница 18: ...hey will alternately be shown with the default display The machine status will be displayed for 2 seconds then the alarms for 2 seconds each For example T1 HI 110 180 To view other status press the DISPLY key All tem peratures and pressures may be displayed as well as other status information To scroll through the displays press the up arrow or down arrow keys Up arrow moves to the next display do...

Страница 19: ...e notes replacement of separator is needed ΔP2 Oil filter differential pressure ΔP3 Oil differential pressure T1 Dry side discharge temperature If lit steady signifies that T1 is being displayed if flashing de notes the presence of an alarm T2 Discharge temperature If lit steady signifies that T2 is being displayed if flashing denotes the presence of an alarm T3 Oil temperature If lit steady signi...

Страница 20: ...Section 3 SPECIFICATIONS 15 3 1A Identification LS25S 02250122 158R2 ...

Страница 21: ...Section 3 SPECIFICATIONS 16 3 1B Identification LS25S Cooler Pack 02250122 154R1 ...

Страница 22: ...corrosive gases or strong oxidiz ing gases are present in the air WARNING Mixing of other lubricants within the compressor unit will void all warranties WARNING The Plastic Pipe Institute recommends against the use of thermoplastic pipe to transport compressed air or other compressed gases in exposed above ground locations e g in exposed plant piping I Sullube should not be used with PVC piping sy...

Страница 23: ...18 NOTES ...

Страница 24: ...drains throughout the system WARNING The Plastic Pipe Institute recommends against the use of thermoplastic pipe to transport compressed air or other compressed gases in exposed above ground locations e g in exposed plant piping I Sullube should not be used with PVC piping sys tems It may affect the bond at cemented joints Cer tain other plastic materials may also be affected I Plastic Pipe Instit...

Страница 25: ...led the coolant level should fill 1 2 of the sight glass when the com pressor is shutdown 4 7 ELECTRICAL PREPARATION Interior electrical wiring is performed at the factory Required customer wiring is minimal but should be done by a qualified electrician in compliance with any applicable regional or local electrical code concerning isolation switches fuse disconnects etc Sullair provides a wiring d...

Страница 26: ...k the direction of motor rotation Pull out the EMERGENCY STOP button and press once quickly and in succession the START I and STOP O pads This action will bump start the mo tor for a very short time When looking at the motor rear end the driveline should be rotating in the di rection indicated by the Direction of Rotation de cal located on the top of the compressor motor adapter piece If the rever...

Страница 27: ...22 NOTES ...

Страница 28: ...d to and around the cooler De signed to maintain a minimum operating temperature of 170_F 77_C used for fast warm up on start up MINIMUM PRESSURE CHECK VALVE Maintains minimum of 50 psig 3 4 bar in the com pressor sump Valve piston restricts receiver air dis charge from receiver sump when pressure falls to 40 psig 2 8 bar Prevents line pressure backflow into the sump during unload conditions and a...

Страница 29: ...er S Unload pressure The pressure where the machine is unloaded For example if this parameter is set to 110 PSI 7 6 bar the machine will unload when the line pres sure is above 110 PSI 7 6 bar UNLOAD 100 PSI S Load differential The pressure differ ential below the unload pressure where the machine is loaded For example if the un load pressure is set to 110 PSI 7 6 bar and the load differential is ...

Страница 30: ...ressure Used only for sequencing see Sequencing Proto col Manual for details LOWEST 90 PSI S Recovery Time Used only for sequenc ing see Sequencing Protocol Manual for details RECOVER 10 SEC SRotate Time Used only for sequencing see Sequencing Protocol Manual for de tails ROTATE 50 S Machine Capacity Used only for se quencing see Sequencing Protocol Manual for details CAPACITY 100 S Sequence Hours...

Страница 31: ... If this time is set to a value the machine will go into standby after power up When the line pressure drops below the load setpoint the restart timer will start timing When the timer expires the machine will start SEQUENCING MODES The following is a brief description of sequencing modes for details see the Supervisor II Sequenc ing Protocol Manual P N 02250057 696 S DISABLED Responds to status an...

Страница 32: ...iping 6 Slowly close the shut off valve and check that the maximum pressure P2 and pressure differ ential P2 are correctly programmed 7 Observe the operating temperature If the oper ating temperature exceeds 212_F 100_C the cooling system or installation environment should be checked 8 Observe return line sight glasses and mainte nance indicators 9 Open shut off valve to service line 10 Reinspect ...

Страница 33: ...28 NOTES ...

Страница 34: ...ccumu lated during compressor assembly Perform the fol lowing maintenance operations to prevent unnec essary problems 1 Clean the return line strainers 2 Clean the return line orifices 3 Change the fluid filter elements 4 Clean the control line filters 6 4 MAINTENANCE EVERY 1000 HOURS After 1000 hours of operation it will be necessary to perform the following 1 Clean the return line strainers 2 Lu...

Страница 35: ...ENANCE Refer to Figure 6 2 Air filter maintenance should be performed when the air filter maintenance mes sage is displayed The air filter is equipped with a primary element and a secondary element As pre viously stated the Supervisor will alert you as to when the primary element maintenance is neces sary When removing the primary element always check the secondary element for visible dirt grease ...

Страница 36: ... for separator element replace ment 1 Relieve all pressure from the separator and all compressor lines 2 Disconnect all piping connected to the separator cover return lines service lines etc to allow re moval 3 Loosen and remove the twelve 12 3 4 x 3 hex head capscrews from the cover plate 4 Lift the cover plate from the separator 5 Remove the primary and secondary separator elements 6 Scrape the ...

Страница 37: ...nd seat gasket 6 Remove and discard the seat ring 7 The next step is to reassemble the regulator us ing the new parts provided in your repair kit 8 Reassemble the diaphragm pressure plate gasket seat disc and seat disc gasket and tighten the nut All of these parts with the excep tion of the pressure plate are provided in the re pair kit 9 Replace the seat ring with the new seat ring pro vided 10 R...

Страница 38: ... on one shaft and rotate the hub 360_ while taking readings on the flange face as shown DO NOT ex ceed installation ANGULAR limit specified in Table 1 When using a dial indicator the best results are achieved by rotating both driver and driven shafts together CAUTION Dial indicator face readings should not be used on journal bearing equipment due to the liberal end float inherent in such a design ...

Страница 39: ...ashers through hub flange holes and engage tapped holes in each adaptor Tighten adapter bolts to recommended torque per Table 1 After torquing all adapter bolts recheck the alignment STEP 4 INSTALLATION OF SHRINK DISC Refer to Figures 6 6 and 6 7 Shrink discs are supplied ready for installation Therefore they should not be disassembled prior to initial installa tion INSTALLATION SEQUENCE 1 Remove ...

Страница 40: ...of damage connections are sat isfactory 4 If boot or insulating material show distress as mentioned above then investigate to determine the source of thermal damage and repair the connection as necessary 5 Replace the damaged boot s with new boot s as required or retape connections per National State or Local codes 6 Replace the conduit cover prior to reconnecting the power source WARNING Electric...

Страница 41: ...ssure is reached Repair if defective Open or shorted P1 P2 P3 or P4 sender message replace sender indicated Cooling air flow restricted clean cooler and check for proper ventilation Ambient temperature is too high provide sufficient ventilation Low fluid level add fluid Clogged filter change the fluid filter element as indicated by Supervisor control Thermal valve not functioning properly replace ...

Страница 42: ...kit for thermal valve 041299 001084 1 element for separator with gaskets 250034 123 primary 250034 124 1 element for separator with gaskets 250034 129 secondary 250034 130 1 repair kit for regulator valve 406929 041742 1 repair kit for blowdown valve 409783 001667 1 repair kit for Sullicon Control 011682 003 250020 353 1 repair kit for control line filter 02250112 032 02250112 031 element seal 1 0...

Страница 43: ...Section 7 ILLUSTRATIONS AND PARTS LIST 38 7 3 MOTOR COMPRESSOR FRAME AND PARTS 02250126 798R0 ...

Страница 44: ...r hex gr5 1 2 13 x 1 1 4 829108 125 4 16 washer spr lock reg pltd 3 4 837812 188 4 17 capscr hex gr5 3 4 10 x 3 829112 300 4 18 washer spr lock reg pltd 7 8 837814 219 4 19 nut hex pltd 7 8 9 825214 776 4 20 capscr hex gr5 7 8 9 x 3 1 2 829114 350 4 21 sign warning sever fan port 049965 1 22 decal fork lifting 241814 2 I There is an exchange program whereby a remanufactured compressor unit can be ...

Страница 45: ...Section 7 ILLUSTRATIONS AND PARTS LIST 40 7 4 COMPRESSOR AIR INTAKE SYSTEM 02250126 797R0 ...

Страница 46: ... 8 16 825206 337 4 15 connector tube m 1 4 x 1 8 813604 125 1 16 rod link 5 16 24 x 9 1 2 021287 1 17 lever inl vlv 3 4 shft adj 250019 036 1 18 bracket sullicon ctl 255 250007 789 1 19 support 18 hd air filter 250007 788 1 20 filter 18 dia air I 250006 718 1 21 adapter inlet 10 to 8 250003 378 1 22 rod end spherical rh 5 16 040136 1 23 gasket 06 x 10 5id x 13 25od 041079 2 24 valve butterfly 10 0...

Страница 47: ...Section 7 ILLUSTRATIONS AND PARTS LIST 42 7 5 FLUID COOLING PIPING SYSTEM AIR COOLED REMOTE COOLER 02250126 800R0 ...

Страница 48: ... 895 1 9 flange thrd red 3 x 9 819548 090 1 10 flange thrd 4 150 rf 819315 064 1 11 gasket asa flange 150 3 240621 008 1 12 gasket asa flange 150 4 240621 010 1 13 washer spr lock reg pltd 5 8 837810 156 12 14 capscr hex gr5 5 8 11 x 3 829110 300 12 15 nut hex pltd 5 8 11 825210 559 12 16 u bolt 1 2 x 3 pipe pltd 868308 300 2 17 washer pl b reg pltd 1 2 838208 112 4 18 nut hex pltd 1 2 13 825208 4...

Страница 49: ...Section 7 ILLUSTRATIONS AND PARTS LIST 44 7 6 FLUID COOLING SYSTEM AIR COOLED REMOTE COOLER 02250126 801R0 ...

Страница 50: ...tor tube m 2 x 2 810232 200 10 18 connector tube m 1 2 x 1 2 810208 050 1 19 bracket dual tube support 250010 896 1 20 bracket sing tube support 250010 895 1 21 bracket oil connection 2 npt 250007 794 1 22 adapter port 2 npt 250007 220 2 23 filter fluid I 250007 219 1 24 switch temp n o 115f 043239 1 25 valve thermal 170 2 npt II 041299 1 26 valve check swing 2 npt 040671 1 27 tube thermal vlv byp...

Страница 51: ...Section 7 ILLUSTRATIONS AND PARTS LIST 46 7 7 FLUID COOLING SYSTEM AIR COOLED REMOTE LOW NOISE 02250127 327R0 ...

Страница 52: ...er 049104 2 19 plug pipe 2 3000 stl plt 866900 080 2 20 gasket 4 125 flg full face 242437 010 1 21 capscr hex gr5 3 8 16 x 1 829106 100 92 22 washer pl b reg pltd 3 8 838206 071 12 23 washer spr lock reg pltd 3 8 837806 094 92 24 washer spr lock reg pltd 1 2 837808 125 10 25 washer pl b reg pltd 1 2 838208 112 10 26 capscr hex gr8 1 2 13 x 2 827908 200 10 27 nut hex pltd 1 2 13 825208 448 10 28 wa...

Страница 53: ...Section 7 ILLUSTRATIONS AND PARTS LIST 48 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...

Страница 54: ...ltd 3 4 838212 112 4 17 washer spr lock reg pltd 3 4 837812 188 4 18 washer spr lock reg pltd 5 8 837810 156 8 19 capscr hex gr5 3 4 10 x 2 829112 200 4 20 capscr hex gr5 5 8 11 x 3 829110 300 8 21 nut hex pltd 5 8 11 825210 559 8 22 nipple pipe xs galv 1 4 x cl 823204 000 5 23 nip xs 1 1 4 x cls 822220 000 2 24 nipple pipe xs 1 x cl 822216 000 2 25 elbow tube union 5 16 811205 031 1 26 elbow tube...

Страница 55: ...Section 7 ILLUSTRATIONS AND PARTS LIST 50 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...

Страница 56: ...l sight 1 1 2 040279 1 51 plug o ring boss sae 1 1 4 040029 1 52 orifice 062 x 25m x 25m nptf 027443 1 53 valve ball 3 4 npt apollo 02250117 792 1 54 joint expansion disch tnk ls25s ac wc 02250116 346 1 55 tank oil separator 30 dia 150 fl 02250114 256 1 56 fitting flex 5 16 x 1 4mpt 020501 1 57 connector flex 1 4t x 1 4p 020169 1 58 filler adapter 020044 1 59 sign warning hot surfaces 407408 3 I F...

Страница 57: ...Section 7 ILLUSTRATIONS AND PARTS LIST 52 7 9 SULLICON CONTROL 4 5 7 9 10 11 12 15 19 16 21 20 23 25 6 8 14 13 17 18 29 27 22 5 28 5 7 15 24 26 30 33 5 1 3 2 ...

Страница 58: ... 3 7 8 250006 526 1 14 cover control 021654 1 15 pin yoke 1 4 with cotter pin 040065 1 16 yoke rod end 1 4 28 040138 1 17 plunger 020094 1 18 seal cup 042538 1 19 screw hex unmachined 5 16 24 x 2 831105 200 1 20 nut hex jam unfinished 5 16 24 right hand 824605 195 1 21 nut hex unfinished 5 16 18 824205 273 1 22 washer springlock regular 5 16 837506 200 1 23 screw machine shoulder 3 8 x 2 830506 20...

Страница 59: ...Section 7 ILLUSTRATIONS AND PARTS LIST 54 7 10 COMPRESSOR ACTUATOR ...

Страница 60: ...4 20 x 1 2 828204 050 4 15 cover adapter 250021 510 1 16 washer regular 18 838201 045 6 17 screw machine rod 8 32 x 1 2 831601 050 6 18 mount air cylinder 250016 188 1 19 capscrew ferry head 5 16 18 x 1 1 4 828404 125 3 20 spring seal 2 1 4 250016 394 1 21 rack gear 250016 197 1 22 nut hex jam 3 8 16 824906 227 1 23 shaft air cylinder 250016 194 1 24 cylinder air I 250016 183 1 25 orifice 062 x 25...

Страница 61: ...Section 7 ILLUSTRATIONS AND PARTS LIST 56 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...

Страница 62: ...power energized 249554 049 1 19 control supervisor micro cntrlr 02250071 231 1 20 cord grip 250023 496 3 21 bulkhead pipe 1 8 841500 002 4 22 nipple pipe 1 4 x close 822204 000 12 23 tee pipe 1 4 804415 010 5 24 elbow pipe 90_ x 1 4 801515 010 2 25 connector tube m 1 4 x 1 4 810204 025 9 26 filter control line air 1 4 I 02250112 032 2 27 elbow tube m 1 4 x 1 4 810504 025 5 28 tubing steel 1 4 8410...

Страница 63: ...Section 7 ILLUSTRATIONS AND PARTS LIST 58 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...

Страница 64: ... 1 41 washer springlock regular 1 2 837508 125 1 42 washer pl b regular unfinished 1 2 837308 112 1 43 connector tube m 1 4 x 1 8 813604 125 1 44 tubing plastic 1 4 250024 745 16 ft 45 valve differential pressure regulator spiral valve V 408275 1 III For maintenance on solenoid valve no 250038 755 orer repair kit no 250038 676 valve and repair kit no 250038 730 coil IV For maintenance on different...

Страница 65: ...Section 7 ILLUSTRATIONS AND PARTS LIST 60 7 12 ENCLOSURE 02250126 791R0 ...

Страница 66: ...224 1 18 grille enclosure end 249651 2 19 guard fan 041765 1 20 channel bottom sill extension 25s rh 02250123 544 1 21 channel bottom sill extension 25s lh 02250123 547 1 22 handle canopy 042262 22 23 capscr hex gr5 1 4 20 x 1 2 829104 050 44 24 washer spr lock reg pltd 1 4 837804 062 44 25 nut hex pltd 1 4 20 825204 226 44 26 clamp wire 043194 16 27 screw hex ser washer 5 16 18 x 3 4 829705 075 1...

Страница 67: ...Section 7 ILLUSTRATIONS AND PARTS LIST 62 7 12 ENCLOSURE 02250126 791R0 ...

Страница 68: ... 2 829704 050 8 44 nut hex f pltd 1 4 20 825304 236 8 45 fan blower 20 30 deg 185q8f 02250107 474 1 46 motor 75hp 230 460 60 6p tepe 02250108 374 1 47 spacer fan support 227267 3 48 support fan motor 014613 1 49 capscr hex gr5 3 8 16 x 4 829106 400 3 50 washer pl b reg pltd 3 8 838206 071 6 51 nut hex locking 3 8 16 825506 198 3 52 washer pl b reg pltd 5 16 838205 071 8 53 nut hex locking 5 16 18 ...

Страница 69: ...Section 7 ILLUSTRATIONS AND PARTS LIST 64 7 13 UNIT TUBING ...

Страница 70: ...e M 1 x 1 810216 100 1 14 tube 250024 176 1 15 tube 250024 179 1 16 tube 250024 180 1 17 connector tube M 1 2 x 3 8 810208 038 1 18 elbow tube M 1 2 x 3 8 810508 038 4 19 plug pipe 1 4 807800 010 2 20 tube 250009 459 1 21 tee tube M 1 2 x 3 8 810808 038 1 22 orifice 3 8 m x 3 8 f x 094 250009 384 2 23 orifice 3 8 M x 3 8 F x 375 250009 460 1 24 tube 250009 456 1 25 tube 250009 455 1 26 tee tube un...

Страница 71: ...Section 7 ILLUSTRATIONS AND PARTS LIST 66 7 14 DECAL GROUP 1 2 3 4 5 6 7 8 9 10 11 12 ...

Страница 72: ...ground 02250075 046 1 9 sign danger electrocution 049850 1 10 sign power energized 249544 049 1 11 decal autostart 041065 1 12 decal fork lifting 241814 2 Continued on page 69 I Decal varies in accordance with machine voltage For machines with voltage other than 460 consult factory for decal part number II This decal is used in conjuction with standard fill Sullube fluid If your compressor contain...

Страница 73: ...Section 7 ILLUSTRATIONS AND PARTS LIST 68 7 14 DECAL GROUP OIL STOP VALVE P N 16742 410239 13 14 15 16 17 18 19 ...

Страница 74: ...t 049852 1 14 decal warning actuator 250029 836 1 15 decal danger high voltage 042218 1 16 decal warning mixing fluids 02250110 891 1 17 decal fluid sample 250022 675 1 18 decal fluid stop valve P N 016742 410239 1 19 decal Sullair logo 02250059 048 2 Continued on page 71 PLEASE NOTE WHEN ORDERING PARTS INDICATE SERIAL NUMBER OF COMPRESSOR ...

Страница 75: ...Section 7 ILLUSTRATIONS AND PARTS LIST 70 7 14 DECAL GROUP 24 22 23 26 20 21 25 ...

Страница 76: ...50057 624 1 21 decal actuator valve positioning 250029 784 1 22 sign warning food grade lube 250003 144 1 23 sign warning compressor fluid fill cap 049685 1 24 decal warning auto start 250017 903 1 25 sign warning hot surfaces 407408 3 26 decal LS 25S 02250061 361 1 PLEASE NOTE WHEN ORDERING PARTS INDICATE SERIAL NUMBER OF COMPRESSOR ...

Страница 77: ...Section 7 ILLUSTRATIONS AND PARTS LIST 72 7 15 DECAL LOCATIONS ...

Страница 78: ...1 361 1 15 decal autostart 041065 1 16 sign warning sever fan port III 049965 1 17 sign warning sever fan IV 049855 2 18 decal rotation III 250021 564 1 19 decal fork lifting IV 241814 2 20 decal actuator valve positioning V 250029 784 1 21 decal warning actuator V 250029 836 1 I Decal varies in accordance with machine voltage For machines with voltage other than 460 consult factory for decal part...

Страница 79: ...Section 7 ILLUSTRATIONS AND PARTS LIST 74 7 16 PIPING AND INSTRUMENTATION 02250122 160R8 ...

Страница 80: ...Section 7 ILLUSTRATIONS AND PARTS LIST 75 7 16 PIPING AND INSTRUMENTATION 02250122 159R2 ...

Страница 81: ...Section 7 ILLUSTRATIONS AND PARTS LIST 76 7 17 WIRING DIAGRAM 02250122 159R2 ...

Страница 82: ......

Страница 83: ...gan Boulevard Michigan City Indiana 46360 U S A Telephone 1 219 879 5451 Fax 219 874 1273 Fax 219 874 1835 Parts Fax 219 874 1288 Service SULLAIR ASIA LTD Sullair Road No 1 Chiwan Shekou Shenzhen Guangdong PRV PRC POST CODE 518068 Telephone 755 6851686 Fax 755 6853473 Zone Des Granges BP 82 42602 Montbrison Cedex France Telephone 33 477968470 Fax 33 477968499 ...

Отзывы: