Section 6
MAINTENANCE
36
6.9 TROUBLESHOOTING (CONTINUED)
SYMPTOM
PROBABLE CAUSE
REMEDY
COMPRESSOR WILL NOT START
Supervisor Panel Fuse is Blown
Replace fuse.
(CONT.)
Low Incoming Line Voltage
Check voltage. Should voltage check low,
consult power company.
Replace Supervisor controller if no display
or erratic display.
COMPRESSOR SHUTS DOWN
Loss of Control Voltage
Reset. If trouble persists, check that line
WITH AIR DEMAND PRESENT
pressure does not exceed maximum
operating pressure of the compressor
(specified on nameplate).
Low Incoming Voltage
Consult power company. The Sullair
Supervisor will provide indication of most
maintenance problems if control power has
not been lost. Shutdowns will occur upon a
faulty condition or a bad sender condition.
Excessive Operating Pressure
Check maximum P2 pressure setting.
“High Press P1” display; Max P1 pressure
may be set too low. Consult factory for
recalibration.
Defective solenoid valve; solenoid valve
should cause control lever to move to
unload stop when the pressure switch
contacts open. Repair if defective.
Defective blowdown valve; blowdown valve
should exhaust sump pressure to 40 to 50
psig (2.8 bar to 3.4 bar) when maximum
operating pressure is reached. Repair if
defective.
Open or shorted P1, P2, P3 or P4 sender
message; replace sender indicated.
Cooling air flow restricted; clean cooler and
check for proper ventilation.
Ambient temperature is too high; provide
sufficient ventilation.
Low fluid level; add fluid.
Clogged filter; change the fluid filter
element as indicated by Supervisor control.
Thermal valve not functioning properly;
replace element (air---cooled only).
Water flow regulating valve not functioning
properly; change (water---cooled only).
Open or shorted T1 or T2 sender; check for
a short or open circuit to probe and
correct wiring.
Low Fluid Pressure
(“Low Pressure P3” display)
Check fluid level.
PRESSURE RELIEF VALVE
Defective Pressure Relief Valve
Replace pressure relief valve.
OPENS REPEATEDLY
Check Separator Differential
(plugged)
Δ
P1
.
LIQUID WATER IN COMPRESSED
Water Vapor Condensation From Cooling Remove the water vapor from compressed air prior
AIR LINES
and Compression Occurs Naturally
to distribution through the air system. Check
operation of aftercooler and moisture separator.
Install a compressed air dryer sized for the flow and
dryness level required. (Note: Filters may also be
required to remove particulates, liquid oil aerosols
or for oil vapor removal. Change cartridges as
recommended by the filter manufacturer.) Check all
drain traps routinely to insure their proper
operation. Maintain them regularly.
Содержание LS-25S-257KW
Страница 11: ...Section 2 DESCRIPTION 6 Figure 2 2 Compressor Piping and Instrument Diagram ...
Страница 14: ...Section 2 DESCRIPTION 9 Figure 2 3A Control System Diagram Start Full Load ...
Страница 15: ...Section 2 DESCRIPTION 10 Figure 2 3B Control System Diagram Modulation Unload ...
Страница 20: ...Section 3 SPECIFICATIONS 15 3 1A Identification LS25S 02250122 158R2 ...
Страница 21: ...Section 3 SPECIFICATIONS 16 3 1B Identification LS25S Cooler Pack 02250122 154R1 ...
Страница 23: ...18 NOTES ...
Страница 27: ...22 NOTES ...
Страница 33: ...28 NOTES ...
Страница 43: ...Section 7 ILLUSTRATIONS AND PARTS LIST 38 7 3 MOTOR COMPRESSOR FRAME AND PARTS 02250126 798R0 ...
Страница 45: ...Section 7 ILLUSTRATIONS AND PARTS LIST 40 7 4 COMPRESSOR AIR INTAKE SYSTEM 02250126 797R0 ...
Страница 49: ...Section 7 ILLUSTRATIONS AND PARTS LIST 44 7 6 FLUID COOLING SYSTEM AIR COOLED REMOTE COOLER 02250126 801R0 ...
Страница 51: ...Section 7 ILLUSTRATIONS AND PARTS LIST 46 7 7 FLUID COOLING SYSTEM AIR COOLED REMOTE LOW NOISE 02250127 327R0 ...
Страница 53: ...Section 7 ILLUSTRATIONS AND PARTS LIST 48 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...
Страница 55: ...Section 7 ILLUSTRATIONS AND PARTS LIST 50 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...
Страница 59: ...Section 7 ILLUSTRATIONS AND PARTS LIST 54 7 10 COMPRESSOR ACTUATOR ...
Страница 61: ...Section 7 ILLUSTRATIONS AND PARTS LIST 56 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...
Страница 63: ...Section 7 ILLUSTRATIONS AND PARTS LIST 58 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...
Страница 65: ...Section 7 ILLUSTRATIONS AND PARTS LIST 60 7 12 ENCLOSURE 02250126 791R0 ...
Страница 67: ...Section 7 ILLUSTRATIONS AND PARTS LIST 62 7 12 ENCLOSURE 02250126 791R0 ...
Страница 69: ...Section 7 ILLUSTRATIONS AND PARTS LIST 64 7 13 UNIT TUBING ...
Страница 71: ...Section 7 ILLUSTRATIONS AND PARTS LIST 66 7 14 DECAL GROUP 1 2 3 4 5 6 7 8 9 10 11 12 ...
Страница 75: ...Section 7 ILLUSTRATIONS AND PARTS LIST 70 7 14 DECAL GROUP 24 22 23 26 20 21 25 ...
Страница 77: ...Section 7 ILLUSTRATIONS AND PARTS LIST 72 7 15 DECAL LOCATIONS ...
Страница 79: ...Section 7 ILLUSTRATIONS AND PARTS LIST 74 7 16 PIPING AND INSTRUMENTATION 02250122 160R8 ...
Страница 80: ...Section 7 ILLUSTRATIONS AND PARTS LIST 75 7 16 PIPING AND INSTRUMENTATION 02250122 159R2 ...
Страница 81: ...Section 7 ILLUSTRATIONS AND PARTS LIST 76 7 17 WIRING DIAGRAM 02250122 159R2 ...
Страница 82: ......