Section 5
OPERATION
23
5.1 GENERAL
While Sullair has built into this compressor a com-
prehensive array of controls and indicators to as-
sure you that it is operating properly, you will want
to recognize and interpret the reading which will
call for service or indicate the beginning of a mal-
function. Before starting your Sullair compressor,
read this section thoroughly and familiarize your-
self with the controls and indicators --- their pur-
pose, location and use.
5.2 PURPOSE OF CONTROLS
CONTROL OR INDICATOR
PURPOSE
FLUID LEVEL SIGHT GLASS
Monitors fluid level in the sump. Proper level should fill
the sight glass. Check the level when the compressor
is shut down.
DO NOT OVERFILL
.
SEPARATOR RETURN LINE SIGHT GLASS
Used to indicate fluid flow in the return line. When the
compressor is running at full load, fluid flow should be
visible in this sight glass. There may be little or no flow
when the compressor is running unloaded, but a slug-
gish flow at full load indicates a need to clean the return
line strainer.
FLUID STOP VALVE
Cuts off flow of fluid to compressor unit at compressor
shutdown and allows flow of fluid to the unit on start---
up.
DISCHARGE CHECK VALVE
Cuts off the reverse flow of air/fluid mixture through
compressor discharge system at compressor shut-
down.
THERMAL VALVE
Regulates flow of fluid to and around the cooler. De-
signed to maintain a minimum operating temperature
of 170
_
F (77
_
C); used for fast warm---up on start---up.
MINIMUM PRESSURE/CHECK VALVE
Maintains minimum of 50 psig (3.4 bar) in the com-
pressor sump. Valve piston restricts receiver air dis-
charge from receiver/sump when pressure falls to 40
psig (2.8 bar). Prevents line pressure backflow into
the sump during unload conditions and after shut-
down.
PRESSURE RELIEF VALVE
Opens sump pressure to the atmosphere should
pressure inside the sump become too high (150 psig
[10.3 bar]). Operation of this valve indicates that the
high pressure switch is either faulty or out of adjust-
ment.
SULLICON CONTROL
Regulates the amount of air allowed to enter the air in-
let valve. This regulation is determined by the amount
of air being used at the service line.
PRESSURE REGULATOR --- SULLICON
Opens a pressure line between the sump and Sul-
licon Control allowing the Sullicon Control to regulate
air delivery according to the air demand.
PRESSURE REGULATOR--- SPIRAL VALVE
Opens a pressure line between the service line and
the spiral valve actuator allowing the spiral valve to
regulate air delivery according to air demand.
SOLENOID VALVE #1
Bypasses the pressure regulator valve causing the
Sullicon Control to close the inlet valve when the
compressor reaches maximum operating pressure.
SOLENOID VALVE #2 (spiral valve control)
Opens when the compressor starts; closes when the
compressor is shut off. This prevents any air system
loss when the compressor is shut off.
Содержание LS-25S-257KW
Страница 11: ...Section 2 DESCRIPTION 6 Figure 2 2 Compressor Piping and Instrument Diagram ...
Страница 14: ...Section 2 DESCRIPTION 9 Figure 2 3A Control System Diagram Start Full Load ...
Страница 15: ...Section 2 DESCRIPTION 10 Figure 2 3B Control System Diagram Modulation Unload ...
Страница 20: ...Section 3 SPECIFICATIONS 15 3 1A Identification LS25S 02250122 158R2 ...
Страница 21: ...Section 3 SPECIFICATIONS 16 3 1B Identification LS25S Cooler Pack 02250122 154R1 ...
Страница 23: ...18 NOTES ...
Страница 27: ...22 NOTES ...
Страница 33: ...28 NOTES ...
Страница 43: ...Section 7 ILLUSTRATIONS AND PARTS LIST 38 7 3 MOTOR COMPRESSOR FRAME AND PARTS 02250126 798R0 ...
Страница 45: ...Section 7 ILLUSTRATIONS AND PARTS LIST 40 7 4 COMPRESSOR AIR INTAKE SYSTEM 02250126 797R0 ...
Страница 49: ...Section 7 ILLUSTRATIONS AND PARTS LIST 44 7 6 FLUID COOLING SYSTEM AIR COOLED REMOTE COOLER 02250126 801R0 ...
Страница 51: ...Section 7 ILLUSTRATIONS AND PARTS LIST 46 7 7 FLUID COOLING SYSTEM AIR COOLED REMOTE LOW NOISE 02250127 327R0 ...
Страница 53: ...Section 7 ILLUSTRATIONS AND PARTS LIST 48 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...
Страница 55: ...Section 7 ILLUSTRATIONS AND PARTS LIST 50 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...
Страница 59: ...Section 7 ILLUSTRATIONS AND PARTS LIST 54 7 10 COMPRESSOR ACTUATOR ...
Страница 61: ...Section 7 ILLUSTRATIONS AND PARTS LIST 56 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...
Страница 63: ...Section 7 ILLUSTRATIONS AND PARTS LIST 58 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...
Страница 65: ...Section 7 ILLUSTRATIONS AND PARTS LIST 60 7 12 ENCLOSURE 02250126 791R0 ...
Страница 67: ...Section 7 ILLUSTRATIONS AND PARTS LIST 62 7 12 ENCLOSURE 02250126 791R0 ...
Страница 69: ...Section 7 ILLUSTRATIONS AND PARTS LIST 64 7 13 UNIT TUBING ...
Страница 71: ...Section 7 ILLUSTRATIONS AND PARTS LIST 66 7 14 DECAL GROUP 1 2 3 4 5 6 7 8 9 10 11 12 ...
Страница 75: ...Section 7 ILLUSTRATIONS AND PARTS LIST 70 7 14 DECAL GROUP 24 22 23 26 20 21 25 ...
Страница 77: ...Section 7 ILLUSTRATIONS AND PARTS LIST 72 7 15 DECAL LOCATIONS ...
Страница 79: ...Section 7 ILLUSTRATIONS AND PARTS LIST 74 7 16 PIPING AND INSTRUMENTATION 02250122 160R8 ...
Страница 80: ...Section 7 ILLUSTRATIONS AND PARTS LIST 75 7 16 PIPING AND INSTRUMENTATION 02250122 159R2 ...
Страница 81: ...Section 7 ILLUSTRATIONS AND PARTS LIST 76 7 17 WIRING DIAGRAM 02250122 159R2 ...
Страница 82: ......