background image

AIR CARE SEMINAR TRAINING

Sullair Air Care Seminars are courses that provide hands-on instruction for the proper operation, maintenance,
and servicing of Sullair products. Individual seminars on Industrial compressors and compressor electrical
systems are offered at regular intervals throughout the year at Sullair’s corporate headquarters training facility
located at Michigan City, Indiana.

Instruction includes training on the function and installation of Sullair service parts, troubleshooting common
faults and malfunctions, and actual equipment operation. These seminars are recommended for maintenance,
contractor maintenance, and service personnel.

For detailed course outlines, schedule, and cost information contact:

S

ULLAIR

 C

USTOMER

 C

ARE

 T

RAINING

 D

EPARTMENT

1-888-SULLAIR or

219-879-5451 (ext. 5623)

www.sullair.com

- Or Write -

Sullair Corporation

3700 E. Michigan Blvd.

Michigan City, IN 46360

Attn: Service Training Department.

Содержание 02250165-411 R01

Страница 1: ...s warranty WARRANTY NOTICE PART NUMBER KEEP FOR FUTURE REFERENCE USER MANUAL SULLAIR CORPORATION The information in this manual is current as of its publication date and applies to compressor serial n...

Страница 2: ...cated at Michigan City Indiana Instruction includes training on the function and installation of Sullair service parts troubleshooting common faults and malfunctions and actual equipment operation The...

Страница 3: ...2 STARTUP PROCEDURES 11 2 1 INTRODUCTION 11 2 2 WS CONTROLLER PANEL LAYOUT 12 2 3 WS START UP PROCEDURES 13 2 4 SHUTDOWN PROCEDURE SECTION 3 ADJUSTMENTS 15 3 1 INTRODUCTION 15 3 2 COMPRESSOR ADJUSTMEN...

Страница 4: ...UBLESHOOTING GUIDE 31 5 3 WS CONTROLLER FAULTS AND WARNINGS 31 5 4 MACHINE BEHAVIOR AFTER A POWER INTERRUPTION 31 5 5 INTERNAL BATTERY 33 5 6 REPLACEMENT CONNECTOR PLUGS SECTION 6 VARIABLE SPEED DRIVE...

Страница 5: ...rein are applicable to most compressors and the concepts behind these statements are generally applicable to all compressors 1 2 PERSONAL PROTECTIVE EQUIPMENT A Prior to installing or operating the co...

Страница 6: ...luids including air line anti icer system antifreeze compound or fluid film to accumulate on under or around acoustical mate rial or on any external surfaces of the air com pressor Wipe down using an...

Страница 7: ...codes or regula tions B DO NOT use air line anti icer systems in air lines supplying respirators or other breathing air utili zation equipment and DO NOT discharge air from these systems into unventi...

Страница 8: ...andling any ungrounded conductors 1 9 LIFTING A If the compressor is provided with a lifting bail then lift by the bail provided If no bail is provided then lift by sling Compressors to be air lifted...

Страница 9: ...a cles at floor level and transport and corner at minimum practical speeds N Make sure pallet mounted compressors are firmly bolted or otherwise secured to the pallet prior to attempting to forklift o...

Страница 10: ...10 BLANK PAGE...

Страница 11: ...roller panel is shown in Figure 2 1 The controller panel consists of Display Screen for displaying machine status START pad for machine startup STOP pad for stopping machine operation and for clearing...

Страница 12: ...the following steps 1 With the compressor running visually check that the fan rotation is correct 2 If it is incorrect change the direction of the fan motor by disconnecting power from the compressor...

Страница 13: ...ear on the display screen 3 If a different operating mode is desired use the arrow pads to navigate to the Mode parameter Press the ENTER pad to enter the Change Mode Navigate to the desired mode Auto...

Страница 14: ...14 BLANK PAGE...

Страница 15: ...Section 3 3 3 2 COMPRESSOR ADJUSTMENT PROCEDURES The following steps apply while Show Setting is indicated in the display The control parameter described in the display can be modified by the user Us...

Страница 16: ...ps the machine from being started more than four times an hour This secondary timer is disabled when a machine is configured for VSD motor control Drain Interval Mins Set interval in minutes between a...

Страница 17: ...Change Setting Load Delta Pressure Show Setting Unload Minutes Change Setting Unload Minutes Show Setting Drain Interval Mins Change Setting Drain Interval Mins Show Setting Drain Time Seconds Change...

Страница 18: ...rnished external remote control This may be wired to a remote switch timer or other controls to halt operation of the compressor as desired To enable remote control of the compressor 1 Wire the remote...

Страница 19: ...value 4 3 INDICATOR LED DESCRIPTION Four LED s on the WS Controller Panel provide indication of the general state of the machine Power On Indicator GREEN LED Lights whenever power is applied to the co...

Страница 20: ...mperature 2 Displays the current compressor temperature at temperature probe 2 Temperature 3 Displays the current compressor temperature at temperature probe 3 Dewpoint Temperature Displays the curren...

Страница 21: ...e display window This mode indicates that a machine problem has occurred causing the controller to shut down the machine until the condition is cleared After a fault condition has been resolved the fa...

Страница 22: ...layed when the compressor is delivering air at full rated capacity Unloading Displayed as the compressor is being unloaded automatically Remote Unloading Displayed as the compressor is being unloaded...

Страница 23: ...ufacturer Dryer Service Indicates a dryer is running while a malfunction is occurring Consult the dryer manual and or dryer manufacturer High Air Filter dP Indicates the air filter pressure differenti...

Страница 24: ...ressure at specified transducer A or B has exceeded the set high limit High Sump Pressure Compressor sump pressure has risen above the set limits High Temperature 1 3 The temperature at specified temp...

Страница 25: ...rter auxiliary contact failed to connect power to the starter UI Voltage Too High The voltage to the User Interface has risen above the set limit UI Voltage Too Low The voltage to the User Interface h...

Страница 26: ...26 BLANK PAGE...

Страница 27: ...c Check for parts damaged by heat or an elec trical short circuit usually apparent by discol oration or a burnt odor Should your problem persist after making the recommended check consult your nearest...

Страница 28: ...ton Release button Check wiring High Air Filter P Differential Pressure Across Inlet Filter High Replace filter Check inlet filter pressure switch High analog input AN0 through AN9 Sensor Pressure Tra...

Страница 29: ...er is cooling below the low dewpoint temperature setting Consult the dryer manual and or Sullair Factory Service Low Line Pressure Demand exceeds capacity Leaks in supply lines Reduce demands Increase...

Страница 30: ...ol Power Check line voltage and connections Replace Battery Controller I O backup battery is low Replace battery Separator dP High fault High Separator dP warning Pressure Differential Across Separato...

Страница 31: ...dead battery the time of day records will not work properly and loss of recent records could occur If recent records are lost due to an inoperative battery or other reason the controller will revert...

Страница 32: ...ule 4 Remove six screws from I O Control Module cover and remove cover 5 Locate the internal battery The battery is located near one end of the I O circuit board usually oriented towards the top 6 Rem...

Страница 33: ...5V Com PB 485C O J12 3 02250161 734 O Input T2 J13 3 02250161 734 O 5V Com PF 485 O J14 3 02250161 734 O Input T3 PF 485 O J15 10 02250161 737 O 5V Com PF 485C O J16 6 02250161 735 Rx O Tx O O 24V Sup...

Страница 34: ...34 BLANK PAGE...

Страница 35: ...he variable speed drive make sure that the front and cable covers are closed and fastened to prevent exposure to potential electrical fault condi tions Failure to observe this precaution could result...

Страница 36: ...heir voltage using a multimeter set to measure DC voltage Failure to follow the above precautions may cause death or severe injury CAUTION Do not perform any meggar or voltage with stand tests on any...

Страница 37: ...al but should be done by a quali fied electrician in compliance with OSHA National Electrical Code and or any other applicable State Federal and local elec trical codes concerning isolation switches f...

Страница 38: ...00 4 0 1 0 150 205 250 300MCM 2 0 200 261 350 2 x 4 0 3 0 250 300 400 2 x 250MCM 300MCM 300 385 700 2 x 300MCM 300MCM 350 460 1250 2 x 400MCM 400MCM Table 6 2 Cable and Fuse Sizes 575V Ratings _ UL re...

Страница 39: ...pper cables only 75 C or higher The minimum input line cable and line fuses must be sized in accordance with the rated input current of the unit See Table 6 1 and 6 2 Consistent with UL listing requir...

Страница 40: ...d Delta Pressure Change Setting Load Delta Pressure Show Setting VSD Setpoint Change Setting VSD Setpoint Show Setting Unload Minutes Change Setting Unload Minutes Show Setting Drain Interval Mins Cha...

Страница 41: ...ontrols The setpoint pressure is normally adjusted near the bottom of the load unload delta The compressor speed will be adjusted to maintain this pressure Most packages will allow adjustment of this...

Страница 42: ...possible causes and some likely solutions The controller monitors communications with the inverter and will display a fault message if these communications are broken The WS Controller will display a...

Страница 43: ...service V09 Undervoltage DC link voltage is less than the minimum safe operating voltage limit most probable cause supply volt age too low variable speed drive internal fault If there was a supply vol...

Страница 44: ...s fault the variable speed drive will automatically reload the parameter default settings Check all parameter settings after reset If the fault reoccurs contact Sullair service V24 Counter Fault Value...

Страница 45: ...r Fault This fault is disabled A display of this message indicates that the components or settings of the variable frequency drive have been changed Correct drive parameters need to be downloaded Cont...

Страница 46: ...correct contact Sullair service V56 PT100 Board This fault is disabled A display of this message indicates that the components or settings of the variable frequency drive have been changed Correct dr...

Страница 47: ...47 BLANK PAGE...

Страница 48: ...s LTD Princess Highway Hallam Victoria 3803 Australia Telephone 61 3 9796 4000 Fax 61 3 9703 8053 www championcompressors com au SULLAIR CORPORATION 3700 East Michigan Boulevard Michigan City Indiana...

Отзывы: