70970-UK-01
Document
INSTRUCTION MANUAL
Date
May 01 2016
Title of document
INSTRUCTION MANUAL and WARNINGS FOR USE XK 1
Revision
001
TO ENSURE YOUR USER INFORMATION IS UP TO DATE PLEASE DOWNLOAD THE LATEST VERSION OF THIS MANUAL FROM WWW.SUEX
Page 34 of 47
38.1 P
ROCEDURE TO FOLLOW IN THE EVENT THE CUT OFF DEVICE
IS TRIGGERED
In the event the cut off system triggers, IT IS IMPORTANT you proceed as follows:
1. Follow the ADV opening procedure;
2. Disconnect the motor battery power connector;
3. Remove the battery from the ADV;
4. Let the battery rest for at least 2 hours. This is the minimum time required, in this
case, for the battery to cool and return to awaiting charge conditions;
5. Connect the battery charge connector to the battery charger;
6. Charge following the instructions in the battery charger manual.
IMPORTANT NOTE!
Always remember that the ADV inevitably stops running when
the cut off device is triggered. This event is not hazardous to the
diver in any way since the dive was planned taking into account
that ADV use is not considered a safety device or rescue means.
SUEX
S.r.l. is not liable after the cut off system triggers, in any situation, in
hazardous situations or immersions where the driver (at his full risk) confided on
surfacing by using our manufactured underwater scooter.
Please remember that the ADV must be considered as an immersion aid and not
as a rescue vehicle.
39 L
ITHIUM ION BATTERY
,
SAFETY RECOMMENDATIONS
:
All the recommendations contained in this document must be strictly applied in order to
ensure a safe and optimal use of the battery.
Misuse of the battery may lead to overheat or ignite and cause serious injury. Make sure to
follow the safety rules listed below:
- Never short circuit the battery terminals;
- Do not open the battery;
- Do not reverse the polarity;
- Do not disassemble the battery;
- Do not subject the battery to excessive mechanical stresses;
- Do not expose the battery to water or condensation;
- Do not place the battery on or near fires, or other high temperature locations (>
70°C); Doing so may cause the battery to overheat or ignite. Using the battery in
this manner may also result in a loss of performance and a shortened life
expectancy;
- Immediately disconnect the battery if, during operation, battery emits an unusual
smell, feels hot, changes shape, or appears abnormal in any other way;
Contact SUEX if any of these problems are observed.