The CRC-1200 is a panel/wall  mounted controller dedicated to 
controlling the cold room and its various devices. 

The  controller  controls  the  defrost  in  the  system  based  on 
either an electrical heater where the compressor is stopped, or 
at  cycle  inversion  using  warm  gas  where  the  compressor 
keeps on working. 

It is also possible to select the interval between defrosts and a 
maximum time out after which the defrost is interrupted. The 
same probe which controls the defrost cycle is also used to 
control  the  evaporator  fans.Post  drip  and  condensor  fan 
control are amongst many other features in this contoller.

There  are  safety  features  which  include  shutting  down  the 
system  incase  of  a  fault  from  a  pressure  control  or  similar 
device.

Computer Connectivity over RS485 and Remote 
monitoring(Optional).

Single Operation Quick Freeze Mode(Press UP Key for 4 sec), 
Set system in quick freeze mode which is time based for that 
period  new  setpoint  will  be  lower  than  running  setpoint  and 
system will try to achieve that setpoint, after time period over 
set point will be normal setpoint.

Introduction

Features:

03

CRC1200

CRC1200

04

Get to Know Your Controller

Items included 

Lamp
Button

Reset
Button

Defrost
Button

Program Mode
Button

Up Button

Time / Down
Button

Set Button

Power ON/OFF
Button

LED
Indications

LCD
Display

7 Segment Display

Quick
Freeze

NO.

1.

2.

3.

4.

QTY

ITEMS

CONTROLLER

SENSOR 5 METER

CATALOGUE

SENSOR 3 METER

1

1

1

1

5.

6 X 25 SCREW

3

Содержание CRC 1200

Страница 1: ......

Страница 2: ...ressor function during Room probe failure 5 6 6 8 9 10 7 7 7 8 9 9 9 10 To set Evap Fan operation when compressor is off EVAP Wn COMP OFF 10 To set Evaporator Differential EVAP DIFFERENTIAL To set coi...

Страница 3: ...afety features which include shutting down the system incase of a fault from a pressure control or similar device Computer Connectivity over RS485 and Remote monitoring Optional Single Operation Quick...

Страница 4: ...o change Max Set Point parameter press the set key Use UP DOWN key to set desired value Once set at a particular value this will not allow set points to go above this value and below QUICK FREEZE SPse...

Страница 5: ...nge Min Max Fact Set 08 CRC1200 Sr No Parameter setting method Description of parameters and functions Parameter LCD Message ROOM PROBE CAL 07 Function To set room probe 1 calibration To change the Ro...

Страница 6: ...me for defrost water To change the Drip Time Dur parameter press the set key Use UP DOWN keys to set desired value During this period Compressor Evaporator Fan LSV relay and Heater will stay off so th...

Страница 7: ...ition To change Evap at Door Open parameter press the set key Range Min Max Fact Set Range Min Max Fact Set In time it may be possible that the display may be offset by a degree or so To compensate fo...

Страница 8: ...on To save system programming parameters To change Save Programming parameter press the set key 14 CRC1200 CRC1200 0 Min 45 Min 15 min Example If this parameter is set to 15 minutes and Defrost freque...

Страница 9: ...1 00 and 8 LEDs for indication 16X2 LCD Display For System Status Keypad 9 keys may change Rs485 Connectivity Modbus RTD Protocol Baud Rate 9600 N 8 1 Device ID 1 By Default Hot Key Optional Housing M...

Страница 10: ...use abrasive detergents petrol alcohol or solvents Controller Controller should be installed in a place protected by vibration water and corrosive gasses and where ambient temperature does not exceed...

Страница 11: ...advised of the possibility of such damages No part of this manual may be reproduced or transmitted in any form or by any means without the prior written permission of the company A S Controls Pvt Ltd...

Отзывы: