Model 506 (UC Ice Maker)

Model 506 (UC Ice Maker)

Installation & Maintenance

2-3

#3752200 - Revision B - May, 2006

Water Connection Requirements

Materials needed for installation:

1/4-in. O.D. copper tubing
1/4-in. outlet, saddle-type shut-off valve

(Part No. 4378392)

1/4-in. x 1/4-in. tube union

(Part No. 4378972)

These materials can be obtained locally or from your
FSP Parts Distributor by ordering Ice Maker Installation
Kit No. 978567, which includes 25 feet of copper tubing.
Do not use plastic tubing because it becomes brittle
with aging.  

Make sure the saddle valve complies with local plumb-
ing codes.  Do not use a self-piercing type or 3/16-inch
saddle valve because they reduce water flow and clog
more easily.

For proper operation, the ice maker should be connect-
ed to an active water supply line delivering cold water
at pressures between 20 and 120 pounds per square
inch.

 (See Figure 2-2)

Figure 2-2.  Water Connection Components

Do not install copper tubing in an area where
temperatures drop below freezing.  To do so
may result in water damage.

Installation of Line Tapping Device and/or Shut-off
Valve

1.  Select the point on an active cold water supply line

convenient to the unit where connection is to be
made.  A point on a vertical section of 1/2-in. or 3/4-
in. line leading to the kitchen sink is ideal.  If
installed on a horizontal line, place valve on top or
side of line; never on bottom. (This will keep water
away from the drill during installation and helps nor-
mal sediment from collecting in the valve.)  Turn off
the water supply and clear line of pressure.

2.  Provide a length of 1/4-in. O.D. copper tubing for

connecting the ice maker to the water supply.  To
determine the length, measure distance from the
unit to the connecting point on supply line, and add
approximately three feet to allow for connection to
the water valve in the unit.  Be sure both ends of
copper tubing are cut square.

3.  Drill a 1/8-in. hole in water supply line at point

selected for making connection.  Care must be
taken to drill a clean hole perpendicular to wall of
supply line.  Be sure electric drill is grounded, or
use a hand drill to avoid shock.

4.  Be sure the shut-off valve is in the OFF position.

Turn clockwise until the stem is seated.

5.  Assemble shut-off valve and pipe clamp and mount

it on the supply line.  The inlet tube of the shut-off
valve must extend through the rubber washer and
into the 1/8-in. hole drilled in the line.  Tighten the
packing nut.  Tighten the clamp screws just enough
for the rubber gasket to ensure a watertight seal.
Clamping too tightly may crush the copper tubing.

6.  Slip the compression nut, and then the sleeve, on

the end of the 1/4-in. tubing.  Insert the end of the
tube into the outlet end of the shut-off valve as far
as it will go, then screw the compression nut onto
the shut-off valve enough to get a watertight seal.
Place the other end in a sink drain or bucket.

7.  Turn on the main water supply.  Turn the handle on

the shut-off valve counterclockwise to open the
valve and flush the tubing until the water runs clear,
then close the valve. 

NOTE:

  

Make sure there is a vigorous flow of water

(volume and pressure).

8.  Bend the tubing to run it to the installation location.

Position the tubing so it can enter the access hole
located in the right rear of the ice maker cabinet.
The tubing will extend beyond the cabinet front
when the cabinet is pushed back into position.

Packing

Nut

Compression

Nut

Vertical

Cold Water

Pipe

Inlet

Tube

USE ONLY

1/4” COPPER

TUBE TO 

SHUT-OFF

VALVE

Shut-off

Valve

Outlet End

Compression

Sleeve

Inlet End

Rubber
Gasket

Pipe Clamp

Copper

Содержание Wolf 506UI

Страница 1: ...eral Information 2 Installation Information 4 Controls Operation 14 Component Access Removal 27 Troubleshooting Guide 40 Technical Data 44 Wiring Diagrams 47 subzero com 800 222 7820 506UI Service Man...

Страница 2: ...PM Central Time Monday through Friday IMPORTANT SAFETY INFORMATION Below are Product Safety Labels used in this manual The Signal Words used are WARNING or CAUTION When reviewing this manual please no...

Страница 3: ...Year TOTAL PRODUCT warranty parts and labor Five year LIMITED SEALED SYSTEM warranty sealed system parts only Warranty Details Total Product Parts includes but is not limited to the following Control...

Страница 4: ...nit will require an electrical branch circuit of 115 Volts 60 Hertz 1 Phase 15 Amp delayed action fuse or circuit breaker It is recommended that the ice maker is the only appli ance plugged into the r...

Страница 5: ...distance from the unit to the connecting point on supply line and add approximately three feet to allow for connection to the water valve in the unit Be sure both ends of copper tubing are cut square...

Страница 6: ...ressure activated high speed pump which will lift water from melting ice and fill cycles to a place where it can be disposed of The pump installs in the compartment below the ice maker storage bin and...

Страница 7: ...eplaced if the unit is to be operated later without a condensate pump Tape shunt to wall of unit compartment to avoid loss Run the discharge line from the pump directly to the available drain The FSP...

Страница 8: ...from side to side by placing a level across the top of the cabinet 10 If necessary the ice maker should be shimmed so that it is solid as well as level Use a hard perma nent material such as Masonite...

Страница 9: ...Spread the trim on one side and remove the door handle and top trim piece 4 Slide the metal panel out and replace with the new colored panel See Figure 2 13 5 Reassemble the door 6 Remove the screws...

Страница 10: ...vehicle where it will be operating while the RV is moving it is necessary to purchase and install a Water Deflector Kit Part No 702354 from your FSP parts Distributor The 702354 water deflector kit is...

Страница 11: ...etely drained replace drain plug 5 Pour 1 2 gallon approximately 2 liters of hot tap water into the water reservoir pan Turn the service control switch to the CLEAN position Allow the hot water to cir...

Страница 12: ...IQ UID CLEANING SOLUTION USE ONLY A CITRIC ACID BASED SOLUTION OR A COMBINATION OF CITRIC ACID AND PHOSPHORIC ACID BASED SOLUTION DO NOT USE MURATIC ACID OR ANY OTHER ACID NOT APPROVED FOR USE IN A FO...

Страница 13: ...sh or a round dust brush attach ment to a vacuum cleaner remove lint and dirt from the condenser fins 4 Use a vacuum cleaner to remove dirt from the bot tom of the unit compartment 5 Replace the lower...

Страница 14: ...dramatic pressure drop occurs as the low pressure cool liquid refrigerant leaves the small diameter capillary tube and enters the larger diameter evaporator tubing and the refrigerant begins to vapori...

Страница 15: ...tube During the later stages of the ICE MAKING cycle as the ice slab forms on the evaporator freezing plate some of the refrigerant passing through the evaporator will not evaporate into a gas but wi...

Страница 16: ...refrigerant that has accumulated in the accumulator tube up into the evaporator The warmed liquid refrigerant helps to evenly heat the evaporator plate so the ice slab releases quickly and evenly Eva...

Страница 17: ...em when the water supply has a low mineral content Ice Making Cycle In the water system See Figure 3 4 the water pump moves the water from the reservoir pan up to the dis tributor where it flows out o...

Страница 18: ...reservoir pan As the reservoir fills the mineral laden water from the previous ICE MAKING cycle is flushed out to the drain See Figure 3 9 Figure 3 8 Cutting Into Cubes Figure 3 7 Ice Slab Sliding of...

Страница 19: ...OFF CLEAN SERVICE SWITCH 115 VOLTS 60 HERTZ N L WATER PUMP CONDENSER FAN PLUG PRESSURE SWITCH CONDENSATE DRAIN PUMP START RELAY COMPRESSOR S R RECEPTACLE HOT GAS SOLENOID N C N C WATER VALVE SOLENOID...

Страница 20: ...the bin thermostat to the compressor See Figure 3 14 Power is supplied through the evaporator thermostat to the condenser fan and the water pump If an FSP condensate pump is installed on the unit powe...

Страница 21: ...evaporator temperature rises because of the hot gas flow and because the ice slab has slid off the evaporator thermostat switches the unit to the ICE MAKING cycle This cycling between the ICE MAKING...

Страница 22: ...n the bin is full of ice 2 1 6 3 ON OFF CLEAN SERVICE SWITCH 115 VOLTS 60 HERTZ N L WATER PUMP CONDENSER FAN START RELAY COMPRESSOR S R RECEPTACLE HOT GAS SOLENOID N C N C WATER VALVE SOLENOID EVAPORA...

Страница 23: ...NOID N C N C WATER VALVE SOLENOID EVAPORATOR THERMOSTAT 2 3 1 BIN THERMO STAT OVERLOAD TRANSFORMER 115 V 8 5 V DOOR SWITCH CUTTER GRID UNIT SHOWN WITH FSP CONDENSATE PUMP SERVICE SWITCH IN OFF POSITIO...

Страница 24: ...ration system does not operate during the CLEAN cycle 2 1 6 3 ON OFF CLEAN SERVICE SWITCH 115 VOLTS 60 HERTZ N L WATER PUMP CONDENSER FAN START RELAY COMPRESSOR S R RECEPTACLE HOT GAS SOLENOID N C N C...

Страница 25: ...um softener reduces frequency of Carbonates cleaning by 50 RECOMMENDATIONS Water softeners and polyphosphate feeders are not cure alls but do reduce and in some cases prevent scale buildup They are pa...

Страница 26: ...ECT ON ICEMAKER T D S 50 1000 ppm Cloudy Slow Cutting Temporary and Permanent or higher Refreezing Scale Buildup Chlorides 200 300 ppm Major Cause of Cloudy Ice Temporary and Permanent or higher Slow...

Страница 27: ...access to other components When following a component removal procedure it may be necessary to reference another component removal procedure listed earli er in this section NOTE Before continuing ple...

Страница 28: ...lt outward 7 Remove control panel components by first discon necting wire leads from component terminals See Figure 4 2 8 Extract screws that pass through the front face of the control panel and faste...

Страница 29: ...Then check across the terminals See Figure 4 4 If evaporator is cold If evaporator is warm To test method 2 1 Remove wire lead from terminal 6 on the service control switch disabling the water pump Se...

Страница 30: ...er The transformer has a 115 Volt AC primary coil with a secondary coil that produces 8 5 Volts at 2 Amps A special replacement service transformer is available from your FSP parts distributor with a...

Страница 31: ...he hinge pin on the other side Friction Door Catch The catch is located on the bottom of the escutcheon It can often be adjusted by adding washers under the catch If these does not correct the problem...

Страница 32: ...d should be replaced 6 Visually check the terminals insulators and frame They should all be free of mineral build up The insulators should not show any signs of melting If the terminals insulators or...

Страница 33: ...ttach a 120 volt test cord to the water pump plug the top two pins The pump should operate when power is supplied 2 Visually check the water pump plug and the socket on the rear bin wall They should b...

Страница 34: ...evaporator plate can be dropped for better access To drop 1 Though not necessary it is recommended that the bin door be removed for easier access 2 Remove the cutter grid assembly water reservoir pan...

Страница 35: ...ach of the small holes in the distributor must be unrestricted There is a built in water restrictor at the inlet end of the distributor The restrictor controls the amount of water running over the eva...

Страница 36: ...ot in place during operation warm air could be continually recirculated through the unit area resulting in inefficient operation and low quality ice To pull out the unit compartment 1 Remove the door...

Страница 37: ...screen in the water inlet To check 1 After removing the wire leads use an ohmmeter set on the R x 100 scale 2 Test across the terminals The ohmmeter should read approximately 250 ohms A flow washer in...

Страница 38: ...t on the R x 10K scale Check from each terminal C S and R to compressor housing The meter probe on the compressor housing should be placed on the grounding blade or in an area that is free of paint su...

Страница 39: ...is plunger must seat properly for efficient operation of the ice maker See Figure 4 25 If there is a small leak in the valve the outlet tube from the valve will feel cold and may frost up during the I...

Страница 40: ...tion to take to correct the problem Troubleshooting Guide Layout Page A Compressor won t run No ice in bin 6 3 B Compressor runs No ice in bin 6 3 C Compressor runs continuously bin full of ice 6 3 D...

Страница 41: ...set for thin cubes 2 Not enough water being circulated over evaporator 3 Evap thermostat out of calibration 1 Move to warmer area above 55 F 2 Connect water 3 Locate and repair 4 Replace relay 5 Move...

Страница 42: ...servoir pan 4 The water level is over the top of the drain tube in reservoir pan at beginning of ICEMAKING cycle 5 The water restrictor or the holes in the distributor are plugged 6 The water pump is...

Страница 43: ...ce block ing the passage of warm air from the unit compartment into the evaporator area 1 Ice thickness control set too high too thick of ice slab is forming 2 Overcharge of refrigerant in sealed syst...

Страница 44: ...the hot gas line at the front edge of the evaporator This shortens the defrost time Adjust range screw according to chart on unit thermostat bracket ICE PRODUCTION Lbs IN 24 HOURS 100 F 35 34 33 32 N...

Страница 45: ...ube to the hot gas line at the front edge of the evaporator This shortens the defrost time Adjust range screw according to chart on unit thermostat bracket ICE PRODUCTION Lbs IN 24 HOURS 100 F 35 34 3...

Страница 46: ...Storage Capacity 35 Lbs 4620 Cublets Electrical Requirements 115 Volts AC 50 60 Hertz Average Power Consumption 250 300 Watts Compressor 1 5 HP Piston Refrigerant Charge R 12 Prior to Serial 1181341...

Страница 47: ...VERLOAD TRANSFORMER 115 V 8 5 V DOOR SWITCH CUTTER GRID PLUG PRESSURE SWITCH CONDENSATE DRAIN PUMP EVAP THERMO BIN THERMO SERVICE SWITCH 1 3 3 2 1 6 2 BK Y W BK BK Y 0 0 BK BK BU BK Plug 115V 60 Hz 1...

Страница 48: ...8 5V R RED BK BLACK BL BLUE W WHITE Y YELLOW OR ORANGE BK W BLACK WHITE TRACER G Y GREEN YELLOW TRACER COLOR CHART Connector Screw Connector Closed End Disconnect Terminal Permanent Connection Plug Co...

Страница 49: ...on B May 2006 1 6 Service Switch Water Pump Water Pump CLEAN Cycle L N 2 3 2 1 1 6 Service Switch Water Pump L N Water Pump ICE MAKING Cycle Bin Thermostat Evaporator Thermostat Service Switch 2 3 2 1...

Страница 50: ...h gravity drain or non FSP pump Shunt in receptacle 2 3 2 3 L N Bin Thermostat Evaporator Thermostat NC Receptacle Hot Gas Solenoid Pressure Switch FSP Condensate Drain Pump Hot Gas Valve Solenoid Uni...

Страница 51: ...t NC Receptacle Water Solenoid Pressure Switch FSP Condensate Drain Pump Water Valve Solenoid Units with FSP condensate drain Valve Service Switch 2 3 L Bin Thermostat Service Switch N Overload Compre...

Страница 52: ...n Light 2 3 L Service Switch 8 5 V 115V Transformer N Cutter Grid Cutter Grid 2 3 2 3 L N Bin Thermostat Evaporator Thermostat Receptacle FSP Condensate Drain Pump Service Switch Drain Pump FSP Conden...

Отзывы: