Page 16
Theory of Operation
Model 506 (UC Ice Maker)
Model 506 (UC Ice Maker)
3-4
#3752200 - Revision B - May, 2006
Refrigeration Flow - Harvest Cycle
the hot gas valve opens, allowing high pressure refrigerant gas to
bypass the condenser and flow through the condenser accumulating tube. The hot gas pushes the liquid refrigerant
that has accumulated in the accumulator tube up into the evaporator. The warmed liquid refrigerant helps to evenly
heat the evaporator plate so the ice slab releases quickly and evenly.
Evaporator
Accumulator
Capillary Tube
Suction
Tube
Compressor
Drier
Condenser
Condenser
Accumulating
Tube
Hot Gas
Valve
High Pressure Refrigerant Gas
Warm Liquid Refrigerant
Low Pressure Refrigerant Gas
Path of Warm Liquid
Refrigerant Pushed
by High Pressure
Refrigerant Gas
Heat
Exchanger
Figure 3-3. Refrigeration System